FEATURES  
On Appearance  
Shell Material: PC +ABS ( flame retardant)  
C
BHT-2000 Series Zigbee Thermostat  
Touch the icon to set minute, hour and weekday (1 = Monday,  
2 = Tuesday etc.) by using the arrows. Press  
User Guide  
once more to  
Wire Terminals: Wire 2 x 1.5 mm2 or 1 x 2.5 mm2  
20  
confirm and exit.  
5. Locking your Thermostat  
Press and hold the  
3.Fashion design blends in with any decor.  
4.Touch Screen display with backlight is easy to  
read ,even in the dark.  
for 5 seconds to lock/unlock your thermostat  
lock or half lock.  
BEFORE WIRING AND INSTALLING...  
P
S
exist.  
Method one  
6.Easy UI interface could be used even by child.  
3. Installer must be a trained, experienced service technician.  
are as follows:  
Modbus /WIFI /Zigbee ect.,  
2. 0.5°C Accuracy keeps temperature within the level you set.  
3. Data memory when power is off.  
Touch  
to change between manual mode and programme  
M
CAUTION  
In programme mode, touch and hold the icon  
For Water Heating/Boiler/Electric Heating  
4. 5+1+1 four periods programmable maximize comfort and economy.  
5. Create thermostat group to Centralized control  
Electrical Shock or Equipment Damage Hazard. Can shock  
individuals or short equipment circuitry.  
Thermostat Colors:  
002FB: full black  
002FW: full white  
6.  
HOME SCREEN QUICK REFERENCE  
Press the icon  
002BW: black and white  
002WB: white and black  
(1st period).Press  
Press the icon  
temp. (2nd period).Repeat this process for periods 3 4 and 5 6.  
again and use  
and  
arrows to set the temp.  
WIRING  
DIMENSION  
GA  
Welcome  
Thank you for your purchase.  
Your new thermostat will provide uniform and comfortable  
temperature control throughout every room in your property. We  
bring together technology,  
AC95~240V  
NTC  
Press the icon  
N
L
Saturday  
IP20  
M
Close  
Open  
5
6
GB  
Repeat the above process to set the period and temp. and Sunday  
schedule.  
1
3
4
2
A (RED)  
B (WHITE)  
AC95~240V  
materials to provide you with a safe, reliable product combined with  
sleek, contemporary design.  
N
L
NTC  
Press  
once more to confirm and exit.  
IP20  
LOAD  
Modbus  
programming manual for comprehensive  
thermostat. Please also  
ensure a suitably qualified person installs your thermostat and  
N1  
L1  
5
6
1
3
4
GC  
2
A (RED)  
B (WHITE)  
WEEKDAY(MONDAY-FRIDAY) WEEKDAY(MONDAY-FRIDAY) WEEKDAY(MONDAY-FRIDAY)  
AC95~240V  
Time display  
(1 2 3 4 5 shows on scteen)  
(6 shows on scteen)  
(7shows on scteen)  
N
L
NTC  
IP20  
Dry Contact  
Modbus  
TIME  
6:00  
TEMPERATURE  
TIME  
6:00  
TEMPERATURE  
TIME  
6:00  
TEMPERATURE  
Note:  
GA  
5
6
In the box you will find  
Period 1  
Period 2  
Period 3  
Period 4  
20  
21  
22  
23  
24  
23  
22  
21  
19  
20  
20  
21  
1
3
4
2
2pc  
Screws  
Floor Sensor (2.5m) 1pc  
1pc  
1pc  
1pc  
A (RED)  
B (WHITE)  
Thermostat  
User Guide  
11:30  
13:30  
17:30  
12:00  
14:30  
17:30  
12:30  
14:30  
18:30  
GC is for water/gas boiler;  
Modbus  
QC Passed  
INSTALLATION  
OPERATION  
During Power On  
ABOUT YOUR THERMOSTATS  
The BHT-2000 series range has been developed to control electric  
A separate schedule may be set for weekdays (Mon – Fri) and for  
weekends (Sat or Sun).  
Press  
to turn the thermostat on/off.  
1. Power On/off:  
2. Manual & Programmable  
Step 1. Keep power off. See Fig 1.  
TECHNICAL DATA  
Power Supply: 95 ~ 240 VAC, 50 ~ 60HZ  
Current Load:3A(  
Method Two  
Touch  
(mode) to change between manual mode and programme  
M
second page "Programming your thermostat"  
MODEL DEFINITION  
GC: Water/Gas Boiler, 3A  
Sensor: NTC  
Accuracy: ±0.5℃ or ±1℉  
Set Temp. Range: 5 -35℃  
7. Checking the Temperature of Floor Sensor  
Press and hold the  
floor sensor.  
In programmable mode, the perio  
arrow for 5 seconds to display the temp. of  
L: Backlight  
P: Weekly Programmable  
W: Wifi  
Dispaly Temp. Range: 5 ~ 99℃  
Ambient Temp.: 0 ~ 45 ℃  
Ambient Humidity: 5 ~ 95 % RH (Non Condensing)  
Storage Temp.: -5 ~ 45 ℃  
could not be  
adjusted. If the user want to change, please go to manual mode  
or programmable mode.  
Step 3. Connect power supply, load into the appropriate terminals.  
(see “Wiring your thermostat” for details and Fig 3).  
Z: Zigbee  
S2: Both internal sensor and floor external sensor  
For example: BHT-2000 GC  
In the mode of manual, press  
to set the desired temperature.  
Timing Error: < 1%  
the box. See Fig 4.  
GeneralDetails
Nameexpert4house BHT-2000 Series Zigbee Thermostat User Guide
MakeEXPERT4HOUSE
LanguageEnglish
FiletypePDF (Download)
File size3.16 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
expert4house BHT-006 Series Thermostat Instruction Manual
expert4house BHT-006 Series Thermostat Instruction Manual
expert4house BHT-003 Series Zigbee Thermostat User Guide
expert4house BHT-003 Series Zigbee Thermostat User Guide
Expert4house BHT-9000 Smart Knob Thermostat User Guide
Expert4house BHT-9000 Smart Knob Thermostat User Guide
expert4house BHT-12 Smart Thermostat User Manual
expert4house BHT-12 Smart Thermostat User Manual
expert4house BHT-18 AI Knob Thermostat User Guide
expert4house BHT-18 AI Knob Thermostat User Guide
expert4house BHT-8000 Heating Thermostat User Guide
expert4house BHT-8000 Heating Thermostat User Guide
Expert4house BAC-1000ALNE Room Thermostat User Guide
Expert4house BAC-1000ALNE Room Thermostat User Guide
EXPERT4HOUSE BAC-9000 Smart Knob Thermostat User Guide
EXPERT4HOUSE BAC-9000 Smart Knob Thermostat User Guide

expert4house BHT-2000 Series Zigbee Thermostat User Guide