Home > American Standard > American Standard ACONT103 NP Non Programmable Heat Pump Thermostat Instruction Manual
American Standard ACONT103 NP Non Programmable Heat Pump Thermostat Instruction Manual
American Standard 103 Non-Programmable
4.4 Wiring Diagrams
Heat Pump with TAM Series 24V
Thermostat
Indoor Unit
Outdoor Unit
R
O/B
Y
R
O
R
O
Y1
G
E
G
W1
X2
B
C
L
B
Y0
Y2
W2
Y/Y1
NOTES:
W2
1) Wire third party condensate overflow
switches between Y of the thermostat
and Y1 of the airflow control board
2) X2 is required to energize aux heat
during defrost
W3
BK
Heat Pump with S9V2 Furnace
Thermostat
Indoor Unit
Outdoor Unit
R
O/B
Y
R
O
R
O
Y1
Y/Y1
G
E
G
W1
X2
B
C
L
B
Y2
W2
W2
NOTES:
1) Wire third party condensate overflow
switches between Y of the thermostat
and Y1 of the airflow control board
2) X2 is required to energize aux heat
during defrost
W3
BK
Pub. No. 11-HD24D1-1C-EN 09/2020 Part No. 37-7792003