BUDDERFLY BTS-U2 Thermostat User Manual
BTS-U2 – User Manual
Maximum Temperature to 42.8℉-95℉.
Click the back icon twice to save and return to main screen.
7.
8.
Switch Diff
This function allows you to increase the switching differential of the thermostat. The
system defaults to 32.9℉, meaning that when the temperature is set to 68℉, the
thermostat will start heating at 67.1℉ and stop at 68℉. If the default value is 33.8℉,
start heating at 66.2℉, stop at 68℉.
Output Delay
To prevent rapid switching, an output delay can be entered and can be set from 0-15
minutes. (The default is 00, means no delay)
9.
Daylight Saving Time
Click the gear icon and enter Feature Settings.
Select “DST” then “Auto DST” to enter setting interface.
There are three options:
European Union / US & Canada/Australia & New Zealand
Select the back icon to save and return to main screen.
10.
11.
System Information
Click the gear icon to enter feature settings.
Select “System Information” to enter interface,
It will show shows Version Number : Pro-3.43s.
Select the back icon to Exit.
Reset Factory Settings
Click gear icon then “Reset Factory Settings” and enter setting interface.
Warning: Reset will make you lose the current Settings and return to
the factory Settings.
Page - 14 -
Document Version - 1