GENERAL 260S Wired Room Thermostat User Manual
ROOMTHERMOSTATPLACEMENT
ROOMTHERMOSTATWIRINGDIAGRAM
ENGLISH
Room Thermostat needs to be placed in the room which is used most
frequently. For instance; living room or lounge. Placing the Room
Thermostat in a spot that have air circulation like entrance of a room
or side of window should be avoided. Also anywhere close to
heating/cooling units such as radiator, stove and spots which get
direct sun lights would not be suitable. Room Thermostat needs to be
located above the floor 150 cm height. Few trials may be made to find
themostconvenientspot.
HEATING/COOLING UNIT
DIGITAL ROOM THERMOSTAT
generallife.com.tr
MITRA 260S USER MANUAL
GENERALSPECIFICATIONS
MITRA 260S is a wired room thermostat. The user can adjust the
room temperature with the required temperature and get more
comfortable and economic heating/cooling.
NO COM
min. 20 cm
DIGITAL ROOM THERMOSTAT
Warning!
Operations within the heating
/
cooling unit or the electrical
installationmustbecarriedout byprofessionally qualified persons.
PreciseTemperatureMeasurement
Heatingcalibration
Heating/Cooling Modes
ON/OFFControl
WiredConnection
TPIAlgorithm
ROOMTHERMOSTATTEMPERATURECALIBRATION
Temperature sensors which are used in Room Thermostats are highly
sensitive. You may need to calibrate your Room Thermostat if you
would like to get the same temperature values with other
thermometersinyourliving space.
While your device is turned off, press and hold the button for 3
seconds.
MITRA 260S
USER MANUAL
MITRA260SANDEQUIPMENTS
MITRA 260S
Alkaline
Battery
Dowels and
Screws
Room Thermostat
Press the button until the “
” menu appers. In order to see the
desired temperature, set the temperature difference by turning the
button to right or left. This valuecan be arranged between “-8oC" and
“+8oC".
BATTERY PLACEMENT
Before starting, power off the device connected to the Room
Thermostatand makesurethattheenergy iscutoff.
To save the settings and exit, press the "On/Off" button until the
deviceturnsoff.
TECHNICALDATA
Dimensions
Operating Current
Relay NO Switching Current
85mm / 125mm / 24mm
3V DC (2 x AAA alkaline battery)
2A/30VDC (Resistive load)
0.5A/125VAC (Resistive load)
0.1oC
Note:Recommended tempreturecalibrationis“0.0oC”.
ROOMTHERMOSTATHEATING/COOLINGMODES
Your Room Thermostat has heating and cooling modes. In order to
switcheasilybetweenheating and cooling modes:
While your device is turned off, press and hold the button for 3
seconds.
Temperature Measurement
Accuracy
Operating Temperature Range
Battery Life
Operating Temperature
Storage Temperature
(5oC) – (30oC)
1 Year (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
Pressthebutton until the“
You can switch between “
byturning thebutton torightorleftinthe“
”menu appears.
” (heating) and “
” (cooling) modes
”menu.
To save the settings and exit, press the button until the device turns
off.
ROOMTHERMOSTAT
The settings you have made have been saved. Once you turned on
yourdevice, itwilloperatewiththechanged settings.
1
As shown in the picture above, press the screwdriver forward from the
space shown, bend the tabs and separate the front cover. Insert 2 new
AAA alkaline batteries in the battery housing with the correct battery
direction. Replace both batteries at the same time. Then align the
front part of your Room Thermostat to the back and squeeze it
towards theback.
Low Battery Warning: When the “ ” icon appears on the screen, it
means “low battery warning”. It is recommended to replace the
batterieswhen thiswarning appears.
FACTORY SETTINGS RESET
2
You can reset your Room Thermostat to its default factory settings.
This operation resets the calibration setting and heating/coling
modes to factory setting. To reset your Room Thermostat to factory
setting:
While your device is turned off, press and hold the button for 3
seconds.
3
4
5
6
1
2
3
Battery Indicator
Room Temperature
Set Temperature
Cooling Indicator
Pressthebutton untilthe“
While in the “ “ menu, turn the button to right or left in order to
select“ “option and pressthebutton.
”menu appears.
Warning: When the product is not used for a long period (more than 15
days), remove the batteries. Otherwise, malfunctions that may occur
would beoutofwarranty.
Your devicewillbeturnedoff and resettofactorysettings.
Pleasethrowyourdead batteriesinto thewastebin forbatteries.
- If the Cooling Indicator is blinking, the cooling unit is
4
working.
- If the Cooling Indicator is steady, the cooling unit is not
working.
Heating Indicator
- If the Heating Indicator is blinking, the heating unit is
working.
- If the Heating Indicator is steady, the heating unit is not
working.
5
6
ON/OFF and Temperature Setting Button
generallife.com.tr
2
1
3
General | Details |
---|---|
Name | GENERAL 260S Wired Room Thermostat User Manual |
Make | GENERAL |
Language | English |
Filetype | PDF (Download) |
File size | 1.87 MB |

GENERAL ARUNA 300S Smart Room Thermostat User Manual

GENERAL HT250S Digital Room Thermostat User Manual

GENERAL FH260S Underfloor Heating Thermostat User Manual

GENERAL HT100S Digital Room Thermostat User Manual

GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual

GENERAL HT250 Digital Room Thermostat User Manual

GENERAL SENNA 300 Digital Room Thermostat User Manual

GENERAL ARUNA 300S RF Digital Room Thermostat User Manual

GENERAL SENNA 300 Smart Room Thermostat User Manual

GENERAL MITRA 250S Digital Room Thermostat User Manual

GENERAL 260S Wired Room Thermostat User Manual Overview
Summary of Contents
- Page 1: Room thermostat needs to be placed in the room which is used most frequently. Placing the room thermostat in a spot with air circulation or close to heating/cooling units should be avoided. Room thermostat needs to be located above the floor at a height of 150 cm. MITRA 260S is a wired room thermostat that allows users to adjust room temperature for comfort and economic heating/cooling. Operations within the heating/cooling unit must be carried out by professionally qualified persons. Temperature sensors in room thermostats are highly sensitive and may require calibration for accuracy. To save settings and exit, press the On/Off button until the device turns off. You can reset your room thermostat to its default factory settings, which resets calibration and heating/cooling modes. When the low battery warning icon appears, it is recommended to replace the batteries. If the cooling indicator is blinking, the cooling unit is working; if steady, it is not working.
- Page 2: Warranty conditions state that the warranty period starts from the invoice date and covers manufacturing defects for 5 years. If the placement of the TPI Room Thermostats is changed or if they are de-energized, the learning process will restart and should be considered as 7 days. The TPI algorithm in the Room Thermostat predicts temperature changes and controls the heating/cooling unit to maintain the set temperature with minimal deviations. Devices are delivered in working condition, and on-site commissioning is subject to a service fee. Repairs covered by the warranty are carried out at the company factory, and transportation costs for on-site services are the customer's responsibility. Malfunctions caused by customer misuse or external factors are not covered by the warranty. Customers must report any damages to the manufacturer within the warranty duration to retain their rights. Battery leakage and damages from improper environments are not covered by the warranty. The warranty document must be kept by the customer, and a replacement will not be issued if lost. ISIPARK reserves the right to change product specifications and user manuals.