Home > GENERAL LIFE > GENERAL LIFE 300S RF Wireless Room Thermostat User Manual

GENERAL LIFE 300S RF Wireless Room Thermostat User Manual

WARRANTY CONDITIONS  
1-The warranty period starts from the invoice date and warranted against  
manufacturing defectsfor 5 years.  
When settingis done, bypressingSettingsbutton, Economymode can be set.  
Economy Mode's “ ” temperature value would appear and temperature for  
EconomyMode can be adjusted bypressingUp” and “Downbuttons.  
PressingSettingsbutton for 3 seconds again would close “Settingsscreen.  
Manual mode temperature can be set by pressing “Up” and “Down” buttons while  
on home screen. When “Up” or “Down” buttons are pressed Room Thermostat will  
be seton Manual Mode.  
TPIROOMTHERMOSTATCOOLINGMODEWORKINGGRAPHIC  
WARRANTY CERTIFICATE  
TEMPERATURE (ºC)  
Desired Temperature  
TPI Room Thermostat  
30  
2-Devices and apparatus are delivered to the customer in working condition in  
our company. On-sitecommissioning is subjectto aservice fee.  
3-The repair of the devices and apparatus covered by the warranty is carried  
out in our company factory and should send by contracted transportation  
company. In on-site services, the transportation and accommodation  
expenses of the service personnel belong to the customer. The shift fee during  
transportation is added to theservice feeand collectedin advance.  
4-The maintenance of devices and apparatus is done in our company. For the  
maintenance of the devices and apparatus, the round travel fares belongs to  
thecustomer.  
5-In case of malfunctioning of the devices and apparatus whose warranty  
period continues, it is tested in our company whether the malfunction is  
caused by a customer or manufacturer fault, and it is reported with a report  
issued byour company.  
6-In case of detection of manufacturer-induced errors of devices and  
apparatus whose warranty period continues, the customer can request a  
replacement or repair of the devices and apparatus at full expense by the  
manufacturer, unless it's higher than theproduct's price.  
7-In the event that the faults of the devices and apparatus whose warranty  
period continues are determined as caused by the customer, all expenses  
would be belong to thecustomer.  
8-Customers should be aware of damages (if there is any) of product and warn  
manufacturer since the day warranty duration starts.If customer do not warn  
manufacturerwithknowledge of damage, customerlose therights of article 6.  
9-Malfunctions resulting from the use of devices and apparatus contrary to the  
mattersstatedin theUserManualarenot covered bythewarranty.  
10-Devices and their apparatus are out of warranty if they are beaten, broken or  
scratchedbythecustomer.  
11-Damages resulting from the use of devices and apparatus belonging to  
other brands and models without the approval of the manufacturer are not  
covered bythewarranty.  
12-Battery leakage and errors due to rust, oxidation and liquid contact by  
working in acidic/ humid environments arenot covered bythewarranty.  
13-When the product is not used for a long period (more than 15 days), remove  
thebatteries. Otherwise, malfunctions thatwilloccur areout of warranty.  
14-Damages that may occur during the transportation of devices and  
apparatus are not covered by the warranty. Customers can take  
transportation insurance.  
15-Damages caused by mains voltage / faulty electrical installation are not  
covered bythewarranty.  
16-Devices and apparatuses are out of warranty for malfunctions caused by  
forcemajeuresuch asre, flood, earthquakeetc.  
17-All of the devices and apparatuses, including all their parts, are under the  
warrantyof our company.  
18-In case of malfunction of the devices and apparatuses within the warranty  
period, the time spent during repairment period is added to the warranty period.  
The repair period of the product cannot exceed 20 working days. This period  
starts from the date of notification to the service station of the malfunction  
related to the product or, in the absence of a service station, to the seller, dealer,  
agency, representative, importer or manufacturer of the product. Consumer  
can report the problem by; phone, fax, e-mail, registered and reply paid letter or  
a similar way. However, in case of a conflict, responsibility of prove is belong to  
the customer. If the malfunction of the product is not repaired within 20  
working days, the manufacturer-producer or importer; has to allocate another  
product with similar features to the use of the consumer until the repair of the  
product is completed,  
Manufacturer  
Title: ISIPARK İÇ DIŞ TİC. A.Ş.  
Adsress: Fatih Mah. 1188 Sk. No:13/A Sarnıç  
Gaziemir İzmir-TÜRKİYE  
Tel: +90 (232) 457 99 50  
Fax: +90 (232) 457 91 22  
E-Mail: generallife@generallife.com.tr  
Authorised Signatory:  
23  
Youcanpressthe"Mode"buttontoswitchtoothermodes.  
PROGRAMMINGMODE  
You maychoose which mode will be active, individually for each hour of the daywith  
programming mode. Weekly program mode includes 2 active modes. Those are  
Comfort Mode “  
5
Time  
” and EconomyMode “  
”.  
Company Stamp:  
In order to arrange the weekly program ''Programming” button needs to be  
pressedfor 3 seconds.  
On the screen there will be icons for the day which wants to be programmed,  
hours of thedayand activemode.  
“By pressingModebutton, chosen mode for thatspecifichour maybe changed.  
By pressingthe up or down button, youcan scrollthroughthe hours of the dayand  
programaccordingto theactivemode.  
Press the “Setting” button to change the day of the week while making a weekly  
program.  
After setting a weekly program press the ''Programming'' button for 3 seconds to  
saveit.  
Your Room Thermostat sends the last status signal to the Receiverevery6 minutes.  
Thus, yourRoom Thermostat and Receiverwork synchronously. If the signal cannot  
reach to the Receiver from the Room Thermostat for 22 minutes, it perceives that  
the connection is broken and stops the heating/cooling operation for safety  
reasons. Likewise, in cases where the electricity comes back after a power failure,  
the Receiver do not operate the heating/cooling unit until 'operate' signal reaches  
fromtheRoom Thermostat.  
However, in this case, if the Room Thermostat continues to operate normally, it will  
continue to work properly without any need for intervention since it sends a status  
signal to theReceiverevery10minutes.  
Product  
Type: Digital Room Thermostat  
Brand: GENERAL Life  
Model: THERMA 300S RF  
Guarantee Period: 5 Years  
Max. Time to Repair: 20 Days  
Banderole and Serial Number:  
WHATTOKNOWABOUTTPIROOMTHERMOSTAT  
TPIROOMTHERMOSTATWORKINGLOGIC  
If the placement of the TPI Room Thermostats is changed, the learning process  
willrestart. The learning processshould be consideredas7 days.  
Your Room Thermostat works with the TPI algorithm. Room Thermostats using TPI  
technology predict when the temperature of your home will rise above or below the  
set temperature and turn the heating / cooling unit on and off accordingly. This  
ensures that your home stays at the temperature you set without maximum  
deviationsup and down.  
If the TPI Room Thermostats arede-energized(battery replacement), the learning  
processwillrestart. The learning processshould be consideredas7 days.  
FREQUENTLY ASKEDQUESTIONS  
IsmyRoom Thermostatcompatible withmyheating/cooling unit?  
Whatis TPI?  
TPI technology is designed to ensure that you get the best possible energy  
efficiency from your heating / cooling system. It measures and applies the best  
possible timings to deliverand maintain yourhome atthesettemperaturelevel.  
If your heating / cooling unit has on-off connections, your Room Thermostat is  
compatible. You can find information about your heating / cooling unit from your  
heating / cooling unit operating manual or fromyourheating / cooling unit service.  
How does TPIwork?  
How willIconnect myheating/cooling unit withmy Receiver?  
Thanks to the advanced artificial intelligence technology found in the software, it  
adapts to the temperature change of the environment in which it is located. By  
creating a general temperature map of your home, it learns how long it takes to  
reach the desired room temperature and how to maintain this temperature. In this  
way, it provides minimum energy consumption by calculating how long your  
heating/ cooling unit should workfor.  
We recommend that the connection between the Receiver and heating/cooling unit  
should be made byprofessionally qualified persons.  
2x0.75mmcableis sufficientfor theReceiverheating/cooling unit connection.  
Connect one end of the cable pair to the room thermostat connection terminals  
statedin theuser manual of yourheating/cooling unit.  
Connect the other end of the cable pair to COM and NO inputs of the terminal inside  
theReceiverasshown in the"RECEIVERWIRINGDIAGRAM" section.  
The directionof thecableends does not matter.  
Vendor  
Title:  
a
Whatis thedifference?  
In non-TPI room thermostats, the heating  
/
cooling unit works and stops  
Address:  
continuously until it exceeds the set temperature value. If the set temperature  
drops below a certain amount, the heating / cooling unit will work again. This  
creates greater temperature fluctuations and less energy control. TPI Room  
Thermostats, on the other hand, provide higher savings and comfort compared to  
On/Off room thermostatswiththeadvantagesithas.  
DECLARATIONOFCONFORMITY  
Tel:  
E-Mail:  
Fax:  
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which Head Office  
and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç - Gaziemir -  
İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its  
specificationsbelow is coveredbytheprovisionsof thementioned directive.  
Invoice Date and Number:  
Delivery Time and Place:  
Authorised Signatory:  
Company Stamp:  
HeatingMode  
Brand  
: GENERAL Life  
Your room thermostat takes the average room temperature of last 40 seconds as  
basis. With the TPI algorithm in the product by creating a general temperature map  
of your home, it learns how long it takes to reach the desired room temperature and  
how this temperature is maintained. Thus, it ensures that the room temperature  
remainswithin acertain range.  
ProductName : THERMA 300S RF  
ProductType : Digital Room Thermostat  
Compatible Directives:  
Radio and Telecommunications TerminalEquipmentRegulation  
2014/53/EU(ETSI EN301489-1 V2.2.3(2019-11),  
ETSI EN301489-17 V3.2.4(2020-09), EN300220-1V3.1.1,  
EN300220-2V3.2.1(2018-06), EN62479:2010, EN62368-1:2014+A11:2017)  
Electromagnetic Compatibility Regulation 2014/30/EU  
(ETSI EN301489-1 V2.2.3, ETSI EN301489-3 V2.1.1)  
Low Voltage Directive2014/35/EU(EN60730-2-9)  
Additional Information: The mentioned product can be used with heating/cooling  
units with on / off output and compliance with the directives only covers the  
product. ISIPARK is not responsible for the entire system's compliance with the  
directives. This statement is not valid if changes are made to the product without  
our approval.  
TPIROOMTHERMOSTATHEATINGMODEWORKINGGRAPHIC  
Product  
TEMPERATURE (ºC)  
Desired Temperature  
TPI Room Thermostat  
Type: Digital Room Thermostat  
Brand: GENERAL Life  
STAMP  
30  
Model: THERMA 300S RF  
19-Although theconsumer uses his/her repairrights,  
-If the product breaks down for 4 times in a year or 6 times in warranty duration  
and these problems effects main purpose of the product. (starting from  
delivery timeduring warranty.)  
23  
-Exceeding themaximum timerequired for repair,  
-In the event that the service station is not available, if it is determined that the  
repair of the defect is not possible with the report prepared (in order) by one of  
the seller, dealer, agency, representative, importer or manufacturer, a refund or  
apricediscount attherateof defectcan be requested.  
Time  
5
CoolingMode  
20-The customer can make complaints and appeals to consumer courts or  
consumer arbitrationcommittees.  
21-The warranty document must be kept by the customer during the warranty  
period. If the document is lost, a second document will not be issued. In case of  
loss, repairand replacementof devicesand apparatuswill be made for afee.  
Your room thermostat takes the average room temperature of last 40 seconds as  
basis. With the TPI algorithm in the product by creating a general temperature map  
of your home, it learns how long it takes to reach the desired room temperature and  
how this temperature is maintained. Thus, it ensures that the room temperature  
remainswithin acertain range.  
Isıpark reserves the rights of changing product specifications and user  
manuals.  
*For allchanges,youmayvisitgenerallife.com.tr  
5
6
7
8
GeneralDetails
NameGENERAL LIFE 300S RF Wireless Room Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.05 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE 300S RF Wireless Room Thermostat User Manual