BEOK BOT-R7X Wireless Gas Boiler Heating Thermostat Instruction Manual
2. Install three pieces AA batteries on the transmitting panel.
After turning off the power, press and hold the button
settings
display “——_” to
restore factory settings
for 5 seconds to check the code. When the code checking indicator
light on the receiving panel remains on, the code checking is
successful.
Installation Method
1. Install an expansion screw sleeve with a spacing of 59mm on the
wall.
Programming Mode Operation
In the startup state, press and hold the
enter programming mode. After entering programming mode, press the
button to switch parameters, rotate the outer frame to adjust
various parameters, press the button to adjust for minutes, and
press the button to adjust the temperature. The adjustment
method for the following time periods is the same as the first time
period. Press the button to save and exit.
Key Option
button for 5 seconds to
2. Use a screwdriver to separate the upper cover and the lower cover,
pursuant to the wire direction, pass the wire through the back cover to
the wiring duct, and leave about 20cm long as per the actual situation.
Icon
Time
Adjust Default Adjust
time
Value
20°C
16°C
16°C
16°C
22°C
16°C
22°C
16°C
Temp.
Workday
1
2
3
4
5
6
1
2
06:00
08:00
11:30
12:30
17:00
22:00
08:00
23:00
Rotate
Outer
Rotate
Outer
3. Fix the bottom shell to the wall, and finally fix the wire, and cover the
front shell on the bottom shell.
Frame
Frame
Day Off
Parameter Setting
In the POWER OFF state, long press the
enter the parameter setting interface. At this time, press the
to cycle through the selection of the parameters to be set, rotate the
button for 5 seconds to
Inspection Steps
button
Install the intelligent touch screen thermostat in a place where it is easy
for the user to view the screen and adjust the temperature set point.
The thermostat is located in a place that can represent the overall
ambient temperature of the room. Avoid installing the thermostat near
hot and cold sources, such as vents, heaters, outdoors, etc.
outer frame to adjust the parameters of each item, and press the
button to save and exit.
Parameter
Parameter Name
Default
Value
0
Functional Meaning
Item
1
Temperature
The temperature
Common Faults Handing
compensation
compensation range: -9.9~9.9°C
The temperature difference
start-up range is 0.5~10°C
OFF: Turn off the antifreeze
function
Phenomenon
Solutions
2
3
Switch
setting
The
deviation
1
Don't start up
1. Check whether the battery is installed backwards.
2. Inspect whether the boot key is valid LCD displays.
Whether the rear shell installation is deformed, it can be
loosened and reinstalled.
shutdown
ON
LCD
displays
antifreeze function
starts and stops
messy code
Display is normal,
but there is no
output
ON: Turn on antifreeze function
1. Check whether the boundary between the main control board
and the power board is damaged.
4
Rest day selection
2
0: Turn off programming
1: Take a day off
2. Check whether the output is connected to the wrong wire.
Calibrate the panel temperature display via the first item of
advanced options.
Temperature
displays error
2: Two-day weekend
3: No rest
5
6
Set the upper limit
of the temperature
60°C
—
Set the upper temperature
range from 15~95°C
Restore
factory
Long press
for
3
seconds,
| General | Details |
|---|---|
| Name | BEOK BOT-R7X Wireless Gas Boiler Heating Thermostat Instruction Manual |
| Make | BEOK |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.14 MB |

BEOK Color TFT-LCD Heating Thermostat User Manual

BEOK TDS21WIFI-AC Fan Coil Thermostat Instruction Manual

BEOK TGR85-EP Underfloor Heating Thermostat User Guide

BEOK TDR89 Zigbee Room Thermostat User Guide

BEOK TDS23 Wi-Fi Fan Coil Thermostat Instruction Manual

BEOK TGP53 China Piano Buttons Underfloor Heating Thermostat User Guide

beok TGW60 Thermostat User Guide

BEOK TS4 Series Wi-Fi Touch Screen Thermostat User Manual

BEOK TGP53 Wifi Thermostat User Guide

BEOK TDR89 Glass Screen Thermostat Instruction Manual