Home > hansgrohe > hansgrohe 24240XXX Shower Column Including Thermostat Instruction Manual

hansgrohe 24240XXX Shower Column Including Thermostat Instruction Manual

English  
(1 MPa = 10 bar = 147 PSI)  
max. 60°C  
Safety Notes  
Hot water temperature:  
Gloves should be worn during installation to prevent crushing and cutting  
injuries.  
The product may only be used for bathing, hygienic and body cleaning  
purposes.  
The arm of the shower head is intended only to hold the shower head. Do not  
load it down with other objects!  
Centre distance:  
Connections G 1/2:  
Thermal disinfection:  
150 12 mm  
cold right - hot left  
70°C / 4 min  
• Safety against backflow  
• The product is exclusively designed for drinking water!  
Children as well as adults with physical, mental and/or sensoric impairments  
must not use this product without proper supervision. Persons under the influence  
of alcohol or drugs are prohibited from using this product.  
Do not allow the streams of the shower touch sensitive body parts (such as your  
eyes). An adequate distance must be kept between the shower and you.  
The product may not be used as a holding handle. A separate handle must be  
installed.  
Symbol description  
Do not use silicone containing acetic acid!  
Safety Function (see page 35)  
The desired maximum temperature for example max. 42°C can be pre-set thanks to  
the safety function.  
The hot and cold supplies must be of equal pressures.  
Adjustment (see page 35)  
Installation Instructions  
After the installation, the output temperature of the thermostat must be checked. A  
correction is necessary if the temperature measured at the output differs from the  
temperature set on the thermostat.  
• Prior to installation, inspect the product for transport damages. After it has been  
installed, no transport or surface damage will be honoured.  
• The pipes and the fixture must be installed, flushed and tested as per the  
applicable standards.  
Maintenance (see page 42)  
• The plumbing codes applicable in the respective countries must be observed.  
• The installation dimensions stated in these installation instructions are ideal for  
people of approximately 1800 mm in body height. The dimensions can be  
altered if required. In this case, pay attention to the fact that a change of  
installation height will also change the minimum height, and that the altered  
mounting dimensions must be taken into consideration.  
• The check valves must be checked regularly according to EN 806-5 in accord-  
ance with national or regional regulations (at least once a year).  
• To guarantee the smooth running of the thermostat, it is necessary from time to  
time to turn the thermostat from total hot to total cold.  
Dimensions (see page 37)  
• During installation of the product by qualified trained personnel, make sure that  
the entire fastening surface is even and smooth (no protruding seams or tile  
offset), that the finish of the wall is suitable to apply the product and has no weak  
points.  
• The premounted dirt collection screen must be used to prevent dirt from entering  
through the pipes. Dirt entering can affect the function and/or lead to damage to  
the functional components of the fitting. Hansgrohe will not be held liable for any  
resulting damage.  
Flow diagram (see page 37)  
Overhead shower  
Hand shower  
Spare parts (see page 40)  
XXX = Colors  
000 = Chrome Plated  
140 = Brushed Bronze  
670 = Matt Black  
• The product is not designed to be used with steam baths!  
• If required, the bottom part of the pipe between the fixture and the shower head  
can be shortened with a fine-toothed saw.  
700 = Matt White  
Special accessories (order as an extra)  
Special information for UK  
If installing this product with a pump, please be aware that it has to have negative  
tile-matching-disk #94517000 (see page 40)  
head switching. This product will not function with a positive head pump.  
Cleaning (see page 38)  
Technical Data  
Operating pressure:  
24240XXX Recommended operating pressure:  
24241XXX Recommended operating pressure:  
Test pressure:  
Operation (see page 36)  
max. 1 MPa  
0,13 - 0,5 MPa  
0,17 - 0,5 MPa  
1,6 MPa  
To empty the overhead shower after use, hold it in a slightly inclined position.  
Fault  
Insufficient water  
Cause  
Remedy  
- Supply pressure inadequate  
- Check water pressure (If a pump has been installed  
check to see if the pump is working).  
- Clean filter in front of the mixer and on the MTC-ther-  
mo cartridge  
-
R
e
g
u
l
a
t
o
r
l
t
e
r
d
i
r
t
y
- filter insert shower dirty  
- Clean filter insert between shower and hose  
Crossflow, hot water being forced into cold water pipe, - Backflow preventers dirty or leaking  
or vice versa, when mixer is closed  
- Clean backflow preventers, exchange if necessary  
Spout temperature does not correspond with tempera- - Thermostat has not been adjusted  
- Adjust thermostat  
ture set  
- Hot water temperature too low  
- thermo cartridge calcified  
- Spring defective  
- Increase hot water temperature to 42 °C to 60 °C  
- Exchange thermo cartridge  
- Clean spring and/or button, exchange if necessary  
Temperature regulation not possible  
Safety stop button not operating  
- Button calcified  
Instantaneous heater didn't work with thermostat  
Shower drips continuously  
- Filters are dirty  
- check valve hasn't moved back  
- Dirt or sedimentation on valve seat, shut-off unit  
damaged  
- Clean the filter / exchange filter  
- Exchange check valves  
- Exchange shut-off unit  
Assembly (see page 33)  
4
GeneralDetails
Namehansgrohe 24240XXX Shower Column Including Thermostat Instruction Manual
Makehansgrohe
LanguageEnglish
FiletypePDF (Download)
File size14.05 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
hansgrohe Ecostat 1001 SL Shower Thermostat Instruction Manual
hansgrohe Ecostat 1001 SL Shower Thermostat Instruction Manual
hansgrohe 15384XXX RainSelect Thermostat Instruction Manual
hansgrohe 15384XXX RainSelect Thermostat Instruction Manual
hansgrohe AXOR CARLTON Thermostat Mixer Instruction Manual
hansgrohe AXOR CARLTON Thermostat Mixer Instruction Manual
hansgrohe AXOR STARCK X Concealed Thermostat with Shut Off Valve Instruction Manual
hansgrohe AXOR STARCK X Concealed Thermostat with Shut Off Valve Instruction Manual
hansgrohe AXOR URQUIOLA Concealed Thermostat with Shut Off Valve Instruction Manual
hansgrohe AXOR URQUIOLA Concealed Thermostat with Shut Off Valve Instruction Manual
hansgrohe AXOR UNO2 Concealed Thermostat with Shut Off Valve Instruction Manual
hansgrohe AXOR UNO2 Concealed Thermostat with Shut Off Valve Instruction Manual
Hansgrohe 13125000 Ecostat E Wall Mounted Shower Thermostat Instruction Manual
Hansgrohe 13125000 Ecostat E Wall Mounted Shower Thermostat Instruction Manual
hansgrohe AXOR STARCK Concealed Thermostat with Shut Off Valve Instruction Manual
hansgrohe AXOR STARCK Concealed Thermostat with Shut Off Valve Instruction Manual
hansgrohe 15754000 Metris Classic Ecostat Classic High Flow Thermostat Instruction Manual
hansgrohe 15754000 Metris Classic Ecostat Classic High Flow Thermostat Instruction Manual
hansgrohe 15763003 Shower Select Thermostat Instruction Manual
hansgrohe 15763003 Shower Select Thermostat Instruction Manual

hansgrohe 24240XXX Shower Column Including Thermostat Instruction Manual