OJ ELECTRONICS UTN5 OJ Microline Non Programmable Thermostat User Manual
7.6 FLOOR PROTECTION LIMITS
Floor protection limits:
This type of limit will override the heating/regulation if the floor temperature measured by the sensor exceeds the thresholds
set. If the temperature falls below the minimum threshold, the heating is switched on. If it rises above the maximum
threshold, the heating is switched off. This limit feature is only active in the “Floor” and “Room with floor limits” modes.
Press the select/accept
button for 3 seconds to
go to the Floor Protection
Press the up or down arrow to
scroll through the protection
options.
Press the select/accept
button to confirm the
setting.
Setting.
Floor protection limits
°C
°F
Min.
-
Max.
-
Min.
-
Max.
-
- OFF (floor protection is disabled)
- Wood (default)
- Laminate
5°C
5°C
5°C
27°C
28°C
40°C
41- °F
41- °F
41- °F
80- °F
82- °F
104- °F
- Tiles
25
Back to Content
© 2024 OJ Electronics A/S
| General | Details |
|---|---|
| Name | OJ ELECTRONICS UTN5 OJ Microline Non Programmable Thermostat User Manual |
| Make | OJ Electronics |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.66 MB |

OJ ELECTRONICS UTN5 Non Programmable Touch Thermostat Instruction Manual

OJ ELECTRONICS UDG-4999 Thermostat with Class A GFCI Owner’s Manual

OJ ELECTRONICS MWD5-1999-UAC3 Voice Control Wi-Fi Thermostat Instructions

OJ ELECTRONICS MWD5-1999-R3C3 Voice Thermostat Instructions

OJ ELECTRONICS MCD5 Touch Thermostat Instructions

OJ ELECTRONICS MCD3 Digital Thermostat Instructions

OJ ELECTRONICS UTN-4991 Non Programmable Thermostat Owner’s Manual