AFRISO RT 10 D 230 Room Thermostat Instruction Manual
USE OF THE ROOM THERMOSTAT RT 10
NTC SENSOR FUNCTION DESCRIPTION (ONLY WORKS WHEN SEN PARAMETER = 02)
When the temperature measured by the additional (external) NTC sensor exceeds the temperature set in the OSV parameter,
the thermostat will switch off the control output (stop heating), even if the set temperature has not been reached in the
heating zone. This function is intended to protect the floor in an underfloor heating system from overheating, which can lead
to permanent damage to the floor.
Setting date and time: To set the time and the date, press the key
, and then set the displayed time with the key
and
.
Press the key
once to set the hours. Press the key a second time to set the minute and a third time to set the day of the week.
Locking the keys: To activate the keyboard lock, hold down the key
pressing the key for 5 seconds.
for 5 seconds. The keyboard lock is deactivated by
SENSOR FAILURE
Manual mode: Press the key M. Set the temperature with the keys and . The mode remains on until the M key is pressed
again. Manual mode is indicated by the symbol being displayed.
You must correctly select the internal or external temperature sensor against which the thermostat will operate. If the selection
is wrong or the sensor is faulty, the display will show Er. The thermostat will not operate until the fault is corrected.
Week mode: Hold down the key M. When "Loop" is displayed, set the days of the week with
the temperature with the keys or . Press the key . Set the time with the keys or
switch between the days and the temperatures.
or
. Press the key M. Set
ANTI-FREEZE FUNCTION DESCRIPTION
. If you press the key M, you
The anti-freeze function works independently of schedules and thermostat settings, sending a heating signal when a tempe-
rature drop below 5°C is detected. Once the temperature exceeds 7°C, the thermostat stops transmitting the heating signal.
Within the schedule, the week can be divided into: 5, 6 or 7 working days. The following time intervals can be configured for
workdays and days off:
TECHNICAL SPECIFICATIONS
Time intervals for working days
General parameters
Value
Icon
Starting time
Default setting
Dimensions (H x B x T)
Mounting holes spacing
Weight
86 x 86 x 40 mm
60 mm
6:00
20°C
163 g
8:00
11:30
12:30
17:30
22:00
15°C
15°C
15°C
22°C
15°C
Ambient temperature
Measuring range
5÷60°C
5÷99°C
NTC
Type of the external sensor
Electrical parameters
Value
Supply voltage
230 V AC
Power consumption
Pollution degree
< 0,3 W
II
Time intervals for days off
Rated impulse voltage
Protection class (EN 60730)
Degree of protection (EN 60529)
Contact rating
2500 V
8:00
22°C
15°C
II
IP20
23:00
Maximum 3 A 250 V AC
INDICATION
APPROVALS AND CERTIFICATES
Heating active icon
Manual mode
AFRISO GmbH hereby declares that the product complies with:
•
•
•
Low Voltage DIrective 2014/35/UE,
EMC Directive 2014/30/UE,
RoHS II Directive 2011/65/UE.
Anti-freeze function icon
Key lock icon
DECOMMISSIONING, DISPOSAL
Time interval icon
1. Disconnect the product from the power supply.
Temperature
on the internal sensor
2. Dismount the product.
3. In the interest of environmental protection, the decommissioned appliance must not be disposed of with
unsorted household waste. Return the product to the appropriate collecting point or to the manufacturer’s
or distributor’s collecting point.
Set temperature
Temperature on the external sensor
(in case of using external sensor)
Day of the week
(1 - Mon. ... 7 - Sun.)
Clock/function menu
On/Off button
WARRANTY
Product guarantee in accordance with the general conditions of sale and delivery.
Decrease of the setting
RETURNING THE DEVICE
Get in touch with us before returning your product (service@afriso.de).
ADDRESSES
Menu button
Time button
Increase of the setting
3
4
| General | Details |
|---|---|
| Name | AFRISO RT 10 D 230 Room Thermostat Instruction Manual |
| Make | AFRISO |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.12 MB |