Danfoss CET B-RF ATC Cylinder Thermostat Installation Guide
Installation Instructions
ATC Cylinder Thermostat
SPECIFICATION
:
This product complies with the following EC Directives
Temperature Range : 30 - 90°C
Electro-Magnetic Compatibility Directive.
(EMC) (89\336\EEC), (92\31\EEC)
Low Voltage Directive.
Construction : BS/EN 60730
Max. ambient temp. : 45°C
(LVD) (73\23\EEC), (93\68\EEC)
Pressure Directive (PD) 97\23\EC
IP Rating
: IP40
: 6(2.5)A
Certification Mark
Switch Rating
Switch Type
Switching Differential : 6-10
: SPDT (type 1B)
Switch Configuration : 1-3 Make on temp. rise
1-2 Break on temp. rise
WIRING DETAIL
Voltage Rating
: 220/240 VAC, 50/60 Hz
2
/
3
PLACING OF THERMOSTAT
Position thermostat 1/3 up from base of cylinder.
ATC
Fit to cylinder using spring cord supplied.
1
/
E
3
1
2
RECOMMENDED SETTING
55-60°C
3
(N.O.)
(COM)
(N.C.)
What is a cylinder thermostat? ... an explanation for householders
A cylinder thermostat switches on and off the heat supply from the boiler to the hot-water cylinder.
It works by sensing the temperature of the water inside the cylinder, switching on the water
heating when the temperature falls below the thermostat setting, and switching it off once this set
temperature has been reached.
Turning a cylinder thermostat to a higher setting will not make the water heat up any faster. How
quickly the water heats up depends on the design of the heating system,for example,the size of boiler
and the heat exchanger inside the cylinder.
This text has been edited and approved by
the Plain English Campaign, who has issued
a Crystal Mark to be displayed with it.
The water heating will not work if a time switch or programmer has switched it off. And the cylinder
thermostat will not always switch the boiler off, because the boiler sometimes needs to heat the
radiators.
Cylinder thermostats are usually fitted between one quarter and one third of the way up the cylinder.
The cylinder thermostat will have a temperature scale marked on it, and it should be set at between
60°C and 65°C, then left to do its job. This temperature is high enough to kill off harmful bacteria in
the water, but raising the temperature of the stored hot water any higher will result in wasted energy
and increase the risk of scalding.
If you have a boiler control thermostat,it should always be set to a higher temperature than that of the
cylinder thermostat. In most boilers, a single boiler thermostat controls the temperature of water sent
to both the cylinder and radiators, although in some there are two separate boiler thermostats.
DanfossRandallcanacceptnoresponsibilityforpossibleerrorsincatalogues,brochuresandotherprintedmaterial.DanfossRandall
reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations
can be made without subsequent changes being necessary in specifications already agreed.
Danfoss Randall Ltd
Ampthill Road
Bedford, MK42 9ER
Tel: (01234) 364621 Fax: (01234) 219705
Email: danfossrandall@danfoss.com
Part No. 9611v05 07/07
| General | Details |
|---|---|
| Name | Danfoss CET B-RF ATC Cylinder Thermostat Installation Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.06 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide