OPERATION
Query Function of Temperature:
1. Press the Copy button for 3 seconds. P:00 will be displayed if connected to
a single indoor unit. If connected to multiple indoor units, press "\/" or "/\" to
display P:01, P:02, etc., then press Confirm to enter the query indoor unit Tn
(T1~T4) temperature and fan fault (CF). Press "\/" or "/\" to select.
2. If no operation is detected for 15 seconds or the Back button is pressed,
the system will exit the query temperature function.
3. When the unit is off, in the query function of temperature, press "\/" or "/\"
to select SP, and press Confirm to adjust the static pressure value.
4. When the unit is off, in the query function of temperature, press "\/" or
"/\" to select AF, and press Confirm to enter test mode. Press "Back", "On/
Off", or "Confirm" to exit test mode. In AF mode, the test completes after 3~6
minutes and automatically exits. If the test is in process, press "Back", "On/
Off", or "Confirm" to interrupt the test and exit.
Follow Me Function Temperature Compensation:
When the unit is off, in the query function of temperature, press "\/" or "/\" to
select tF. (tF = compensation temperature) The compensation temperature
range is 23°F~41°F (-5°C~5°C). Press Confirm to enter setting state, press "\/"
or "/\" to select the temperature, then press Confirm to complete.
When the unit is off, in the query function of temperature, press "\/" or "/\"
to select type. Press Confirm to enter setting state, press "\/" or "/\" to select
the type, then press Confirm to complete.