Troubleshooting  
When a fault occurs, the EB-Therm 500  
turns the heating off. The display then  
shows an error code.  
E1 Short circuit room sensor.  
E2 Interruption room sensor.  
E3 Short circuit floor sensor.  
E4  
Interruption floor sensor.  
E5 Internal sensor fault.  
E6 Internal over temperature  
Please note that the floor heating system is  
a high voltage system and any faults must  
therefore be rectified by an authorised  
electrician.  
Test values for floor sensors  
For control measurement of the floor sen-  
sor, the following values for Ebeco standard  
sensor NTC 10 kΩ apply.  
Temperature  
10 °C  
Resistance  
18.0kΩ  
14.7 kΩ  
12.1 kΩ  
10.0kΩ  
8.3 kΩ  
15 °C  
20°C  
25°C  
30°C  
32  