PRODUCT’S PRESENTATION  
Machine designed for perfect washing of dirty parts.  
It includes a pneumatic gun to clean with solvent and can also be used to dry the parts  
using compressed air.  
Thanks to its closed cabin, the operator is completely protected from splashes and  
odour of the solvent.  
It has a thermostat with which you can adjust the temperature level of the cleaning  
liquid and light inside the tank for better visualization.  
SAFETY INSTRUCTIONS  
The owner's manual is a crucial resource for understanding product safety, warnings,  
and precautions, as failure to follow could lead to personal injury or property damage.  
WARNING! Maintain a safe working environment by controlling bench deviation, keeping work  
areas clean, keeping children away, using appropriate tools, using organic cleaning solvent,  
and using protective gloves.  
Before servicing or changing accessories, disconnect parts washer.  
Make sure the heating switch is OFF before turning on the machine.  
Do not activate the heating if the solvent volume is less than 8 liters.  
Do not use the machine if the lid is open.  
Do not use solvent which ignition temperature is lower than 120ºC.  
Do not set the operating temperature above 50ºC.  
TECHNICAL SPECIFICATIONS  
Tank capacity: 8-14L  
Air flow: 70-120 PSI@5CFM  
Cleaning agent flow rate: 0.8L/min  
Thermostat maximum temperature: 50ºC  
Tank dimensions: 74x56x45.2cm  
Dimensions: 790x1710x610mm  
Weight: 46Kg.  