Home > GLOBAL > GLOBAL WIFI Digital Heating Thermostat User Manual

GLOBAL WIFI Digital Heating Thermostat User Manual

temperature of external sensor, thermostat will  
disconnect relay,turn off load)  
setting  
3. Turn off thermostat, long press for 3-5 seconds to enter into advanced setting  
A5  
A6  
Children lock setting  
Limit value of high 1. 35℃-70℃  
temperature for external 2. Under 35℃, screen display【--】, high  
sensor temperature protection was canceled  
0:half lock  
1:full lock  
0
1 Confirm key: use it with  
2 Only short press it to set time  
key  
C
45℃  
3 Turn on thermostat,long press it for 3-5seconds to holiday mode setting. Appear  
OFF, press  
or  
change to ON,then press  
to confirm opening holiday mode  
Limit value of low 1. 1-10℃  
1 Decrease key  
B
temperature for external 2. Exceed 10℃, screen display【--】, Low  
A7  
5℃  
2 Long press to lock /unlock  
1 Increase key :  
sensor(anti-freeze  
protection)  
temperature protection was canceled.  
D
Setting  
temperature 1-10℃  
2 Long press to inquire external sensor temperature  
A8  
A9  
5℃  
lowest limit  
Setting  
3 In the Auto model, press  
or  
enter to temporary manual mode  
temperature 20-70℃  
Programmable  
5+2 (factory default),6+1 and 7 models 6 times period setting for user choose. In the advanced options  
35℃  
highest Limit  
0:Close descaling function  
0:Close  
descaling  
function  
choose model of you need, under power on state, long press for 3-5 seconds enter into programming  
1:Open descaling function(valve is continuously  
closed over 100 hours , it will be opened for 3  
minutes automatically)  
AA  
AB  
Descaling function  
mode setting, then short press  
choose: hour,minute, time period, and press  
and  
to adjust  
data, finished setting, about 10 seconds will automatic save and exist.  
Power with memory 0:Power with memory function  
0:Power with  
memory  
function  
1:Shutdown power after power off  
2:Shutdown power after power on  
function  
Weekly  
programming 0: 5+2  
Wake up  
Out door  
Back home  
Out door  
Back home  
Sleep  
AC  
AD  
selection  
1: 6+1  
0: 5+2  
11:30  
13:30  
17:00  
22:00  
6:00 20℃ 8:00 15℃  
15℃  
15℃  
15℃  
15℃  
2: 7  
The optimum comfort temperature is 18℃-22℃.  
Restore factory defaults  
Display A o, press  
key whole show  
1: 00:00-23:30  
2: 00: 00 press”  
night light function  
1: 00:00-23:30  
Advanced options  
Time setting of turn on  
AE  
and display--,it means cancel  
18:00  
6:00  
Under turn off state, long press  
From A1 to AD, short press  
for 3-5 seconds to access advanced setting.  
night light (HY311 model)  
to choose the option, and adjust data by  
,
, short press  
to switch  
next option.Remain about 5 seconds after finish setting will quit setting.  
Time setting of turn off  
AF  
NO  
Setting Options  
Measure Temperature  
Calibration  
Data Setting Function  
Factory Default  
0.5℃ Accuracy  
Calibration  
night light (HY311 model)  
A1  
-9-+9℃  
Return difference : limit valve of external sensor is 45℃ for factory default (A6),value of external  
sensor control return difference (A3) is 2. when temperature rise to 45℃,then relay stop working and will  
remind high temperature production alarm. If temperature decline to 43℃relay continue to work and  
heating alarm will be relieved. (it can be operated ,only when indoor temperature is lower than setting  
temperature )  
Temperature  
control 0.5-2.5℃  
A2  
A3  
1℃  
return difference setting  
External sensors limit 1-9℃  
temperature  
control  
2℃  
Sensor fault display:please choose correct working way of built-in and external sensor, if choose  
wrongly or sensor fault (breakdown), “E1” or “E2” will be displayed on the screen. Thermostat will stop  
heating until the fault is eliminated  
return difference  
Options of sensor control N1:Built-in sensor (high temperature protection  
close)  
Warranty:  
N2:External sensor (high temperature protection  
close)  
We offer the warranty of 18 months, from the sales day. The products of our company can have lifetime  
warranty ,if it is not the quality problems, or beyond the warranty period, we will charge for the after-sale  
service.  
A4  
NI  
N3:Built-in sensor control temperature ,external  
sensor limit temperature (external sensor detect  
the temperature is higher than highest  
GeneralDetails
NameGLOBAL WIFI Digital Heating Thermostat User Manual
MakeGLOBAL
LanguageEnglish
FiletypePDF (Download)
File size0.17 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GLOBAL WiFi Heating Thermostat User Manual
GLOBAL WiFi Heating Thermostat User Manual
GLOBAL HY09RF WIFI Wireless Thermostat User Manual
GLOBAL HY09RF WIFI Wireless Thermostat User Manual
GLOBAL CEG Series Convector with Thermostat Instruction Manual
GLOBAL CEG Series Convector with Thermostat Instruction Manual
GLOBAL Digital Heating Thermostat User Manual