Home > SEELEY > SEELEY Ducted Gas Heater with MagiQtouch Controller or Manual Thermostat Owner’s Manual
SEELEY Ducted Gas Heater with MagiQtouch Controller or Manual Thermostat Owner’s Manual
Advice for the Home Owner
Gas Rate & Fan Speed Adjustment.
Adjusting the Maximum Gas Rate
For TQM, TQS & TQA. (except TQS3)
If your home is not reaching the temperature you set on your MagIQtouch Controller, please check the
maximum gas rate setting and increase it, if not already set to the maximum 100%.
Increasing the maximum gas rate setting to 100% will increase the heat output to the heater’s
maximum design output.
The maximum gas rate setting can be adjusted by selecting:
SETTINGS > HEATER > GAS RATE on your MagIQtouch Controller.
You can select between...............25%, 50%, 75% and 100%.
A reduced maximum gas rate setting should only be used when the heater output needs to be reduced,
for example when the outside temperature increases, or some outlets/vents have been closed.
Maximum fan speed
Maximum gas rate setting %
automatically reduces to
10
7
4
100%
75%
50%
25%
Note:
Reducing the maximum gas rate setting also automatically
reduces the maximum room fan speed as shown in the chart:
2
Adjusting the Room Fan Speed
ONLY for systems where a single MagIQtouch Controller is installed
For TQ4, TQM, TQS & TQA. (except TQS3)
If your home is not reaching the temperature you set on your MagIQtouch Controller, please check the
room fan speed setting and increase it, if not already set to the maximum 10.
This will increase the heat output and increase the distribution of heated air through your home.
The maximum room fan speed can be adjusted by selecting:
SETTINGS > HEATER > SET FAN SPEED on your MagIQtouch Controller.
You can select between...............1, 2, 3, 4, 5, 6, 7, 8, 9 and 10.
Maximum gas rate
automatically adjusts to....%
Maximum fan speed setting
Reducing the maximum room fan speed will:
Reduce air flow noise,
Reduce heat output and,
10
100%
75%
9
8
7
6
5
4
3
2
1
Reduce the distribution of heated air around your home.
Note: For TQM, TQS & TQA. (except TQS3)
Reducing the room fan speed setting also automatically
reduces the maximum gas rate setting as shown in the chart:
50%
25%
Note:
The room fan speed is not user-adjustable in systems with
multiple MagIQtouch Controllers or Air Temperature Sensors.
3
| General | Details |
|---|---|
| Name | SEELEY Ducted Gas Heater with MagiQtouch Controller or Manual Thermostat Owner’s Manual |
| Make | SEELEY |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.49 MB |