GV S603R-3A Programmable Digital White Thermostat User Manual
» SETTING THE TIME AND DAY OF THE WEEK
VIII - ADVANCED SETTINGS
button to enter the advanced settings menu. Press the button
move to the next settings.
With the thermostat on, press the button
the + and - buttons to set the time.
. The Hour digits will blink. Use
to
Press the button again to move to the minutes and use the + and -
buttons to set the minutes.
» SEN - PROBE SELECTION
the number 1 representing Monday, 5 representing Friday, 6 representing
Saturday and 7 representing Sunday.
If option 02 is set (both probes in use), the thermostat display in normal
operation shows only the temperature of the ambient probe. To check the
» TOGGLE BETWEEN MANUAL AND AUTOMATIC MODE
With the thermostat on, press the button
quickly to switch between
-
manual and automatic mode. In manual mode you will see the symbol
the display and in automatic mode you will see the programming that is
on
ously press the button
.
active (
).
» OSV - FLOOR PROBE LIMIT TEMPERATURE
» SET TEMPERATURE IN MANUAL MODE
With the thermostat turned on in manual mode, use the + and - buttons to set
the temperature.
Use the + and - buttons to set the value that can range from 5ºC to 99ºC. The
factory set value is 42ºC.
The thermostat turns on when the temperature of the probe is lower than the
one set at 1.5ºC and the symbol
appears on the screen. This symbol means
» DIF - TEMPERATURE DIFFERENTIAL ASSOCIATED WITH THE LIMIT OF THE
probe temperature is higher than the one set at 1ºC.
FLOOR PROBE
» DAILY AND WEEKLY SCHEDULE
This thermostat supports 6 daily and 3 weekly programs (6 programs from
Monday to Friday and two programs for Saturday and Sunday, or 6 programs
from Monday to Saturday and two for Sunday or 6 programs from Monday to
Sunday).
this option and set 40ºC in the previous function, the thermostat will switch
value that can range from 1ºC to 9ºC. The factory set value is 2ºC.
» SVH - HIGH TEMPERATURE LIMIT FOR ROOM TEMPERATURE
Period
Icon
Default Time
06:00
Default Temperature
1
2
3
4
5
6
1
2
20 ºC
15 ºC
15 ºC
15 ºC
22 ºC
15 ºC
22 ºC
15 ºC
08:00
this temperature. Use the + and - buttons to set the value that can range from
5ºC to 99ºC. The factory-set value is 35ºC.
11:30
Week
12:30
» SVL - LOW TEMPERATURE LIMIT FOR ROOM TEMPERATURE
17:30
22:00
08:00
this temperature. Use the + and - buttons to set the value that can range from
5ºC to 99ºC. The factory set value is 5ºC.
Weekend
23:00
Press the button for 5 seconds and you will see the days of the week (
), use the + and - buttons to select the type of programming you
» ADJ - CORRECTION OF THE AMBIENT PROBE TEMPERATURE
This function allows to correct the temperature of the ambient probe. This
correction is applied when the temperature displayed by the room probe is
not equal to the actual room temperature (measured with another external
device). This can happen due to the installation or position of the thermostat.
Use the + and - buttons to set the value. The factory-set value is 0ºC.
desire:
-
-
-
: 6 programs for the week plus 2 programs for the weekend
: 6 programs from Mon. to Saturday plus 2 programs for Sunday
: 6 programs from Monday to Sunday.
» FRE - ANTI-FROZEN
This function allows to activate or deactivate the anti-frozen function. With
this function active, the thermostat starts automatically when the tempera-
Press the button
ture.
again quickly and you will have the temperature of the
-
If you want to change the start time of the program press the button
and
means that the function is on. The factory setting is 0.
buttons to set the program start minutes. Press the button
to the temperature.
again to return
» PON - MEMORY FUNCTION IN CASE OF POWER FAILURE
memorize its settings in the event of a power failure. A value of 0 means that
setting is 0.
Press the button
quickly to go to the next program and repeat the process
programmed to start at 10:00 , the second cannot start at 09:00.
NOTE 2: There is no opening and closing of the daily programming period. If
you do not want heating for some time, you must set a temperature low
enough so that the thermostat does not start.
» FAC - DEFINIÇÕES DE FÁBRICA
This function allows you to reset all settings and functions to the factory
values. Use the + and - buttons to set the value. 00 will reset all values to
factory defaults. If you do not want to make changes, select the value 08.
NOTE 3: During programming, if you do not press any button for 15 seconds,
you will exit programming mode.
IX - ERROR TABLE
NOTE 4: When the thermostat is operating in automatic mode, you can
manually change the temperature set for that daily period using the + and -
Erro
ERR
Cause
Floor probe error
Solution
Replace floor probe
automatic mode are canceled when is started a new daily period.
VAC Ltd.
: Globovac Ltd, 8C Castle Road, Chelston
Park, Wellington, Somerset
Q, United Kingdom
» CHILD LOCK
With the thermostat on, press the button
thermostat.
ort: +44 (0) 1293 768 210
ostumers: +44 (0) 1293 772 165
for 5 seconds to lock / unlock the
ww.globovac.com
| General | Details |
|---|---|
| Name | GV S603R-3A Programmable Digital White Thermostat User Manual |
| Make | GV |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.47 MB |