BUDDERFLY BTS-U1 Thermostat User Manual
| General | Details |
|---|---|
| Name | BUDDERFLY BTS-U1 Thermostat User Manual |
| Make | BUDDERFLY |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.35 MB |

BUDDERFLY BTS-U2 Thermostat User Manual

BUDDERFLY BTS-U1 Thermostat User Manual Overview
Summary of Contents
- Page 1: Budderfly Thermostat – BTS-U1 User Manual
- Page 2: Introduction Systems compatibility Specifications Terminal description Wiring diagrams Getting started Existing thermostat replacement LCD display functions Main screen operations Operation of feature settings
- Page 3: Reset factory settings Regulatory
- Page 4: Introduction Budderfly thermostat regulates temperature in heating or cooling systems by measuring the current temperature and comparing it to a set temperature, called the setpoint. The thermostat has internal temperature and humidity sensors and can connect to an external temperature sensor. When the current temperature deviates from the setpoint, the thermostat sends a signal to adjust the heating or cooling system. It is powered by 24 VAC, can control 2 cooling and 3 heating stages, and has Wi-Fi connectivity. The thermostat can be locked with a pin and allows for remote temperature control through Budderfly apps. It can be programmed with different setpoints for different times of the day and for 7 days. Manual override options are available for immediate temperature adjustments. Systems Compatibility The Budderfly Thermostat BTS-U1 operates with low-voltage heating and cooling systems only. It supports multiple system types, including gas heating, oil heating, electric heating, traditional AC, heat pumps, dual fuel systems, boilers, floor heating systems, and fan coil units.
- Page 5: Specifications Dimensions: H 96 mm x W 86 mm x D 31 mm Display Resolution: 480 x 320 Display Size: 73.4 mm Height 489 mm Width WI-FI: 802.11 b/g/n (2.4G) TOUCH Capacitive Input Voltage: 24VAC, 50/60 Hz Relay Rating: 24VAC@ 1Amp maximum per relay Operating Temperature: 32 F to 150 F Operating: RH 0% -90% (non-condensing) Storage Temperature: 32 F to 150 F Temperature Sensors: Thermistor 10K NTC type 2
- Page 6: BTS-U1 user manual Wiring diagrams for different system types configurations Wire colors are for reference only. Not every installation will have wires of the same color. Contact a licensed electrician or a professional HVAC installer if unsure about installation. Maximum wire length allowed varies by wire gauge. Acceptable maximum length for 18 #AWG is 128ft or 38m. Acceptable maximum length for 20 #AWG is 80ft or 24m. Acceptable maximum length for 22 #AWG is 50ft or 15m.
- Page 7: Page 7
- Page 8: Getting started Existing thermostat replacement Step 1. Power off HVAC equipment Before disconnecting the existing thermostat, disconnect the power to the heating and air conditioning equipment. Step 2. Remove existing thermostat Disconnect the wires to the existing thermostat and remove it from the wall. Step 3. Install the BTS-U1 The ideal location for the thermostat is approximately 5 ft (1.5 m) above floor level in the main living area. Warning: Do not install the thermostat close to sources of heat, near supply heating/cooling sources, in direct sunlight, or in areas that could restrict air flow. To install the thermostat, gently separate the backplate from the thermostat and place it on the wall. Step 4. Connect the wiring You need to use low-voltage cable to connect the thermostat to the HVAC equipment.
- Page 9: BTS-U1 user manual Connect the wires as shown in the wiring diagrams. Attach the BTS-U1 to the backplate. Ensure that the pins on the thermostat align with the terminal block on the backplate. After you've completed the wiring, you can apply power to the heating and air conditioning equipment. The EMS Si receives power from the equipment and will automatically power on. Entering the Installer setup menu involves pressing the icon on the main screen and selecting 'Installation Settings.' Input the password 1234 to continue with the installation settings. The LCD display functions include a Wi-Fi indicator, history data, and system mode options. Humidity values are indicated, with a pointer in the red area if the value is less than 30%.
- Page 10: BTS-U1 - User Manual If humidity value is between 30% and 60%, the pointer will be in the Green area. If humidity value is more than 60%, the pointer will be in the Gray area. Power ON/OFF. Holiday: Displayed when thermostat is in holiday mode. Schedule: Programmable Operation. The Temperature Hold function allows you to manually override the current operating program and set a different temperature for a desired period. The MC6 will maintain this temperature for the duration of the holiday and will then automatically return to the program mode on your return. Click the “Fan” on the Main Display, and change the Fan mode to Auto or High.
- Page 11: Schedule Select the “Schedule” on the Main Display, and enter the “Edit” interface. On the Edit Page, from Monday to Sunday can be selected to edit. Click “Monday” and enter Monday’s setting interface. There are four time periods that can be selected: Morning/Day/Evening/Night. Click the First Column of “Time” to set desired “Hour” and the Second Column to set desired Minute. For example, the setting time is 04:00 am. For example, the setting temperature is 80.6 ℉. Four time periods: 04:00 am-10:40 am, 10:40 am-8:30 pm, 8:30 pm-12:00 pm. To set the clock, select the “gear” icon and enter Feature Settings. Select the “Clock Setting” to enter Setting Interface.
- Page 12: User manual for BTS-U1 includes instructions for setting date and time, backlight settings, standby screen, screen lock, temperature format, and temperature limit. Select the column of Year/Month/Day to set values using arrow icons. Choose dimming preference for backlight settings between automatic and manual. Adjust standby screen time with options of 3Min, 10Min, Just Night, or Never. Enable or disable screen lock using the slider. Select temperature format between °C and °F. Adjust minimum temperature limit between 41°F and -93.2°F. Use the back icon to save settings and return to the main display. Access feature settings by clicking the gear icon. Follow the instructions for each setting to customize the device.
- Page 13: BTS-U1 user manual Maximum temperature ranges from 42.8°F to 95°F. Switch differential allows you to increase the thermostat's switching differential. The system defaults to 32.9°F for heating settings. Output delay can be set from 0 to 15 minutes to prevent rapid switching. Daylight saving time settings can be accessed through feature settings. Three options for daylight saving time: European Union, US & Canada, Australia & New Zealand. System information displays the version number: Pro-3.43s. Resetting factory settings will erase current settings and restore defaults.
- Page 14: BTS-U1 user manual This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: it may not cause harmful interference and must accept any interference received. The device has been tested and found to comply with Class B digital device limits. These limits provide reasonable protection against harmful interference in residential installations. The device generates, uses, and can radiate radio frequency energy. If harmful interference occurs, users are encouraged to try correcting it by reorienting the receiving antenna, increasing separation between equipment and receiver, or consulting a technician. The Grantee is not responsible for changes or modifications not approved by the responsible party. This device complies with FCC radiation exposure limits for uncontrolled environments. It should be installed and operated with a minimum distance of 20cm between the radiator and the body.



























