Home > GENERAL LIFE > GENERAL LIFE HT300 RF Digital Room Thermostat User Manual
GENERAL LIFE HT300 RF Digital Room Thermostat User Manual
WEEKLY PROGRAM
You may set the operating schedule of your Room Thermostat with weekly program
CoolingMode
WARRANTY CONDITIONS
1-The warranty period starts from the invoice date and warranted against
manufacturing defectsfor2 years.
WARRANTY CERTIFICATE
Your room thermostat takes the average room temperature of last 40 seconds as
basis. With the TPI algorithm in the product by creating a general temperature map
of your home, it learns how long it takes to reach the desired room temperature and
how this temperature is maintained. Thus, it ensures that the room temperature
remainswithin acertain range.
mode.
7
different temperature values can be set for each day in weekly
programming. Thesevaluescan be setin temperatureadjustmentscreens'' P0-P6''.
2-Devices and apparatus are delivered to the customer in working condition in our
company. On-sitecommissioning is subjectto aservice fee.
Manufacturer
In order to set the weekly schedule, press and hold the “Weekly Program“ button
for 3 seconds while your Room Thermostat is on. The “Hour, Minute and Day”
setting will appear. Press the “Heating & Cooling Option” button until the “Weekly
Program”menu (P0)appears.
Title: ISIPARK İÇ DIŞ TİC. A.Ş.
Adsress: Fatih Mah. 1188 Sk. No:13/A Sarnıç
Gaziemir İzmir-TÜRKİYE
3-The repair of the devices and apparatus covered by the warranty is carried out in
our company factory and should send bycontracted transportation company. In on-
site services, the transportation and accommodation expenses of the service
personnel belong to the customer. The shift fee during transportation is added to
theservice feeand collectedin advance.
TPI ROOM THERMOSTAT COOLING MODE WORKING GRAPHIC
Days of the week will be blinking on the screen. You can initiate the weekly
programsettingif youwish to setthesameschedule for everydayof theweek.
Pressthe “Up“ button once if youwish to set the same schedule for the weekdays.
Firstfivedaysof weekwillbe blinking on thescreen.
TEMPERATURE (ºC)
Desired Temperature
TPI Room Thermostat
Tel: +90 (232) 457 99 50
30
Fax: +90 (232) 457 91 22
4-The maintenance of devices and apparatus is done in our company. For the
maintenance of the devices and apparatus, the round travel fares belong to the
customer.
E-Mail: generallife@generallife.com.tr
Authorised Signatory:
Press the “Up“ button once more if you wish to set the same schedule only for the
weekend. Lasttwodaysof theweekwillbe blinking on thescreen.
Press the “Up“ button one more time if you wish to set the same schedule for
every day of the week. 1st day of the week will be blinking on the screen. You can
switch between the days by pressing the “Up“ button. Press the “Down“ button in
orderto switchto thepreviousday.
5-In case of malfunctioning of the devices and apparatus whose warranty period
continues, it is tested in our company whether the malfunction is caused by a
customer or manufacturer fault, and it is reported with a report issued by our
company.
Company Stamp:
23
6-In case of detection of manufacturer-induced errors of devices and apparatus
whose warranty period continues, the customer can request a replacement or
repair of the devices and apparatus at full expense by the manufacturer, unless it's
higher than theproduct's price.
Product
Type: Digital Room Thermostat
Brand: GENERAL Life
Pressthe“WeeklyProgram“button once to setaschedule.
“P0” will be blinking on the screen. Set the temperature value of “P0” by pressing
the “Weekly Program“ button once more. The hour setting of “P0” cannot be
changed since it's factory setting.
5
Time
Your Room Thermostat sends the last status signal to the Receiverevery6 minutes.
Thus, yourRoom Thermostat and Receiverwork synchronously. If the signal cannot
reach to the Receiver from the Room Thermostat for 22 minutes, it perceives that
the connection is broken and stops the heating/cooling operation for safety
reasons. Likewise, in cases where the electricity comes back after a power failure,
the Receiver does not operate the heating/cooling unit until 'operate' signal reaches
from the Room Thermostat. However, in this case, if the Room Thermostat
continues to operate normally, it will continue to work properly without any need for
intervention since itsends astatussignal to theReceiverevery10minutes.
7-In the event that the faults of the devices and apparatus whose warranty period
continues are determined as caused by the customer, all expenses would belong to
thecustomer.
Model: HT300 RF/HT300S RF
Guarantee Period: 2 Years
Max. Time to Repair: 20 Days
Banderole and Serial Number:
Press the “Weekly Program”button again. Day indicator will be blinking. If you will
not change the day, press the “Weekly Program” button again and switch to the
“P1” settingbypressingthe“Up” button.
8-Customers should be aware of damages (if there is any) of product and warn
manufacturer since the day warranty duration starts. If customer do not warn
manufacturerwithknowledge of damage, customerlose therights of article 6.
9-Malfunctions resulting from the use of devices and apparatus contrary to the
mattersstatedin theUserManual arenot coveredbythewarranty.
10-Devices and their apparatus are out of warranty if they are beaten, broken or
scratchedbythecustomer.
First, hour setting will appear on the screen. Once you complete the hour setting,
adjust the minute setting by pressing the “Weekly Program” button. After the
minute setting, pressthe“WeeklyProgram”button to setthetemperaturevalue.
Follow thesamestepsfor other schedule settings.
Once all changes made, press and hold the “Weekly Program” button for
seconds to save.
3
WHATTO KNOW ABOUTTPI ROOM THERMOSTAT
Note: In order to check the weekly schedule which has been set without making any
changes, press the “Weekly Program” button once while your Room Thermostat is
on. Press the “Up” and “Down” buttons to see the days, press the “Mode” button to
seethesettingsbetween“P0-P6”.
11-Damages resulting from the use of devices and apparatus belonging to other
brands and models without the approvalof the manufacturer are not coveredby the
warranty.
If the placement of the TPI Room Thermostats is changed, the learning process
willrestart. The learning processshould be consideredas7 days.
If the TPI Room Thermostats arede-energized(battery replacement), the learning
processwillrestart. The learning processshould be consideredas7 days.
12-Battery leakage and errors due to rust, oxidation and liquid contact by working in
acidic/ humid environmentsarenot coveredbythewarranty.
TPI ROOM THERMOSTAT WORKING LOGIC
13-When the product is not used for a long period (more than 15 days), remove the
batteries. Otherwise, malfunctions thatwilloccur areout of warranty.
14-Damages that may occur during the transportation of devices and apparatus are
not coveredbythewarranty. Customers can taketransportation insurance.
15-Damages caused by mains voltage / faulty electrical installation are not covered
bythewarranty.
FREQUENTLY ASKED QUESTIONS
IsmyRoom Thermostatcompatible withmyheating/cooling unit?
Your Room Thermostat works with the TPI algorithm. Room Thermostats using TPI
technology predict when the temperature of your home will rise above or below the
set temperature and turn the heating / cooling unit on and off accordingly. This
ensures that your home stays at the temperature you set without maximum
deviationsup and down.
If your heating/cooling unit has On-Off connections, your Room Thermostat is
compatible. You can find information about your heating/cooling unit from your
heating/cooling unit operating manual or fromyourheating/cooling unit service.
Vendor
Title:
How willIconnect myheating/cooling unit withmy Receiver?
What is TPI?
16-Devices and apparatuses are out of warranty for malfunctions caused by force
majeuresuch asfire, flood, and earthquakeetc.
We recommend that the connection between the Receiver and heating/cooling unit
should be made byprofessionally qualified persons.
TPI technology is designed to ensure that you get the best possible energy
efficiency from your heating / cooling system. It measures and applies the best
possible timings to deliverand maintain yourhome atthesettemperaturelevel.
17-All of the devices and apparatuses, including all their parts, are under the
warrantyof our company.
Address:
2x0.75mmcableis sufficientfor theReceiver– heating/cooling unit connection.
Connect one end of the cable pair to the room thermostat connection terminals
statedin theuser manual of yourheating/cooling unit.
How does TPIwork?
18-In case of malfunction of the devices and apparatuses within the warranty
period, the time spent during repair period is added to the warranty period. The
repair period of the product cannot exceed 20 working days. This period starts from
the date of notification to the service station of the malfunction related to the
Thanks to the advanced artificial intelligence technology found in the software, it
adapts to the temperature change of the environment in which it is located. By
creating a general temperature map of your home, it learns how long it takes to
reach the desired room temperature and how to maintain this temperature. In this
way, it provides minimum energy consumption by calculating how long your
heating / cooling unit should workfor.
Tel:
Fax:
Connect the other end of the cable pair to COM and NO inputs of the terminal inside
theReceiverasshown in the"RECEIVERWIRINGDIAGRAM" section.
The directionof thecableends does not matter.
E-Mail:
Invoice Date and Number:
Delivery Time and Place:
Authorised Signatory:
Company Stamp:
product or, in the absence of
a
service station, to the seller, dealer, agency,
representative, importer or manufacturer of the product. Consumer can report the
problem by; phone, fax, e-mail, registered and reply paid letter or a similar way.
However, in case of a conflict, responsibility of prove is belong to the customer. If
the malfunction of the product is not repaired within 20 working days, the
manufacturer-producer or importer; has to allocate another product with similar
featuresto theuse of theconsumer until therepairof theproductis completed,
19-Although the consumer uses his/her repair rights, -If the product breaks down
for 4 times in a yearor 6 times in warranty duration and these problemseffects main
purpose of the product. (Starting from delivery time during warranty.) -Exceeding
the maximum time required for repair, -In the event that the service station is not
available, if it is determined that the repair of the defect is not possible with the
report prepared (in order) by one of the seller, dealer, agency, representative,
importer or manufacturer, a refund or a price discount at the rate of defect can be
requested.
DECLARATION OF CONFORMITY
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş. which Head Office
and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç - Gaziemir -
İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its
specificationsbelow is coveredbytheprovisionsof thementioned directive.
Whatis thedifference?
In non-TPI room thermostats, the heating
/
cooling unit works and stops
continuously until it exceeds the set temperature value. If the set temperature
drops below a certain amount, the heating / cooling unit will work again. This
creates greater temperature fluctuations and less energy control. TPI Room
Thermostats, on the other hand, provide higher savings and comfort compared to
On/Off room thermostatswiththeadvantagesithas.
Brand
: GENERAL Life
ProductName : HT300 RF/HT300S RF
Product
Type: Digital Room Thermostat
Brand: GENERAL Life
ProductType : Digital Room Thermostat
STAMP
Compatible Directives:
Radio and Telecommunications TerminalEquipmentRegulation
2014/53/EU(ETSI EN301489-1 V2.2.3(2019-11),
HeatingMode
Model: HT300 RF/HT300S RF
Your room thermostat takes the average room temperature of last 40 seconds as
basis. With the TPI algorithm in the product by creating a general temperature map
of your home, it learns how long it takes to reach the desired room temperature and
how this temperature is maintained. Thus, it ensures that the room temperature
remainswithin acertain range.
ETSI EN301489-17 V3.2.4(2020-09), EN300220-1V3.1.1,
EN300220-2V3.2.1(2018-06), EN62479:2010, EN62368-1:2014+A11:2017)
Electromagnetic Compatibility Regulation 2014/30/EU
(ETSI EN301489-1 V2.2.3, ETSI EN301489-3 V2.1.1)
Low Voltage Directive2014/35/EU(EN60730-2-9)
20-The customer can make complaints and appeals to consumer courts or
consumer arbitrationcommittees.
21-The warranty document must be kept by the customer during the warranty
period. If the document is lost, a second document will not be issued. In case of
loss, repairand replacementof devicesand apparatus willbe made for afee.
TPI ROOM THERMOSTAT HEATING MODE WORKING GRAPHIC
TEMPERATURE (ºC)
Additional Information: The mentioned product can be used with heating/cooling
units with On-Off output and compliance with the directives only covers the
product. ISIPARK is not responsible for the entire system's compliance with the
directives. This statement is not valid if changes are made to the product without
our approval.
Desired Temperature
TPI Room Thermostat
30
Isıpark reserves the rights of changing product specifications and user
manuals.
23
*For allchanges,youmayvisitgenerallife.com.tr
Time
5
5
6
7
8
| General | Details |
|---|---|
| Name | GENERAL LIFE HT300 RF Digital Room Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.15 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual