aube Electronic Thermostat TH131 Owner’s Manual
TH131
Power
Terminals 1 & 5
Load
Terminals 2 & 4 (see note 1)
Terminal 3 (see note 2)
Pilot Wire
Floor sensor
Terminals 6 & 7; no polarity (see note 3)
NOTE 1 If a contactor is used between the thermostat and the load, install a
snubber at the contactor’s coil terminal to ensure the proper operation
of the thermostat.
NOTE 2 Optional (see page 10).
NOTE 3 For the proper operation of the thermostat, the floor sensor must be
centered between two heater wires having a maximum temperature
of 80°C (176°F). The floor sensor wire must not cross any heater wire
or be placed close to it.
NOTE 4 Ensure that the wires are tightly secured to the terminals. Apply a
minimum torque of 0.5 Nm (4.4 Lb/in) when tightening the screws.
NOTE 5 The terminals are designed to handle a cross-section of wire
2
measuring 0.33 to 3.1 mm .