Home > MI-HEAT > Mi-Heat GH35EU Digital Greenhouse Thermostat User Manual

Mi-Heat GH35EU Digital Greenhouse Thermostat User Manual

Do not use the unit in an easily inflammable atmosphere (e.g. in the  
vicinity of fuel gas or spraybottles). Riskof explosion and fire!  
Never install the unit close to water cocks, washbasins or other water  
sources.  
Cultivationof plants and seeds  
Operatingmodes  
ENGLISH  
Position the sensor in the soil close to the roots. The sensor must be entirely  
surrounded by soil. In large plant pots the sensor should be located in the  
middle of thepot.  
Itis indicated bytheyellowLEDwhethertheheator cool mode is active.  
LEDs  
Operating mode  
red  
yellow  
green  
DIGITAL GREENHOUSE THERMOSTAT  
Do not insert any objects in the openings of the unit. Risk of injury, electric  
shock or damage to the unit!  
“Heat” mode selected /  
set temperature reached /  
heat mode off  
Watertemperaturecontrol  
on  
off  
off  
generallife.com.tr  
When assembling make sure that the connecting cable is not squeezed or  
damaged by sharp edges. If such damage gives rise to open points on the  
unit it must under no circumstances be connected to the mains supply.  
Danger!  
For water temperature control (e.g. in an aquarium), the sensor should be  
positioned in the central layers of water. Here too the sensor must be  
completely surrounded bywater.  
“Heat” mode selected /  
set temperature not reached/  
heat mode on  
on  
off  
off  
on  
off  
on  
off  
on  
on  
INSTALLATION AND OPERATING INSTRUCTION  
“Cool” mode selected /  
set temperature reached /  
cool mode off  
6. Operation  
Always pull the plug out of the socket before cleaning the unit. Only clean  
withadry cloth.  
When installing, check that the unit or mains cable is not damaged. Also  
make sure that the sensor cable has not become sharply kinked as this may  
impair operation.  
1. Scopeof supply  
1 pcs. Digital Thermostat GH-35 EU  
Incl. suspension device  
Removetheplug from thesocketwhenevertheunit is switched off.  
If it is to be assumed that harmless operation is no longer possible, the  
unit must be switched off and protected against unintentional operation,  
which is thecasewhen:  
“Cool” mode selected /  
set temperature not reached /  
cool mode on  
1
2
3
6
2.Technicaldata  
Display shows "---" with signal tone  
Interrupted working circuit or shortcircuit  
: GH-35 EU  
Type of unit  
– theunit or mains cable show visible damage  
Display shows "LLL" with signal tone Temperature below -50°C (or -58 F)  
Display shows "HHH" with signal tone Temperature above 99°C (or 210°F)  
/ heat mode off  
: 230 V / 50-60 Hz  
: 3000 W  
Powersupply  
– theunit no longer operates  
Max. breaking capacity  
Max. switching current  
Control range  
4
7
8
– afterbeing stored for along timeunder unfavourableconditions  
– afterheavytransport loads  
: 16A  
: 0 – 40°C / ± 0 – 90°F  
: ± 1°C / ± 1°F  
: -50°C to +99°C  
-58°F to 210°F  
: ± 1°C / ± 2°F  
: < 1,5 W  
7. Cleaning  
Units that operate on mains voltage should not get into the hands of  
children.  
5
Distinction rate  
Switchoff the thermostatbeforecleaning and removetheplug.  
Do not use any grinding, etching or cleaning agents.  
Measuring temperaturerange  
The unit is not suitable for use in cattlebreeding areas.  
These instructions for use form part of the unit and should be kept in a  
safe place. If the unit is passed on to third parties these instructions for  
use should also be provided.  
1
2
3
Cool LED  
Heat and cool mode on LED  
Heat LED  
6
7
8
Display / Temp indication  
Heat / cool mode  
On/Off button  
Clean the casing with a damp cloth (not wet), vacuum cleaner or feather  
duster.  
Switching accuracy  
Input  
Neverimmersethe unit in water. Danger!  
If the unit is not used for a long time it is necessary to protect it from  
excessivedust and dirt.  
4-5 Temperature selection buttons  
: II  
Protection class  
Protectivesystem  
Sensor length  
In industrial installations the accidentpreventionregulations of the  
Industrial Professional Association for Electrical Installations and  
Equipment must be complied with.  
: IPX4  
Switching on/off  
: approx.110 " /2.8m  
As soon as the unit has been connected to the supply voltage it can be  
switched on by means of the “ON/OFF” button. To do this, the button must  
8. Disposal and repair  
Never pour liquids over the unit as this presents the risk of a fire or‚ fatal  
electric shock. If this should happen, however, pull the plug out of the  
socketand consult aspecialist.  
IMPORTANT:  
Take units to be disposed of to a suitable waste  
reception depot only.  
be pressed for  
3
seconds. Immediately after switching on, the unit  
Read carefully and follow these instructions as well as the general  
advice on safety and risks before installation. Keep this leaflet in a  
safe place for future reference. If you have any doubt about the safety of the  
unit seek the advice of an expert. If the unit is used in a greenhouse make  
surethatthe electricalconnections arecarriedout byqualified personnel.  
determines the ambient temperature of the sensor and indicates it on the  
display. To switchoff, again presstheON/OFFbutton for 3 seconds.  
Repairs to the unit may only be carried out by  
authorised specialists. Please therefore consult  
themanufactureror dealer.  
If you are uncertain about correct connection, or if you haveany questions  
which are not clarified in the course of the instruction, contact the  
manufactureror aspecialist.  
Heat/Cool mode  
N.B. If the unit is not correctly repaired the  
warrantywillnot be valid.  
Itis possible to switchbetweenthe heatand cool mode bypressing the  
This unit is not intended for use by persons (including children) with  
limited physical, sensory or mental capacity. This also applies to persons  
who do not have sufficient experience in or knowledge of handling the  
product, unless they are being supervised or instructed in the use of the  
unit byaperson responsible for theirsafety.  
button. Keep the  
button pressed for 3 seconds to change mode. On the  
3. General  
Incorrectly carried out repairs may represent a  
danger to theuser and other people.  
display “H” appears for 4 seconds for heating and “C” for cooling. At the  
same time you can detect the mode that has been set by means of the the  
red LEDstands for heating and the green LEDfor cooling.  
After unpacking and before switching on, make sure that the unit and all its  
accessories are perfectly in order. If there has been any damage in transit,  
consult your dealer or the manufacturer immediately. Keep the packaging  
materials (polythene bag, polystyrene, nails etc.) out of reach of children  
because they represent a potential source of danger. This also applies to  
small parts supplied, which can be swallowed. This electronic thermostat  
can be used for a wide variety of temperature control applications, for  
example for heating and cooling greenhouses and winter gardens, or for  
monitoring water temperatures in aquariums, the air temperature in  
terrariums or the soil temperature in seed beds. It is simple to operate and  
can be connected to any type of heating cable, heating mat or other heating  
or cooling devices, provided that the maximum heating power of 3000 W is  
not exceeded. This thermostat is only licensed for connection to 230 V,  
50/60Hz voltage. The unit must be protected from high degrees of  
contamination and moisture. If it is used for any application other than that  
described above it may be damaged and risks such as short-circuiting, fire,  
electric shock etc. may ensue. The safety and installation in-structions  
must be strictlyadhered to.  
9. Servicing and maintenanceunderwarranty  
We give you a 2 year unlimited manufacturerʼs warranty (from date of  
purchase) on all Isıpark products. Excluded from the warranty is damage  
due to violence, improper use and failure to follow instructions for use,  
cleaning and maintenance work.  
5. Installation  
Settingtherequired temperature  
Make sure that the mains voltage corresponds to the voltage  
indicated in Chapter 2 (technical data). The place of installation  
must be chosen so that the unit can under no circumstances get  
Press the  
or button briefly to switch to the setting mode. The already  
and buttons  
set temperature now flashes in the display. Using the  
you can change the temperature in 1oC / 1°F steps. (Setting range -50°C to  
+99°C / -58°F to +210°F). After you have set a new temperature, it is saved  
automatically and the menu closes after 3 seconds. Now the display again  
shows thecurrentambient temperature.  
The manufacturer accepts no liability for damage due to frost, insufficient  
heating power related to the room dimensions, or due to inadequate heat  
insulation.  
wet(e.g. dripping condensation, open roof hatches, etc.)or fall into water.  
The thermostatmaybe operated in ahorizontalor vertical position.  
1. Connect the heating or cooling  
Important note  
Celsius/Fahrenheit unit selection  
The unit may only be opened and repair work may only be carried out by  
licensed specialists in accordance with the applicable repair regulations.  
Only original parts maybe fitted.  
unit to the thermostat. To do so,  
Under normal running status, short press key or  
release it, it enters to temperature setting state, and it blinkingly displaysthe  
current set temperature. Atthis time, hold and press “ ” keyfor more than  
key and immediately  
1
insert the plug of the corresponding  
heating or cooling unit in the socket  
on thethermostat.  
A guarantee of perfect operation and reliability can only be givenif the unit is  
installed and handled expertly. This also applies to the provisions of the  
Technical Equipment Act and the applicable accident prevention  
regulations.  
5 seconds , the system enters Celsius and Fahrenheit setting state, LED  
blinkingly flashes C and F. Switch between Celsius and Fahrenheit. When  
finish setting, it will exit in 3s if there is no key operation, and return to the  
normal running stateand savetheparametersautomatically.  
2. Now connect the connecting  
cable of the thermostat to a 230 V  
mains socket.  
4. Adviceonsafetyand risks  
In case of warranty please complete the warranty and info card attached for  
this purpose.  
Only a 230 V, 50/60Hz mains socket in the public supply network  
may be used as a power source. Never try to operate the unit at a  
differentvoltage.  
3. Position the end of the sensor  
cable at the most suitable point for  
temperaturecontrol.  
If you have any further questions refer to our ISIPARK:  
Tel.: +90 (850) 441 55 66 or Email: info@isipark.com.tr  
Consult an expert if you have any doubts about the operation, safety or  
connection of theunit.  
This unit mayonly be used indoors.  
Room temperaturecontrol  
When opening the cover or removing parts, the unit must be disconnected  
from themains supply.  
The sensor should be installed at  
half room height and should be  
freely suspended. The room  
temperature can only be optimally  
controlled when the sensor is not  
Neverswitchthemains plug on or off withwethands.  
Never pull on the mains cable itself, always pull the plug out of the socket  
bythegripping surfaces.  
2
influenced by draughts, solar  
radiation or other heat or cold  
sources.  
2
1
3
4
GeneralDetails
NameMi-Heat GH35EU Digital Greenhouse Thermostat User Manual
MakeMI-HEAT
LanguageEnglish
FiletypePDF (Download)
File size1.96 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Mi-HEAT M2 Wi-fi Bluetooth Thermostat Instruction Manual
Mi-HEAT M2 Wi-fi Bluetooth Thermostat Instruction Manual
MI-HEAT E51 Thermostat User Manual
MI-HEAT E51 Thermostat User Manual
MI-HEAT MST1 Room Thermostat for Underfloor Heating User Manual
MI-HEAT MST1 Room Thermostat for Underfloor Heating User Manual
MI-HEAT MTS200 WiFi Thermostat Instruction Manual
MI-HEAT MTS200 WiFi Thermostat Instruction Manual
MI-HEAT WT8 WiFi Smart Thermostat User Manual
MI-HEAT WT8 WiFi Smart Thermostat User Manual

Mi-Heat GH35EU Digital Greenhouse Thermostat User Manual