Re-calibrating the Thermostat  
This thermostat is factory set and need not re-calibrating under normal operation!  
To calibrate, follow the step below.  
Wiring Diagram  
Use the ‘Left/Right’ keys  
to scroll to the Power Icon  
.
230 VAC  
MAINS SUPPLY  
RCD  
Press and hold to turn the display ‘OFF’ .  
Floor  
Sensor  
Not used.  
Press and hold the and ‘Down’ keys together for 10 seconds.  
L
N
The current temperature will appear on the display.  
LOAD  
-
RT1  
N
N
L
Use the ‘Up/Down’ keys  
to configure the new temperature value.  
Press the key to confirm the change and the display will go blank .  
Press the key once to turn the thermostat ‘ON’.  
Error Codes  
The ProDigital™ will display an error code if there is a fault with the temperature  
FLOOR PROBE  
MATTING OR WIRE - 16 AMP MAX  
sensor, these error codes are explained below.  
E0 = The internal sensor has developed a fault.  
E1 = The remote FLOOR probe has not been connected.  
The remote FLOOR probe has not been wired correctly.  
The remote FLOOR probe is faulty.  
This product must only be installed by a qualified electrician and  
comply with local installation regulations.  
26  
27  
GeneralDetails
Namefastwarm HM-01-16A Digital Programmable Thermostat Instruction Manual
Makefastwarm
LanguageEnglish
FiletypePDF (Download)
File size0.22 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
fastwarm 16AMP Touchscreen Thermostat Instruction Manual
fastwarm 16AMP Touchscreen Thermostat Instruction Manual

fastwarm HM-01-16A Digital Programmable Thermostat Instruction Manual