Home > ATAG > ATAG One Zone Thermostat User Manual

ATAG One Zone Thermostat User Manual

Technical specifications  
Current draw  
Power supply  
BUS (8 to 24V max)  
≤60mA  
Operating temperature  
Storage temperature  
Humidity  
0 to 40°C  
-20 to 70°C  
20% RH to 80% RH  
+/- 0.5°C  
Temperature reading precision  
Bus wire length and cross-sectional area  
NOTE: TO AVOID INTERFERENCE PROBLEMS, USE A SHIELDED CABLE OR  
TWISTED PAIR CABLE.  
max. 50 m  
ø min. 0.6 mm²  
Insulation class  
III  
Protection rating  
Dimensions  
IP 20  
103mm x 103mm x 18.1mm  
2400 MHz - 2483.5 MHz  
+19 dBm - 802.11 b, g, n  
1-13  
Frequency band used  
Maximum power in the band  
Wi-Fi channel  
Product card (with ATAG zone bus system only)  
Supplier name  
ATAG  
Supplier identification model  
ATAG One Zone  
Temperature control class  
V
Energy efficiency contribution (%) for space heating  
With an optional outdoor sensor or internet weather data:  
Temperature control class  
+3%  
VI  
Energy efficiency contribution (%) for space heating +4%  
In a system with 3 zones and at least 2 room controllers:  
Temperature control class  
+4%  
VIII  
Energy efficiency contribution (%) for space heating  
+5%  