nVent GM-TA Thermostat User Manual
Installation
The GM-TA thermostat is intended for installation
within a distribution panel. The thermostat is to
be powered from a 230 Vac electrical supply in
accordance with local electrical regulations. The
heating cable and earthing connections need to be
made in accordance with the circuit wiring diagram
(figure C - last page).
Outdoor installaton of the GM-TA thermostat is
possible by using the nVent GM-TA-OUTDOOR-BOX
(PCN 1244-017966) with IP65 rating.
The GM-TA-AS sensor must be installed outside the
building and securely fastened to the wall (preferably
north facing) (figure B). The sensor must be connected
with a sensor cable (e.g. round 3 x 1,5 mm², max.
100 m) to the GM-TA thermostat.
Display
A-LED Display (temperature and alarm)
-Off: Heating cable OFF
0
-On: Heating cable ON
0
A
-Blinking: Post heating or Test
1-Program mode selection ON /OFF
2-Reduce value (change set temperatures)
3-Increase value (change of set
temperature)
4
|
nVent.com/RAYCHEM