Honeywell FocusPRO P200 Programmable Thermostat User Guide
System Operation Settings
1
Press the MODE button to cycle to the next
available System mode.
MODE
Indoor
Heat
2
Cycle through the modes until the desired
System mode is displayed.
MENU
Hold
FAN
Auto
Available System modes vary by model and
system settings.
System modes:
MCR39511
• AUTO
• HEAT
• COOL
• EM HEAT
•
OFF
Fan Operation Settings
1
Press the FAN button to cycle to the next
available Fan mode.
MODE
Indoor
Heat
2
Cycle through the modes until the desired
Fan mode is displayed.
MENU
Hold
FAN
Auto
Available Fan modes vary with system settings.
Fan modes:
MCR39512
• AUTO: Fan runs only when the heating or
cooling system is on
• ON: Fan is always on
•
CIRC: Fan runs about 33% of the time to
circulate air
Auto Changeover
When a thermostat is set to Auto Changeover, the thermostat has a Heat setpoint and a Cool setpoint and can
run either Heat or Cool as needed.
1
Verify the thermostat is set to Auto Changeover mode. Press the MODE button in the upper left until AUTO is
selected. Press the SAVE button (Center left).
2
Press the or button. Upper right shows HEAT TO or COOL TO in flashing text, and the setpoint. Use the
or button to adjust the setpoint. If the display shows HEAT TO flashing when you want to adjust the Cool
setpoint, or vice versa, press the System button. While HEAT TO or COOL TO is flashing, the mode indication
at upper left shows either HEAT or COOL flashing. Pressing the MODE button at this time changes the
setpoint being adjusted from HEAT to COOL or vice-versa.
Heat and cool set to the same temperature
Most people are comfortable in a 2–3 degree temperature range. Therefore, the heat is usually set a few degrees
below the Cool setpoint. When the indoor temperature is between the Heat and Cool setpoints, the system is off.
The Heat and Cool setpoints can be the same. To ensure that the system doesn’t cycle back and forth between
Heating and Cooling, the thermostat observes a differential setting, set by the installer. If the thermostat last ran
in Heat mode, it cycles heat on and off to maintain the setpoint. The indoor temperature must rise to the
differential setting before it switches to Cool.
Then cooling will run down to the Cool setpoint and cycle cooling on and off to maintain as needed. The
thermostat would then need to drop to the differential setting before switching back to Heat. Typically, a
thermostat using Auto Changeover would only need to switch over twice per day as outdoor temperature rises
during the day and drops in the evening.
4
| General | Details |
|---|---|
| Name | Honeywell FocusPRO P200 Programmable Thermostat User Guide |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.93 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell D1-528 Direct Thermostat Installation Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide

Honeywell Smart Color Touchscreen Programmable Thermostat RTH9590 User Manual