6. Setting functions and options
4. Setting the system mode
Installing your thermostat
During power off, press and hold M
at the same
Press M to change the system mode HEATING,
COOLING and VENTILATION. In the mode of
VENTILATION, the valve is off but the fan runs.
This product is suitable for standard 86mm wall
box or european 60mm round box.
time for 5 sec. to system functions. Then press M
to change the different items.
Press
or
to set the relative values.
All the settings will confirm automatically when
power is on.
5.Setting the Clock
Press and hold Mto set the clock.
Press
Press M to set minutes of the time;
Press to set hours of the time;
to adjust the relative value.
N
o.
Function
Settings & Options
°C
Default
T
em
p.
-9
t
o
9
-2
1
Calibration
(Fig 1)
M
00: When room temp. re
setpoint, the fan will n off
01: When room temp. re
setpoint, the fan will
a
c
h
e
s the
s the
M
Press to set week of the time;
1. Connect the wire of power and other equipment into
the terminals.
t
u
r
.
After that,all will be confirmed automatically.
00
ache
2
Fan Control
t
ur
n to low spee
cked except
cke
d.
00: All the buttons are
OWE
lo
Wiring your thermostat
3
4
L
ock
P
R
00
01
01: All the buttons are
lo
d
00: Cooling only
He
a
ting/Cooling
01: Heating/Cooling 02:Heating only
5
6
7
Min. Set Tem
p
.
5
5
-
15°C
35°C
5
Max. Set Tem
Time Display
p
.
-
30
01
(Fig 2)
00: 12hours
00: Display both set temp. and
room tem
01: Display set temp. only
1-5
01: 24hours
2. Fix the wall plate into the wall box by a screwdriver.
8
Display
m
ode
00
p
.
9
Deadzone Temp.
°C
0x00-0xFFFF
9600
5: 56000 6: 57600 7: 115200
1
1
A
Modbus IP address
1
:
2
:
14400 3: 19200 4:38400
Baud Rate Setting
Modbus version
B
C
1
(Fig 4)
4. Finished.
402
(Fig 3)
3. Connect the LCD board into the wall plate.
WARNING: Please arrange the professional technician
to install this product according to installation drawing and
instruction.
Note:1.Please cut off the electricity when you
want to pull out the external sensor.
2. When the external temperature sensor
is not connected, the thermostat uses
the built-in temperature sensor to detect
the room temperature; when the external
temperature sensor is connected, the
thermostat uses the external temperature
sensor to detect the room temperature,
and does not use the built-in temperature
sensor;
SIMPLE EXCEPTION HANDLING
No.
1
Phenomenons
Handling
RISK OF ELECTRICAL SHOCK. Disconnect power supply
before making electrical connection. Contact with components
carrying hazardous voltage can cause electrical shock and may
result in severe personal injury or death.instruction.
Power is on but without display.
* Check if the terminals between LCD panel and
Power Unit Box is loosen.
2
3
Without output but display works.
* Use a new LCD panel or new Power Unit Box to
replace the old one.
Room Temp. Is a little different from * Do temperature calibration in item 1 of high
the actual. senior options
| General | Details |
|---|---|
| Name | Expert4house BAC-1000ALNE Room Thermostat User Guide |
| Make | EXPERT4HOUSE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.56 MB |

expert4house BHT-006 Series Thermostat Instruction Manual

expert4house BHT-003 Series Zigbee Thermostat User Guide

Expert4house BHT-9000 Smart Knob Thermostat User Guide

expert4house BHT-12 Smart Thermostat User Manual

expert4house BHT-2000 Series Zigbee Thermostat User Guide

expert4house BHT-18 AI Knob Thermostat User Guide

expert4house BHT-8000 Heating Thermostat User Guide

EXPERT4HOUSE BAC-9000 Smart Knob Thermostat User Guide