PARAMETER  
the actual temp is 1°C lower than set temp and stop to work when the actual temp is 1°C  
higher than set temp.  
No.  
Name  
Ranges  
Default  
OFF  
11  
Adap�ve Func�on  
ON/OFF  
ON/OFF  
7.Temp unit: °F and °C can be selected.  
12  
Open Window  
OFF  
8:Sensor selec�on  
13  
0W -- 4500W  
Power Set  
0 W  
Room sensor: Run by room sensor.  
14  
Floor sensor: Run by floor sensor.  
Energy Use  
Both sensors: Run by room sensor with floor temp limit.  
9. Schedule: Select a weekly schedule for the event.  
0-3950  
1-3380  
2-3700  
3-3600  
4-3740  
15  
Sensor Type  
0-3950  
7: each day from Mon to Sun can be set individually.  
5+1+1: Mon to Fri have the same events, Sat and Sun can be set individually.  
10. Output delay: This op�on help you avoid inadvertent opera�on on hea�ng.  
11. Adap�ve func�on: Aer several days of installa�on and use, Adap�ve func�on  
ensures that the required temp has already been reached when the next event begins.  
12. Open window: This func�on only works when room sensor or both sensors is selected.  
The thermostat with this func�on will shut off automa�cally for 15 min when the window  
opens, as it can detect that the room temp plummets.  
16  
Factory Reset  
NO  
NO/YES  
1. Room Temperature calibra�on: Calibrate the temperature detected by room sensor.  
2. Floor Temperature calibra�on: Calibrate the temperature detected by floor sensor.  
3&4. An�-frozen func�on: If the An�-frozen func�on opened, it will keep the room  
and floor at a lower temperature in order to protect the pets and plants in your house.  
Also, it can protect your pipe against freezing when using the water hea�ng system.  
5. Floor temperature limit: When choose both sensors, you can set the maximum  
floor temperature value, system will stop hea�ng if the floor temperature exceed this  
value.  
13&14. Energy use: This op�on allows you to enter the various data used to calculate  
energy use.  
15.Sensor Type: This thermostat is compa�ble with the following five floor temperature  
sensors. The default sensor 0-3950 is in the box.  
6. Temperature Tolerance: The value is 1°C. The thermostat start to work when  
11  
12  
PARAMETER  
GeneralDetails
NameAJAX ETHT82 White Touch Screen Thermostat Instruction Manual
Makeajax
LanguageEnglish
FiletypePDF (Download)
File size0.36 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
AJAX108845 White Digital Programmable Thermostat User Guide
AJAX108845 White Digital Programmable Thermostat User Guide
AJAX108846 White Smart Wifi Thermostat Instruction Manual
AJAX108846 White Smart Wifi Thermostat Instruction Manual

AJAX ETHT82 White Touch Screen Thermostat Instruction Manual