PRO T755 Universal Thermostat Installation Guide
Installation Manual
Installation Tips
Wall Locations
The thermostat should be installed approximately 4 to 5 feet above the
floor. Select an area with average temperature and good air circulation.
T755(S)
Pro1 Technologies
P.O. Box 3377
Springfield, MO 65808-3377
Do not install
thermostat in locations:
• Close to hot or cold air ducts
• That are in direct sunlight
• With an outside wall behind
the thermostat
Toll Free: 888-776-1427
Hours of Operation: M-F 9AM - 6PM Eastern
• In areas that do not require
conditioning
• Where there are dead spots
or drafts
(in corners or behind doors)
• Where there might be
concealed chimneys or
pipes
Power Type
Thermostat Application Guide
Battery Power
Description
Hardwire (Common Wire)
Hardwire (Common Wire) with
Battery Backup
G
a
s
o
r
O
i
l
H
e
a
t
Yes
Yes
Yes
Yes
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Installation Tip
A trained, experienced
technician must install this
product.
Yes
Yes
Pick an installation location that is easy for
Heat Only Systems
the user to access. The temperature of the
location should be representative of the
building.
Cool Only Systems
Yes
Yes
Carefully read these
instructions. You could damage
this product or cause a
Millivolt
hazardous condition if you fail to
follow these instructions.
Table of Contents
Page
Subbase Installation
Installation Tips
Thermostat Quick Reference
Wiring
Wiring Diagrams
Features
2-3
4-5
6
7-9
10
Horizontal Mount
Vertical Mount
Una version en español de este
manual se puede descargar en
la pagina web de la compañia.
Installation Tip:
Electrical Hazard
Failure to disconnect the power before
beginning to install this product can
cause electrical shock or equipment
damage.
Technician Setup
Programming Thermostat
Specifications
11-19
20-23
24
Mercury Notice
All of our products are mercury free.
However, if the product you are
replacing contains mercury, dispose of
it properly. Your local waste
management authority can give you
instructions on recycling and proper
disposal.
For vertical mount put one screw on the top
and one screw on the bottom.
For horizontal mount put one screw on the
left and one screw on the right.
U.S. Registered Trademark. Patents pending
Copyright 2022 All Rights Reserved.
1
2
Rev. 2212
Installation Tips
Thermostat Quick Reference
Mount Thermostat
Getting to know your thermostat
Align the 4 tabs on the subbase with
corresponding slots on the back of the
thermostat, then push gently until the
thermostat snaps in place.
Menu
Battery Installation
Battery installation is optional if thermostat is
hardwired (R and C terminal connected to 24V
power).
Menu
Important:
High quality alkaline batteries are recommended.
Rechargeable batteries or low quality batteries
do not guarantee a 1-year life span.
Insert 2 AA
Alkaline batteries
(included). High
quality alkaline
batteries are
recommended.
LCD Display
Located ont he back of the thermostat.
Glow in the dark light button
About The Private Label Badge
All of our thermostats use the same universal magnetic badge. Visit the
company website to learn more about our free private label program.
Fan Button
System Button
Temperature Setpoint Buttons
User Buttons
Gently slide a screwdriver into the
bottom edge of the badge. Gently turn
the screwdriver counter clockwise. The
Use the bevel on lower ridge
Private Label Badge
badge is held on by a magnet in the well
of the battery door. The badge should pry
off easily. DO NOT USE FORCE.
Magnet in door
4
| General | Details |
|---|---|
| Name | PRO T755 Universal Thermostat Installation Guide |
| Make | Pro |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.43 MB |

PRO T751 Thermostat Installation Guide

PRO T755 Universal Thermostat Installation Guide Overview
Summary of Contents
- Page 1: Installation tips include selecting a location approximately 4 to 5 feet above the floor with average temperature and good air circulation. Avoid installing the thermostat close to air ducts, in direct sunlight, or with an outside wall behind it. Do not place the thermostat in areas that do not require conditioning or where there are dead spots or drafts. A trained technician must install the product, and the installation location should be easily accessible for the user. Carefully read the instructions to avoid damaging the product or creating hazardous conditions. Disconnecting power before installation is crucial to prevent electrical shock or equipment damage. All products are mercury-free, but if replacing a mercury-containing product, dispose of it properly. For mounting, use one screw on the top and one on the bottom for vertical mount, and one screw on the left and one on the right for horizontal mount. Battery installation is optional if the thermostat is hardwired, and high-quality alkaline batteries are recommended. The thermostat features a glow-in-the-dark light button and a universal magnetic badge for branding.
- Page 2: Thermostat quick reference Getting to know your thermostat Caution: Electrical hazard Failure to disconnect the power before beginning to install this product can cause electrical shock or equipment damage. If you are replacing a thermostat, make note of the terminal connections on the thermostat that is being replaced. The low battery indicator is displayed when the AA battery power is low. If the user fails to replace the batteries after an additional 21 days, the setpoints will change to 55˚F (Heating) and 85˚F (Cooling). This thermostat is hardwire powered when the 24V transformer is connected to the Common and RC terminals of the thermostat. Do not overtighten terminal block screws, as this can damage the terminal block. Use shielded or non-shielded 18-22 gauge thermostat wire. Max torque = 6in-lbs.
- Page 3: Wiring Diagrams Typical 2H/2C System: 2 Transformer Temporary and Permanent Hold Feature When cool or heat is turned on, the thermostat will display HOLD and RUN SCHED on the left of your screen when you press the or button. Temporary Hold: The temperature will remain at this setpoint temporarily for 4 hours. Permanent Hold: Press the HOLD key to see HOLD appear below the setpoint temperature in the display. To Return to Running Schedule: Press the RUN SCHED button to exit either temporary or permanent hold. Filter Change Reminder: You will see FILT in the display when your air filter needs to be changed. Resetting the filter change reminder: Hold down the second button from the top left side of the thermostat for 3 seconds. Technician Setup Menu: The swing setting is adjustable from 0.2˚ to 2˚. This thermostat has a technician setup menu for easy installer configuration. The cooling swing setting is adjustable from 0.2˚ to 2˚.
- Page 4: Tech settings provide various adjustment options for the thermostat. The LCD displays adjustment options and defaults for settings. You can select the number of heat and cool stages. A staging delay allows the previous stage extra time to satisfy the setpoint. The minimum compressor run time can be set to ensure the compressor runs for a specified duration. The system can be configured for different applications, including heat pump modes. The cooling fan delay setting helps save energy by controlling the fan operation. You can configure the thermostat for 7-day, 5+1+1 programming, or non-programmable options. Pro recovery allows early cooling to reach the programmed setpoint. Maximum heating and minimum cooling setpoint limits can be set to control temperature ranges.
- Page 5: Tech settings allow for various adjustments and configurations. The LCD will show adjustment options and defaults. You can enable the use of up to sixteen indoor sensors. Contractor call number can be displayed if selected ON. The thermostat energizes the Y terminal(s) only in calls for heat above the balance point. Balance point run time allows the W2 auxiliary terminal to energize even if the outdoor temperature is above the selected balance point. The local and remote temperatures can be averaged. Programmable thermostats come with an energy-saving pre-program that can be customized. You can set a maximum and minimum floor temperature limit for heat. Auto changeover allows switching between Auto Heat or Auto Cool modes.
- Page 6: Set program schedule 5+1+1 or 7 day. To customize your program schedule, follow these steps. All of our programmable thermostats are shipped with an energy saving pre-program. You can customize this default program by following the steps on page 16. Select heat or cool with the system switch. There are four time periods for each program (wake, leave, return, sleep). Use the table below to plan your customized program schedule. The display range of temperature is 41˚F to 95˚F (5˚C to 35˚C). The control range of temperature is 44˚F to 90˚F (7˚C to 32˚C). Operating humidity is 90% non-condensing maximum.