Honeywell T4098A Deluxe Electric Heat Thermostat Instruction Manual
T4098A,B DELUXE ELECTRIC HEAT THERMOSTATS
FRONT VIEW
SIDE VIEW
2-5/8 (67)
CAUTION
1. Disconnect power supply to prevent electrical
shock or equipment damage.
2. If connecting with aluminum conductors, use CO/
ALR solderless wire connectors to avoid fire
hazard.
2-1/8
(54)
3. Do not remove thermostat cover until wiring is
complete to avoid damaging the sensing element.
4-1/2
(115)
4-1/2
(115)
Location
Install a vertical outlet box that is used to mount the
thermostat about 5 ft (1.5m) above the floor in an area with
good air circulation at room temperature.
1
(25)
2-7/8 (73)
1-3/4
(45)
M5790
Do not install the thermostat where it may be affected by:
—
drafts or dead spots behind doors, in corners or under
cabinets.
hot air from convectors.
Fig. 1.T4098 dimensions in in. (mm).
—
—
—
—
radiant heat from sun or appliances.
concealed pipes and chimneys.
unheated (uncooled) areas such as an outside wall
behind the thermostat.
RECYCLING NOTICE
If this control is replacing a control that contains
mercury in a sealed tube, do not place your old
control in the trash.
Wiring and Mounting
Contact your local waste management authority for
instructions regarding recycling and the proper
disposal of an old control containing mercury in a
sealed tube.
CAUTION
1. Handle the thermostat with care to avoid
damaging the sensing element or control.
2. Use a separate limit control in the heating
appliance.
L2
2
T4098A
INSTALLATION
1
3
L1
L1
(HOT)
When Installing this Product…
1. Read these instructions carefully. Failure to follow these
instructions could damage the product or cause a
hazardous condition.
T1
2. Check the ratings on the product to make sure the
product is suitable for your application.
3. Installer must be a trained, experienced service
technician.
4
4. After installation is complete, check out product
operation as provided in these instructions.
ELECTRIC
HEATER
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
1
2
WARNING
HIGH VOLTAGE CONTROL.
ELECTRICAL SHOCK HAZARD.
Follow local codes and ordinances when installing this
thermostat. Improper handling can cause serious
injury or death.
USE SPECIAL SERVICE CO/ALR SOLDERLESS CONNECTORS
WHEN CONNECTING ALUMINUM CONDUCTORS OR A FIRE
HAZARD MAY RESULT.
3
4
BREAKS AND REMAKES BELOW -31°F(-35°C); NORMALLY
THERMALLY ACTIVATED. BREAKS ON A TEMPERATURE RISE;
MAKES ON A TEMPERATURE FALL.
USE A SEPARATE LIMIT CONTROL IN THE HEATING APPLIANCE.
M5813B
Fig. 2.Typical wiring connections for T4098A.
3
68-0146—3
firealarmresources.com
| General | Details |
|---|---|
| Name | Honeywell T4098A Deluxe Electric Heat Thermostat Instruction Manual |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.14 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell D1-528 Direct Thermostat Installation Guide

Honeywell FocusPRO P200 Programmable Thermostat User Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide