Glow-Worm SRT 50-2 Climastat Select Programmable Room Thermostat User Manual

Ct: Room temperature control (fac-  
tory setting)  
r1...r8: Remote control (only possi-  
ble in conjunction with a compatible  
system control/with a communica-  
tion unit)  
installation room must always be fully  
open.  
> Pass all of the instructions and docu-  
mentation for the product to the end  
user for safe-keeping.  
5.4  
Installation  
5
For the competent  
person  
Fault  
Cause  
Measure  
Faults in the control type for the remote  
control  
5.4.1 Electrical installation  
The product must be installed by a quali-  
fied competent person while complying  
with the existing regulations, rules and  
directives.  
Communica- Ensure that  
tion fault  
between the  
control and  
the gateway. contact a  
competent  
and  
flash.  
Note  
the gateway  
is operating.  
Otherwise,  
> Only qualified electricians  
may carry out the electrical  
installation.  
6
Technical data  
> Press the rotary knob to confirm the  
setting.  
5.1  
Notes on the documentation  
SRT 50/2  
> The maximum length of the  
eBUS cable is 125 m  
> Connection cables with  
230 V and eBUS cables  
must be routed separately  
as of a length of 10 m.  
> The jumper between termi-  
nals RT and 24V on the  
plug for the boiler’s PCB  
must not be removed.  
Condition: The product is set to the control  
type for room temperature control  
> Turn the rotary knob to activate or  
deactivate the product’s domestic hot  
water function.  
person.  
Product dimensions,  
height  
97 mm  
97 mm  
31 mm  
5.1.1 Observing other applicable  
documents  
4.4  
Caring for the product  
Product dimensions,  
width  
> Clean the casing with a damp cloth and  
a little solventfree soap.  
> Do not use sprays, scouring agents,  
detergents, solvents or cleaning agents  
that contain chlorine.  
> Always observe all the operating and  
installation instructions included with  
the system components.  
Product dimensions,  
depth  
− The domestic hot water function  
must be activated before you can  
set the domestic hot water tem-  
perature on the product (→ Chap-  
ter 4.2.2).  
¬ off (domestic hot water function  
deactivated = factory setting) or  
on (activated) flashes in the dis-  
play.  
Maximum permitted envi- 50 °C  
ronmental temperature  
5.1.2 Storing documents  
> Pass these instructions and all other  
applicable documents on to the end  
user.  
Temperature for the ball  
75 °C  
4.5  
Decommissioning  
pressure  
test  
> Switch off the power supply to the con-  
nected boiler.  
> Check that the boiler is voltage-free.  
> Have a competent person decommis-  
sion the product.  
Power consumption  
Rated voltage  
240 mW  
24 VDC ±10%  
330 V  
5.2  
Requirements for the  
installation site  
4.6  
Recycling and disposal  
> Press the rotary knob to confirm the  
setting.  
Rated surge voltage  
Rated current  
> The competent person who installed  
your product is responsible for the dis-  
posal of the packaging.  
eBUS  
B
< 50 mA  
2
Condition: The outdoor temperature sensor  
Pollution degree  
is installed  
Connection cables, min.  
cross-section  
2 x  
0,75 ...1,5 mm2  
B
4
3.5  
3
2.5  
2
1.8  
90  
80  
70  
60  
50  
40  
30  
20  
A
If the product is labelled with this  
mark:  
Protection class  
IP rating  
III  
1.5  
1.2  
1.0  
0.8  
0.6  
IP 20  
V
> In this case, do not dispose of the  
product with the household waste.  
> Instead, hand in the product to a col-  
lection centre for waste electrical or  
electronic equipment.  
Control class in accord-  
ance with ErP  
0.4  
> Connect an eBUS cable to the prod-  
uct’s eBUS connection.  
> Install the product as shown.  
Contribution to the sea-  
sonal room-heating  
energy efficiency ηs  
3.0 %  
0.2  
0.1  
5.3  
Set-up  
> Connect the eBUS cable to the eBUS  
connection for the control on the boiler  
(→ Instructions for the boiler).  
> Re-establish the power supply to the  
connected boiler.  
15  
10  
5
0
-5  
-10  
-15 -20  
A
4.7  
Guarantee and customer  
service  
5.3.1 Opening the housing  
A Outside temperature [°C]  
B Target flow temperature [°C]  
> On the underside of the product, care-  
fully push the latching lug inwards.  
− Flat-blade screwdriver  
> Swivel the front half of the housing  
upwards.  
> Remove the front half of the housing  
upwards from the rear half of the hous-  
ing.  
4.7.1 Guarantee  
> Turn the rotary knob to set the heat  
curve.  
You can request information on the manu-  
facturer’s guarantee from the contact  
address provided on the back page of this  
document.  
5.5  
Start-up  
¬ The value that is currently set  
(factory setting: 1.2) is shown in  
the display.  
> Switch the boiler on.  
> Open all of the radiator valves in the  
room in which the room temperature  
control is located.  
> Turn the rotary knob to change the  
value.  
4.7.2 Customer service  
The contact details for our customer ser-  
vice are provided on the back page or on  
our website.  
> Press the rotary knob to confirm the  
setting.  
5.5.1 Setting the control type and  
parameter  
5.3.2 Mounting the product on  
the wall  
Condition: The control type (room tem-  
perature control/remote control) was not  
previously changed.  
> Open the housing.  
> Position the rear half of the housing on  
the wall.  
Note  
The product is set to the control  
type for room temperature control  
at the factory and, in this setting,  
several operating parameters of  
the heating system can be set.  
There is an option to configure the  
product as a remote control if a  
compatible system control or a  
communication unit takes on the  
control function.  
¬ The basic display is shown.  
Condition: The control type (room tem-  
perature control/remote control) was pre-  
viously changed.  
> Mark the position of the two drill holes  
through the two mounting holes.  
> Drill the holes for the fixing screws.  
> Install the product’s electrics. (→ Chap-  
ter 5.4.1)  
> Secure the rear half of the housing to  
the wall using suitable wall plugs and  
screws.  
> Secure the front half of the housing to  
the rear half of the housing in such a  
way that the latching lug audibly clicks  
onto the underside of the product.  
¬ rSEt is shown in the display.  
> If rSEt is shown in the display, restart  
the boiler.  
5.5.2 Checking the operation  
> Press and hold the rotary knob for at  
least 10 seconds to open the installa-  
tion menu.  
> Check that the installation is operating  
correctly.  
> Check all of the control and safety ele-  
ments, along with their settings and  
operating mode.  
¬
is displayed.  
¬ You are requested to enter the  
installer access code.  
5.5.3 Handing the product over to  
the end user  
> Turn the rotary knob until 96 is shown  
in the display.  
> Press the rotary knob to confirm the  
entry.  
> Turn the rotary knob to set the required  
control type for the product:  
> Inform the end user how to handle the  
product. Answer any questions the end  
user may have.  
> Point out to the end user that all of the  
radiator thermostats in the product’s  
GeneralDetails
NameGlow-Worm SRT 50-2 Climastat Select Programmable Room Thermostat User Manual
MakeGlow-Worm
LanguageEnglish
FiletypePDF (Download)
File size0.18 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

Glow-Worm SRT 50-2 Climastat Select Programmable Room Thermostat User Manual