Braebur 1230 Non Programmable Thermostat Instruction Manual
INSTALLER SETTINGS
5
The Installer Settings must be properly configured in order for this thermostat to operate correctly. The Installer
Settings are menu driven. The portion of these settings that do not apply to your setup will be skipped.
To Enter Installer Settings Menu
1
Press and hold down the MENU button for 5 seconds.
2 Release the MENU button after the first installer
setting is displayed.
Change settings as required using the or buttons.
3
4 Press MENU to move to the next setting.
5 Menu will exit automatically after last setting.
*If 0000 IL is displayed, you must enter your 4-digit
installer lock code to proceed (see Installer Settings
9 and 10).
No. Installer Setting
Displayed Default Available Description of
Setting Settings Available Settings
F
C
Select for Fahrenheit temperature display
Select for Celsius temperature display
1
2
Temperature Scale
DEG
F
Selects a temperature scale of either °F or °C.
1st Stage Differential DIF1 0.5
0.5, 1.0, 2.0 Select a 1st stage temperature differential of
0.5°, 1° or 2° F (0.2°, 0.5° or 1.0° C)
Selects a 1st stage temperature differential which controls the degree of separation between the setpoint temperature
and the 1st stage of heating or cooling.
3
4
2nd Stage Differential DIF2
2.0
1.0, 2.0, 3.0 Select a 2nd stage temperature differential of
4.0, 5.0, 6.0 1°, 2°, 3°, 4°, 5° or 6° F (0.5°, 1.0°, 1.5°, 2.0°,
2.5° or 3.0° C)
[1230 only] Selects a 2nd stage temperature differential which controls the degree of separation between the 1st
and 2nd stage of heating or cooling.
Compressor Short Cycle CSCP
Protection (CSCP)
5
5, 4, 3,
2, 1, 0
Select CSCP delay duration in minutes
Selects the number of minutes the compressor will be locked out after turning off. This delay will run simultaneously with
any delay built into the equipment.
5
Heat Setpoint
Upper Limit
HIGH HEAT 90
90 - 45
Select a Heat Setpoint Upper Limit of 90° to
(32˚ to 7˚C) 45°F (32° to 7°C)
Selects the upper setpoint adjustment limit that cannot be exceeded in heat mode.
45-90 Select a Heat Setpoint Lower Limit of 45° to
(7˚ to 32˚C) 90°F (7° to 32°C)
Selects the lower setpoint adjustment limit that cannot be exceeded in heat mode.
6
7
Heat Setpoint
Lower Limit
LOWHEAT 45
45 - 90
Select a Cool Setpoint Lower Limit of 45° to
Cool Setpoint
Lower Limit
LOWCOOL 45
(7˚ to 32˚C) 90°F (7° to 32°C)
Selects the lower setpoint adjustment limit that cannot be exceeded in cool mode.