Home > Tio > TX1000 Thermostat Instruction Manual

TX1000 Thermostat Instruction Manual

PROGRAM SETTING  
CONFIGURATION MENU  
LCD DISPLAY REFERENCE  
Turn off the stat  
enter configuration menu. During this menu,  
short press to change parameters. Press  
Press  
button for 5 seconds to  
When power is on, press  
for 5 seconds to enter  
to change the different  
programmable mode. Press  
to  
items. Press  
to set the relative values.  
The order is Minute → Hour → Temperature → Minute  
timing-on → Hour timing-on→ Minute timing-off→ Hour  
timing-off→ Temperature adjusting.  
confirm the setting.  
APPLICATION  
(“Mon-Fri”,”Sat”,”Sun”, is “5+1+1” programmable  
mode, every mode has two times zones and a time  
temperature setting)  
This thermostat range has been developed to control  
electric underfloor or water heating or water/gas boiler  
system. These units are designed for use in commercial,  
industrial, civil, and domestic properties.  
FEATURES  
QUICK FUNCTIONS  
Press this button to power on/off your thermostat.  
Time setting: Press button to set min/hour/day.  
Manual/program setting.  
•
•
•
•
•
•
•
•
Simple installation  
Acrylic face plate  
Large, backlit display  
INSTALLATION  
Manual mode: Press  
to select manual mode.  
Sleek, contemporary design  
Elegant chrome frame  
When you are on manual mode will show in bottom  
left corner. Press  
to select desired temperature.  
to select program mode.  
Feather touch control panel  
5+1+1 six period per day programming  
Simple, one-touch temperature control over-  
ride. Pre-set temperatures maintained within  
+/- 1°C Internal and external sensors allow  
control of  
Program mode: Press  
When you are on program mode will show in bottom  
left corner. Press for 5 seconds to activate program  
set mode. Press to set the desired (5+1+1) six periods  
time and temp. When you have set your time and temp  
period press  
Temporary mode: During program mode. If you need to  
change the temp. The icons will appear. The pre-  
program setting will return in the next period.  
to save and return to home screen.  
•
•
both air and/or floor temperatures  
Suitable for installation in a standard single back  
box.  
DIMENSIONS  
•
WIFI/ZIGBEE/MODBUS communication optional  
Child Lock set: Press and hold the  
button for 5  
seconds to lock/unlock your thermostat.  
Factory re-set: Press  
button for 5 seconds to enter  
TECHNICAL INFORMATION  
program mode. Press and hold  
for 5 seconds.  
When the ‘def’ flashes on the screen your thermostat  
has been re-set to factory settings.  
Sensor:NTC  
Accuracy:±1℃  
WIRING DIAGRAM  
Power Consumption:< 1.5W  
Timing Error:<1%  
Power Supply:95 ~ 240VAC, 50 ~60Hz  
Current Load:5A(water heating, water/gas boiler),  
16A(electric heating)  
Shell material:PC+ABS (flame retardant) Dimension:  
86x86x13.3mm  
Ambient Temp.:0-45℃,5-95%RH  
(Non-condensing)  
Storage Temp.:-5-55℃  
Installation Hole distance: 60mm  
GeneralDetails
NameTX1000 Thermostat Instruction Manual
MakeTio
LanguageEnglish
FiletypePDF (Download)
File size0.29 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)