Thermostat Program Mode
There are 3 period modes: 5 (weekdays) + 2 (weekend days), 6 + 1 and 7 days. Choose period of your
choice by long pressing
choose: hour, minute time period and press
Once finished setting after 10 seconds thermostat will automatically save & exit.
for 3-5 secs. Enter into prgrammable mode. Then short press
and to increase and decrease values.
Wake Up
Outdoor
Back Home
Out Door
Back Home
Sleep
20°C
15°C
15°C
15°C
15°C
15°C
6:00
8:00
11:30
13:30
17:00
22:00
The optimum comfort temperature is 18°C - 22°C
Advanced Options
With the thermostat turned off, long press
From A1 to AD short press to toggle through the options. Adjust data by using the up
to go to next option. After about 5 secs. the thermostat
for 3-5 secs. to access advanced settings.
and down
arrows. Short press
will save & exit on its own.
NO
Settings Options
Data Setting Function
Factory Default
Measure temperature
calibration
0.5°C Accuracy
Calibration
Change value range -9°C to + 9°C
A1
Temperature control return
difference setting
Change value range 0.5°C to + 2.5°C
Change value range 1°C to + 9°C
1
2
°C
°C
A2
A3
External sensors limit
temperature control return
difference
N1: Built-in sensor (high temperature protection close).
N2: External sensor (high temperature protection close).
N3: Built-in sensor control temperature, external sensor limit
temperature (external sensor detect the temperature is higher
than highest temperature of external sensor, thermostat will
disconnect relay, turn off load).
Options of sensor control
N1
A4
Children lock setting
0: Half Lock
1: Full Lock
0
A5
A6
Limit value of high
temperature for external
sensor
1.) 35°C - 75°C
2.) Under 35°C, screen display
protection was cancelled.
, high temperature
, low temperature
45°C
Limit value of low
temperature for external
sensor (anti-freeze
protection)
1.) 1°C - 10°C
2.) Exceed 10°C, screen display
protection was cancelled.
5
5
°C
°C
A7
Setting temperature lowest
limit
1
°C - 10°C
A8
A9
Setting temperature highest
limit
20°C - 70°C
35°C
0: Close descaling function.
1: Open descaling function ( valve is continuously closed
over 100 hours, it will be opened for 3 minutes automatically.
0: Close descaling
function
Descaling function
AA
Ab
AC
0: Power with memory function.
Power with memory function 1: Shutdown power after power off
2: Shutdown power after power on
0: Power with
memory function
0: 5 + 2 ( 5 weekdays + 2 weeekend days) etc.
1: 6 + 1
2: 7
Weekly programming
selection
0: 5 + 2
Displaying A0, press
show all icons
key until whole LCD
OK
Ad Restore to factory defaults