HEAT PUMP THERMOSTAT  
SETTINGS  
CHECKOUT  
Temperature Setting  
Heating  
The enlarged, raised numbers on the right edge of the  
thermostat can be used for easy temperature setting by  
touch or sight while moving the temperature setpoint  
lever to the desired temperature setting. The large 5, 6, 7  
and 8 refer to 50°F (10°C), 60°F (16°C), 70°F (21°C) and  
80°F (27°C), respectively. A click is heard with indents  
every two degrees as the temperature setpoint lever is  
moved. See Fig. 1.  
Move the System switch on the thermostat to HEAT and  
the Fan switch to AUTO. Move the temperature setpoint  
lever to about 10°F (6°C) above the room temperature.  
Heating should start and the fan should run. Move the  
setpoint lever about 10°F (6°C) below the room  
temperature. Heating and fan should shut off.  
IMPORTANT  
To prevent compressor short cycling, a mini-  
mum-off timer can be included to prevent the  
compressor from starting for up to five minutes  
from when the thermostat last turned off the  
compressor, or from when the system first  
received power.  
System Switch Setting  
The enlarged, raised letters on the left bottom edge of the  
wallplate can be used for easy recognition of System  
switch settings:  
For the T841A Thermostat: The large EH, H, O and C  
refer to EM. HT., HEAT, OFF and COOL.  
For the T841B Thermostat: The large H, O and C refer  
to EM. HT., HEAT, OFF and COOL.  
Cooling  
The System switch settings control the system operation  
as follows:  
CAUTION  
Compressor Damage Hazard.  
Operating cooling equipment in cold weather  
can damage compressor.  
EM.HT (only on T841A): Emergency heat relay is  
energized. Cooling system is off. Compressor is  
de-energized. Fan runs on call for heat if the Fan  
switch is in the AUTO position. EM. HT. LED is on.  
HEAT: Heating system is automatically controlled by  
the thermostat. Cooling system is off.  
OFF: Both the heating and cooling systems are off. If  
the fan is set to the AUTO position, the cooling fan  
is also off.  
Do not operate air conditioner if outdoor  
temperature is below 50°F (10°C).  
Move the System switch on the thermostat to COOL and  
the Fan switch to AUTO. Move the temperature setpoint  
lever about 10°F (6°C) below the room temperature.  
Cooling and fan should start (see Note in Checkout  
section). Move the setpoint lever about 10°F (6°C) above  
the room temperature. Cooling and fan should shut off.  
COOL: Cooling system is automatically controlled by  
the thermostat. Heating system is off.  
Fan Switch Setting  
Fan  
On theT841A,B, large A, O raised letters on the right  
bottom edge of the wallplate refer to AUTO and ON fan  
settings. The Fan switch settings control the fan as  
follows:  
Move System switch to OFF, and Fan switch to ON. The  
fan should run continuously. Move Fan switch to AUTO.  
In this position, the fan operates in response to the  
thermostat in both heating and cooling.  
AUTO: Fan operates in response to thermostat in both  
heating and cooling.  
ON: Fan operates continuously.  
Automation and Control Solutions  
Honeywell International Inc.  
1985 Douglas Drive North  
Golden Valley, MN 55422  
Honeywell Limited-Honeywell Limitée  
35 Dynamic Drive  
Scarborough, Ontario  
M1V 4Z9  
Printed in U.S.A. on recycled  
paper containing at least 10%  
post-consumer paper fibers.  
69-1043-2 G.H. Rev. 3-03  
GeneralDetails
NameHoneywell T841A,B Easy-To-SeeTM Heat Pump Thermostat Instruction Manual
MakeHoneywell
LanguageEnglish
FiletypePDF (Download)
File size0.25 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TL116A Thermostat Installation Guide
Honeywell TL116A Thermostat Installation Guide
T10 Pro Smart Thermostat with Redlink Room Sensor
T10 Pro Smart Thermostat with Redlink Room Sensor
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide

Honeywell T841A,B Easy-To-SeeTM Heat Pump Thermostat Instruction Manual