Home > GENERAL > GENERAL 260S Wired Room Thermostat User Manual

GENERAL 260S Wired Room Thermostat User Manual

ROOMTHERMOSTATPLACEMENT  
ROOMTHERMOSTATWIRINGDIAGRAM  
ENGLISH  
Room Thermostat needs to be placed in the room which is used most  
frequently. For instance; living room or lounge. Placing the Room  
Thermostat in a spot that have air circulation like entrance of a room  
or side of window should be avoided. Also anywhere close to  
heating/cooling units such as radiator, stove and spots which get  
direct sun lights would not be suitable. Room Thermostat needs to be  
located above the floor 150 cm height. Few trials may be made to find  
themostconvenientspot.  
HEATING/COOLING UNIT  
DIGITAL ROOM THERMOSTAT  
generallife.com.tr  
MITRA 260S USER MANUAL  
GENERALSPECIFICATIONS  
MITRA 260S is a wired room thermostat. The user can adjust the  
room temperature with the required temperature and get more  
comfortable and economic heating/cooling.  
NO COM  
min. 20 cm  
DIGITAL ROOM THERMOSTAT  
Warning!  
Operations within the heating  
/
cooling unit or the electrical  
installationmustbecarriedout byprofessionally qualified persons.  
PreciseTemperatureMeasurement  
Heatingcalibration  
Heating/Cooling Modes  
ON/OFFControl  
WiredConnection  
TPIAlgorithm  
ROOMTHERMOSTATTEMPERATURECALIBRATION  
Temperature sensors which are used in Room Thermostats are highly  
sensitive. You may need to calibrate your Room Thermostat if you  
would like to get the same temperature values with other  
thermometersinyourliving space.  
While your device is turned off, press and hold the button for 3  
seconds.  
MITRA 260S  
USER MANUAL  
MITRA260SANDEQUIPMENTS  
MITRA 260S  
Alkaline  
Battery  
Dowels and  
Screws  
Room Thermostat  
Press the button until the “  
” menu appers. In order to see the  
desired temperature, set the temperature difference by turning the  
button to right or left. This valuecan be arranged between “-8oC" and  
“+8oC".  
BATTERY PLACEMENT  
Before starting, power off the device connected to the Room  
Thermostatand makesurethattheenergy iscutoff.  
To save the settings and exit, press the "On/Off" button until the  
deviceturnsoff.  
TECHNICALDATA  
Dimensions  
Operating Current  
Relay NO Switching Current  
85mm / 125mm / 24mm  
3V DC (2 x AAA alkaline battery)  
2A/30VDC (Resistive load)  
0.5A/125VAC (Resistive load)  
0.1oC  
Note:Recommended tempreturecalibrationis0.0oC”.  
ROOMTHERMOSTATHEATING/COOLINGMODES  
Your Room Thermostat has heating and cooling modes. In order to  
switcheasilybetweenheating and cooling modes:  
While your device is turned off, press and hold the button for 3  
seconds.  
Temperature Measurement  
Accuracy  
Operating Temperature Range  
Battery Life  
Operating Temperature  
Storage Temperature  
(5oC) – (30oC)  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
Pressthebutton until the“  
You can switch between “  
byturning thebutton torightorleftinthe“  
menu appears.  
” (heating) and “  
” (cooling) modes  
menu.  
To save the settings and exit, press the button until the device turns  
off.  
ROOMTHERMOSTAT  
The settings you have made have been saved. Once you turned on  
yourdevice, itwilloperatewiththechanged settings.  
1
As shown in the picture above, press the screwdriver forward from the  
space shown, bend the tabs and separate the front cover. Insert 2 new  
AAA alkaline batteries in the battery housing with the correct battery  
direction. Replace both batteries at the same time. Then align the  
front part of your Room Thermostat to the back and squeeze it  
towards theback.  
Low Battery Warning: When the “ ” icon appears on the screen, it  
means “low battery warning”. It is recommended to replace the  
batterieswhen thiswarning appears.  
FACTORY SETTINGS RESET  
2
You can reset your Room Thermostat to its default factory settings.  
This operation resets the calibration setting and heating/coling  
modes to factory setting. To reset your Room Thermostat to factory  
setting:  
While your device is turned off, press and hold the button for 3  
seconds.  
3
4
5
6
1
2
3
Battery Indicator  
Room Temperature  
Set Temperature  
Cooling Indicator  
Pressthebutton untilthe“  
While in the “ “ menu, turn the button to right or left in order to  
select“ “option and pressthebutton.  
menu appears.  
Warning: When the product is not used for a long period (more than 15  
days), remove the batteries. Otherwise, malfunctions that may occur  
would beoutofwarranty.  
Your devicewillbeturnedoff and resettofactorysettings.  
Pleasethrowyourdead batteriesinto thewastebin forbatteries.  
- If the Cooling Indicator is blinking, the cooling unit is  
4
working.  
- If the Cooling Indicator is steady, the cooling unit is not  
working.  
Heating Indicator  
- If the Heating Indicator is blinking, the heating unit is  
working.  
- If the Heating Indicator is steady, the heating unit is not  
working.  
5
6
ON/OFF and Temperature Setting Button  
generallife.com.tr  
2
1
3
GeneralDetails
NameGENERAL 260S Wired Room Thermostat User Manual
MakeGENERAL
LanguageEnglish
FiletypePDF (Download)
File size1.87 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual

GENERAL 260S Wired Room Thermostat User Manual
Get the free PDF manual for the GENERAL 260S Wired Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL 260S Wired Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Room thermostat needs to be placed in the room which is used most frequently. Placing the room thermostat in a spot with air circulation or close to heating/cooling units should be avoided. Room thermostat needs to be located above the floor at a height of 150 cm. MITRA 260S is a wired room thermostat that allows users to adjust room temperature for comfort and economic heating/cooling. Operations within the heating/cooling unit must be carried out by professionally qualified persons. Temperature sensors in room thermostats are highly sensitive and may require calibration for accuracy. To save settings and exit, press the On/Off button until the device turns off. You can reset your room thermostat to its default factory settings, which resets calibration and heating/cooling modes. When the low battery warning icon appears, it is recommended to replace the batteries. If the cooling indicator is blinking, the cooling unit is working; if steady, it is not working.
  • Page 2: Warranty conditions state that the warranty period starts from the invoice date and covers manufacturing defects for 5 years. If the placement of the TPI Room Thermostats is changed or if they are de-energized, the learning process will restart and should be considered as 7 days. The TPI algorithm in the Room Thermostat predicts temperature changes and controls the heating/cooling unit to maintain the set temperature with minimal deviations. Devices are delivered in working condition, and on-site commissioning is subject to a service fee. Repairs covered by the warranty are carried out at the company factory, and transportation costs for on-site services are the customer's responsibility. Malfunctions caused by customer misuse or external factors are not covered by the warranty. Customers must report any damages to the manufacturer within the warranty duration to retain their rights. Battery leakage and damages from improper environments are not covered by the warranty. The warranty document must be kept by the customer, and a replacement will not be issued if lost. ISIPARK reserves the right to change product specifications and user manuals.