8
Green normally open mode (COM NO). It is the most commonly used operation mode.  
While the device operation indicator is active the output cables are shorted.  
Red normally closed mode (COM NC). While the device operation indicator is active the  
output cables are opened.  
Caution! Normally open mode (COM NO) is preset by default.  
8. FIRST START  
After being connected to the power socket the receiver signals the transmitter operating mode.  
A flash of the green LED normally open mode (COM NO), a flash of red LED normally  
closed mode (COM NC).  
Each and every change to thermostat status (switching the heating on/off) is executed by the  
receiver instantly, whereas the signalization confirming the reception of the radio signal from  
the transmitter is repeated every 15 minutes.  
8.1. Strength of radio signal  
Information on the strength of the radio signal is communicated together with the signalization  
of the reception signal from the transmitter. The reception of the radio signal is signaled in  
greed. Three flashes of the LED stand for exceptionally good reception, two flashes stand for  
good reception, and one flash for sufficient reception.  
8.2. Lack of radio communication  
If the communication between the thermostat and the receiver is interrupted (e.g. discharged  
batteries) and such status lasts for 2 minutes (no response from the receiver) then the  
receiver switches into the frost protection mode. The heating device will be switched on for 20  
minutes every 3 hours so that the rooms are not cooled down. At the time of re-establishing  
communication (replacement of batteries), the receiver turns the system off and automatically  
resumes the operation.  
Lack of radio communication is signaled by a fast flashing green LED.  
8.3. Continuous operation of the heating device (MAN)  
In the case of system failure, it is possible to switch the system on manually. Move the switch  
on the RX receiver to the MAN position. Such status is signaled by fast flashing red LED (in the  
heating mode) or blue LED (in the cooling mode).  
8.4. Receiver signaling table  
Function  
Signal  
Pairing  
Blue  
Reception of radio signal  
Green  
Lack of signal  
Green flashing  
Red  
Red flashing  
Blue  
The heating device switched on  
Manual mode in heating operation  
The air-conditioning device switched on  
Manual mode in air-conditioning operation  
Blue flashing  
9. Sample Connection Diagrams  
The following diagrams are simplified and do not cover all elements necessary for the correct  
installation.  
In arrangement with a 230 V 50 Hz device  
1. Electrical connection block  
2. Output cable using COM - NO contact (normally open)  
GeneralDetails
NameEUROSTER 2006TXRX Wireless Programmable Thermostat Installation Guide
MakeEUROSTER
LanguageEnglish
FiletypePDF (Download)
File size0.28 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
EUROSTER 4040 Smart Programmable Thermostat User Manual
EUROSTER 4040 Smart Programmable Thermostat User Manual
EUROSTER 2026TXRX Air Conditioning Thermostat Instruction Manual
EUROSTER 2026TXRX Air Conditioning Thermostat Instruction Manual

EUROSTER 2006TXRX Wireless Programmable Thermostat Installation Guide