Honeywell RTH7500 7-Day Programmable Thermostat Installation Guide
RTH7500 Series
Number
Description
Options (factory default in bold)
0 = O (O/B in Cool)
1 = B (O/B in Heat)
Note: This option is only displayed if the Heat Pump configured. Select
whether reversing valve O/B should energize in cool or in heat.
218
Reversing Valve O/B
0, 1, 2
Cool Stages / Compressor
Stages 200=Conv / 200=HP
Note: Select how many Cool or Compressor stages of your equipment
the thermostat will control. Maximum of 2 Cool/Compressor Stages. Set
value to 0 if you do not have Cool Stage/Compressor Stage.
220
221
Heat Stages: 1, 2
Backup Heat Stages: 0, 1
Note: Select how many Heat or Aux/E stages of your equipment the
thermostat will control. Maximum of 2 Heat Stages for conventional
systems. Maximum of 1 Aux/E stage for systems with more than 1
heating equipment type. Set value to 0 if you do not have Heat Stage/
Backup Heat Stage.
Heat Stages / Backup Heat
Stages Heat Stages
0 = Manual
1 = Automatic
Note: Thermostat can automatically control both heating and cooling
to maintain the desired indoor temperature. To be able to select
“automatic” system mode on thermostat home screen, turn this feature
ON. Turn OFF if you want to control heating or cooling manually.
300
System Changeover
Smart Response
0 = No
1 = Yes
425
Note: Smart Response is a comfort setting. Heat or Cooling equipment
will turn on earlier, ensuring the indoor temperature will match the
setpoint at the scheduled time. See page 15.
50 °F to 99 °F (50 °F)
10.0 °C to 37.0 °C (10.0 °C)
Note: The cool temperature cannot be set below this level.
Minimum Cool Temperature
Setpoint
430
431
40 °F to 90 °F (90 °F)
4.5 °C to 32.0 °C (32.0 °C)
Note: The heat temperature cannot be set above this level.
Maximum Heat Temperature
Setpoint
0 = Off
10 = 45 Calendar Days
11 = 60 Calendar Days
12 = 75 Calendar Days
13 = 3 Calendar Months
14 = 4 Calendar Months
15 = 5 Calendar Months
16 = 6 Calendar Months
17 = 9 Calendar Months
18 = 12 Calendar Months
19 = 15 Calendar Months
1 = 10 Run Time Days
2 = 20 Run Time Days
3 = 30 Run Time Days
4 = 45 Run Time Days
5 = 60 Run Time Days
6 = 90 Run Time Days
7 = 120 Run Time Days
8 = 150 Run Time Days
9 = 30 Calendar Days
Air Filter 1 Replacement
Reminder
711
Note: Set a reminder for when to change your air filter. Choose either
calendar or equipment run time-based reminder.
0 = Off
1 = On
1415
Daylight saving time
Note: Set to Off in areas that do not follow Daylight Saving Time.
NOTE: Once you have cycled through all of the System Setup numbers, Done is
displayed. Press Select to save and exit.
9
| General | Details |
|---|---|
| Name | Honeywell RTH7500 7-Day Programmable Thermostat Installation Guide |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.84 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell D1-528 Direct Thermostat Installation Guide

Honeywell FocusPRO P200 Programmable Thermostat User Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell RTH2300 Thermostat User Guide