Package Contents  
Installation  
1 x Thermostat  
1 x Termostat mounting base  
1 x Mounting accessories  
2 x Alkaline batteries ΑΑ  
Operational Information  
emove the  
attery  
otective film.  
Burner indication  
Set  
temperature  
Low battery  
indicator  
Current  
temperature  
Burner indicator  
LED  
Decrease  
temperature key  
Increase  
temperature key  
1
2
BEFORE THE INSTALLATION  
Remove the protective film which is located in the right battery (Figure 2), the  
thermostat is activated.  
USINGTHE THERMOSTAT  
Ÿ Switch-on the thermostat bypressingany key.  
Ÿ To set the temperature, press any key. Decrease temperature key or Increase  
temperature key. The settemperature is displayed on the screen.  
Ÿ The thermostat is deactivated by pressing the two keys simultaneously for 2  
seconds. The set temperature will cease to appear while the room  
temperature is displayed.  
Live wire (L)  
230V~  
To burner (L)  
C
THERMOSTAT CALIBRATION(if required)  
NO  
The thermostat is factory calibrated, in case further calibration is required,  
follow the precedure below. Remove the batteries from the device. Hold down  
any key and re-install the batteries. The indication CAL and 0.0°C will displayed  
in the screen. Press the decrease/increase temperature key to set the  
temperature. To register the correct value, hold down the two keys until the  
save indicator appears on the screen.  
Risk of electric shock  
Disconnect the powersupplyprior installation of the thermostat.  
3
4
BATTERY REPLACEMENT  
If the symbol  
appears on the display, then the batteries must be replaced.  
Always use 2 new alkaline batteries of the same type and characteristics. Pay  
attention to the correct polarity. If the thermostat does not activate, remove the  
batteries and re-installed them, be sure to follow the symbols of the positive (+)  
and negative (-) poles of each battery.  
Do not reverse the polarity of the batteries and do not use rechargable  
batteries.  
Α
1.5m  
Dispose the old batteries for recycling, in compliance with current enviromental  
protection regulations.  
Ÿ
Ÿ
Ÿ
Wall mounting with recommended height: 1.5m from the floor on an  
internalwall.  
Do not mount the devices in recesses, shelves, behind curtains or doors,  
eitherabove or nearheat sources.  
Avoid directexposure to sunlight  
Β
ANTI-FREEZEPROTECTION  
If the room temperature value is 4.5οC, then the thermostat will enable the  
burner, regardless of the thermostat status. This mode remains active, as long as  
the temperature is below5οC.  
5
1
2
3
940830000_09_001  
940830000_09_001  
940830000_09_001  
GeneralDetails
Nameolympia electronics BS-830 Digital Electronic Thermostat Instruction Manual
Makeolympia electronics
LanguageEnglish
FiletypePDF (Download)
File size2.08 MB
Download PDF