Floor temperature limits (AF mode only)
WARNING: To avoid damaging your floor, follow your floor supplier’s recommendations regarding floor tempera-
ture limits.
The minimum and maximum floor temperature limits are 5.0°C (41°F) and 28.0°C (82°F) by default.
To modify these limits, proceed as follows:
n
o
p
q
r
s
t
u
Switch the thermostat to Off.
Press and hold the
button.
Switch the thermostat back to On.
Release the
button when the minimum temperature limit (FL:LO) appears.
Set the minimum temperature limit using the
buttons.
Press the
Set the maximum temperature limit using the
Press Mode/Ret to return the thermostat to normal display.
button to display the maximum temperature limit (FL:HI).
buttons.
NOTE: The thermostat will automatically return to normal display if no button is pressed for 60 seconds.