Home > GENERAL > GENERAL HT250 Smart Room Thermostat User Manual

GENERAL HT250 Smart Room Thermostat User Manual

TECHNICAL DATA  
ROOM THERMOSTAT PLACEMENT  
RECEIVER INSTALLATION  
ENGLISH  
Room Thermostat  
The room thermostat needs to be placed in the room which is used most  
frequently. For instance; the living room or lounge. Placing the room  
thermostat in a spot that has air circulation like the entrance of a room or the  
side of the window should be avoided. Also anywhere close to  
heating/cooling units such as a radiator, stove, and spots that get direct sun  
lights would not be suitable. The room thermostat needs to be located  
above the floor 150 cm in height. Few trials may be made to find the most  
convenientspot.  
First, shut down your heating/cooling unit and your heating/cooling unit's  
power sourcewithallelectricalcurrent(fuse, socket, etc.)  
As shown in the connection diagram, connect one end of the  
heating/cooling unit connection cable to the COM and the other to the NO  
input of thereceiver.  
Dimensions (H/L/W)  
Operating Current  
85mm / 125mm / 24mm  
3V DC (2 x AAA Alkaline Battery)  
SMART ROOM THERMOSTAT  
Temperature Measurement Accuracy 0.1oC  
Operating Sensitivity  
Operating Temperature Range  
Battery Life  
Operating Temperature  
Storage Temperature  
(-2.0oC) – (+2.0oC)  
(5oC) – (40oC)  
generallife.com.tr  
Connect the other ends of the cable -which you connected to the receiver-  
to the room thermostat connection terminal as shown in your  
heating/cooling unit's user manual.  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
You must first connect the receiver power cable to the receiver and then to  
thefuse to which the heating/cooling unit is connected.  
After completing the cable connection process, first, turn on yourfuse and  
then yourheating/cooling unit.  
HT250 SMART USER MANUAL  
min. 20 cm  
Receiver  
Dimensions (H/L/W)  
Operating Current  
Relay NO Switching Current  
90mm / 90mm / 25mm  
230V AC  
7A (240VAC – Resistive Load)  
10A (120VAC – Resistive Load)  
(-20oC) – (+60oC)  
WHAT IS A SMART ROOM THERMOSTAT?  
A smart room thermostat is a device that allows you to control your heating  
equipment via APPwiththe internetevenwhen youarenot athome.  
Finish the installation of the room thermostat to pair the receiver with the  
room thermostat.  
Storage Temperature  
ROOM THERMOSTAT  
1
RECEIVER WIRING DIAGRAM  
AC  
(230V)  
HOW DOES HT250 SMART WORK?  
COM  
NO  
HT250 SMART is a smart wireless room thermostat. You can control it with  
the mobile applicationafter you pair your room thermostatwith the receiver,  
andcompletetheinstallationofthesmartreceiver.  
2
WHAT ARE THE ADVANTAGES OF THE HT250 SMART?  
You can control your home's temperature via its mobile application, no  
matterwhereyouarein the world.  
3
4
You can easily create daily and weekly schedules via its mobile  
application.  
5
6
HEATING/COOLING UNIT  
You can place the room thermostat anywhere in your home, thanks to its  
use withbatteries.  
BATTERY PLACEMENT  
1
2
3
Battery Indicator  
Room Temperature  
Set Temperature  
Cooling Indicator  
Warning!  
Operations within the heating/cooling unit or the electrical installation must  
be carriedout byprofessionally qualified persons.  
It ensures that your living space stays at the desired temperature at any  
time. In this way, you can save up to 30% on your bills by preventing your  
heating unit from working unnecessarily.  
4
- If the Cooling Indicator is blinking, the cooling unit is working.  
- If the Cooling Indicator is steady, the cooling unit is not working.  
Heating Indicator  
- If the Heating Indicator is blinking, the heating unit is working.  
- If the Heating Indicator is steady, the heating unit is not working.  
ON/OFF and Temperature Setting Button  
PAIRING THE ROOM THERMOSTAT WITH THE RECEIVER  
RULES THAT NEED TO BE OBSERVED FOR SAFETY  
1-Be sure to read the user manual before using the device and its  
equipment.  
To pair the room thermostat with the receiver, press the “Manual  
Operation Button” and “Wi-Fi Pairing Button” together at the same time  
and seethereceiver's fastblinking red LED.  
5
6
2-Opening, disassembly, or use of plastic parts of the product and  
equipment other than theintended purpose areout of warranty.  
3-Please make sure that the sockets to which you connect your devices and  
equipment areattherecommended voltagevaluein the user manual.  
4-Keep away and protect your product and its equipment from all kinds of  
externalsubstances such asliquid, dust, heat, etc.  
Press thebutton for 3 seconds while yourdeviceis turned off.  
Pressthebutton until “  
” thepairing menu appears.  
Note: During active use of the room thermostat, the symbols indicated by 3,  
Turn yourroom thermostat's button while theLEDis fastblinking red.  
If the pairing is successful, the fast red flashing LED on the receiver will be  
steady.  
4 and 5 will not appear on thescreen.  
Press the screwdriver forward from the space at the bottom of the room  
thermostat, bend the tabs and separate the front cover. Insert 2 new AAA  
alkaline batteries in the battery housing with the correct battery direction.  
Replace both batteries at the same time. Align the front part of your room  
thermostat with the corresponding slot on the back, and then push gently  
until thethermostatsnaps into place.  
RECEIVER  
The receiverand room thermostathavebeen paired witheach other.  
5-Do not expose the device cables to any jamming and pressure. Take care  
to connect the devices' energy connection to the sockets you can always  
reach.  
1-Manual Operation Button:  
Deactivates the receiver and allows users  
SMART RECEIVER SETUP  
1
For smart receiver setup, download the application from App Store or  
Google Play or scan the QR code below with your smartphone. In this way,  
you will be able to download the mobile application from App Store or  
Google Play to your smartphone. (You may be required to have a QR code  
reader application depending on the brand and model of your phone, for  
this process.)  
to manually use the heating/cooling unit.  
2-Wi-Fi Pairing Button:  
Makes the receiver ready for smart  
6-Turn off the electrical power to prevent damage to your device and  
apparatus in caseof lightning and thunderstorms.  
2
Low Battery Warning: When the “  
” icon appears on the screen, it means  
3
“low battery warning”. It is recommended to replace the batteries when this  
warning appears.  
7-Turn off theelectricalpower when yourdeviceis not used for along time.  
8-Your devices and equipment should be used by paying attention to the  
matters stated in the user manual. In case of damage and malfunctions,  
arising from improper use (contact with liquid, falling to the ground, etc.)  
definitelyaskfor theinstaller's help.  
installation.  
3-Receiver LED Light  
4- Receiver Power Cable Input  
5- Heating/Cooling Unit Connection Cable  
Input  
Warning: When the product is not used for a long period (more than 15 days),  
remove the batteries. Otherwise, malfunctions that may occur would be out of  
warranty. Pleasethrowyour dead batteries into thewastebin for batteries.  
9-Call our service for maintenance and repair of HT250 SMART and its  
equipment. Maintenance and repair of the device and equipment should be  
carried out only by the technical service of ISIPARK A.S. and its authorized  
services, spare parts, and accessories specified by the company should be  
used.  
RECEIVER PLACEMENT  
The important things to note for the Receiver placement  
are avoiding physical contact between the receiver and  
the heating/cooling unit, and protecting it against  
materialssuch asliquid, dust, etc.  
4
5
RECEIVER LED DESCRIPTIONS  
Complete the user registration process by opening the mobile application  
thatyoudownloaded.  
Blinking Red  
The receiver did not get any signal from the  
HT250 SMARTand EQUIPMENT  
heating/cooling unit for 22 minutes or longer and  
the heating/ cooling unit has shut down.  
Waiting for a pairing signal from the room thermostat.  
The receiver and the room thermostat have been paired.  
Smart installation has not been completed.  
The receiver is in Bluetooth searching mode.  
Smart installation has been completed.  
The heating/cooling unit is not working.  
The heating/cooling unit is working.  
Open theBluetooth from yourmobile phone's settings.  
After you completed the user registration process, press the “+” button in  
the top-right corner of the main screen of the application, Press the  
receiver's Wi-Fipairing button for 5 seconds.  
The devices should be placed to minimize the damage to the received and  
transmittedsignals bypayingattentiontothefollowingpoints;  
HT250 SMART  
Room Thermostat  
Holder Alkaline  
Battery  
Receiver  
Dowels and  
Screws  
Fast Blinking Red  
Steady Red  
The devicesshould not be mounted on metalsurfaces.  
The devices should not be installed close to electrical cables and  
electronic equipment such ascomputers and televisionunits.  
The devices should not be installed near large metal structures or other  
building materials using fine metal meshes such as special glass or  
special concrete.  
The LEDon thereceiverwillstart to blink green.  
Blinking Green  
Steady Green  
Setup will begin with Bluetooth in the application. When the device is  
found, presstheAdd” button.  
Steady Turquoise  
3 Short Red Blinking  
Press the “+” button near the W Modem device and press the “Next”  
button aftermaking surethatyouentered thecorrectWi-Fiinformation.  
Wait until the setup process is completed. When you saw the green  
approvalsymbol on the W Modem, press the “Done” button in the top-right  
corner.  
Shut the heating/cooling unit down signal has  
reached the receiver.  
Distance between the room thermostat and the Receiver should not  
exceed 20metersor 2 floors.  
3 Short Green Blinking Operate the heating/cooling unit signal has  
reached the receiver.  
Blinking Red and Green The heating/cooling unit is working in manual mode.  
The receiver must be installed at least 50 cm away from the  
heating/cooling unit.  
2
1
3
4
GeneralDetails
NameGENERAL HT250 Smart Room Thermostat User Manual
MakeGENERAL
LanguageEnglish
FiletypePDF (Download)
File size2.2 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual

GENERAL HT250 Smart Room Thermostat User Manual
Get the free PDF manual for the GENERAL HT250 Smart Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL HT250 Smart Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Room thermostat placement is crucial for effective temperature control. It should be placed in the most frequently used room, avoiding areas with direct sunlight or near heating/cooling units. The room thermostat must be installed at a height of 150 cm above the floor. Receiver installation requires connecting the heating/cooling unit connection cable to the COM and NO inputs of the receiver. A smart room thermostat allows remote control of heating equipment via an app. The HT250 smart thermostat can help save up to 30% on heating bills by maintaining desired temperatures. Safety rules include ensuring qualified personnel handle electrical installations and avoiding exposure to liquids and dust. To pair the room thermostat with the receiver, specific buttons must be pressed simultaneously. Receiver placement should avoid physical contact with heating/cooling units and protect against liquids and dust. Receiver LED indicators provide information on the device's status, such as pairing and operational signals. The devices should not be installed near metal surfaces or electronic equipment to minimize signal interference.
  • Page 2: Heating/Cooling Unit Room thermostat temperature calibration Temperature sensors used in room thermostats are highly sensitive. The repair period of the product cannot exceed 20 working days. Your room thermostat has heating and cooling modes. You can reset your room thermostat to its default factory settings. The warranty period starts from the invoice date and is warranted against manufacturing defects for 2 years. The hysteresis positive factory setting of your room thermostat is 0.5°C. Your room thermostat measures sudden temperature changes with its open window detection feature. Malfunctions resulting from the use of devices contrary to the user manual are not covered by the warranty.