TR33 Large LCD Screen Smart Thermostat Instruction Manual
Large LCD screen smart thermostat
√Customized exclusive temperature plan - up to 6 events allowed
to set per day
Sail shape design-delicate and elegant
√
√
√
Large LCD screen-better user experience
485 modbus and room card linkage - customized equipment (optional)
Parameter
Supply voltage
AC100~240V; 50/60Hz
1W Max (Wi-Fi 3W Max)
5~95℃(41~99℉)
20~90℃(68~99℉)
0.5~10℃(1~10℉), Factory setting ±1℃
-5~50℃(23~99℉)
IP20
Power consumption
Temp. setting range
Floor limited range
Temp. Dif.
Ambient temperature
Protection level
Shell material
Anti-Flammable PC
Version:TR33 1.6(12/2023)
Product Overview
This series of thermostat has Floor Heating, Fan Coil, and Integrated version, meeting the
requirements under different scenarios.
ated)
Integr
ating/
or He
g (Flo
Settin
mode
Auto-
setting.
auto-mode
to edit
“
” for
3 seconds
Press
e
eratur
Temp
Time
ols
Symb
s
Event
Version
System mode
Model
Application
e
lt valu
Defau
e
Mod
ify
Modi
fy
lt valu
Defau
Built-in & floor sensor, floor limit sensor +
Weekly programming
EP
)
)
)
(68℉
(59℉
(59℉
20℃
15℃
15℃
06:00
1
2
3
Floor
heating
Press
Pr
ess
Floor heating
ANC/NO dual-output + Weekly programming
WP
08:00
11:30
ANC/NO dual-output + Weekly programming+
Potential-free output
Timer task + 2-pipe system
Timer task + 2-pipe system + 485Modbus (optional) +
Potential-free output + Room card (optional)
”
“
”
“
WPB
AC2
ays
Workd
)
)
)
(59℉
(72℉
(59℉
15℃
22℃
15℃
12:30
17:00
22:00
4
5
6
or
or
Heating /Cooling /
Ventilation
Fan Coil
AC2-485
AC4
”
“
”
“
Timer task + 4-pipe system + 485Modbus (optional) +
Potential-free output + Room card (optional)
)
(68℉
20℃
06:00
20:00
1
2
ends
Week
)
(68℉
20℃
Heating / Cooling /
Floor heating & fan coil, weekly programming +
Potential-free output + Timer task +
485Modbus (optional) + Room card (optional)
Integrated Ventilation/Floor heating /
Floor heating + Heating
AWY
Advanced Setting (Usually for Professional Technicians)
Under power-off, press “ ” for 3 seconds to enter advanced setting mode, then re-press
“
” to switch to next mode. Press “ ” to save and exit advanced setting mode.
Display Symbols
Floor
Heating
Integrated
AWY
FanCoil
Default
Value
Meaning
Postal address(optional) Adjustment range 0x00~0xFA
Setting temp.
Time Display
Code
“
”or“
”
AC2-
AC4 AC2 EP WP WPB
485
Week Display
Wi-Fi
00
01
02
√
√
√
√ √
√ √ √
00
×
Wake up; Event 1
Leave (am); Event 2
Return (am); Event 3
Leave (pm); Event 4
Return (pm); Event 5
Sleep; Event 6
Timer Task
Temp. calibration
Temp. Dif.
-9.9~9.9℃(-9~9℉)
√ √ √ √ √ √
-3℃
±1℃
Manual Mode
Auto Mode
Temporary Mode
0.5~10℃(1~10℉)
√
√
√
√ √ √
√ √ √
√ √ √
√ √
√ √
√ √
Temp. upper limit
Temp. lower limit
03
04
5~95℃(41~99℉)
√
√
50℃
5℃
ECO
ECO Mode
Fan Speed Display
Room Temp.
Floor Temp.
5~47℃(41~99℉)
Child-lock
Frost Protection
Room Temp.
ON: frost protection on
OFF: frost protection off
Frost protection
Temperature unit
05
06
OFF
√
√
√
√
√ √ √
√ √ √
√ √
√ √
Cooling on
Heating on
Fan-Coil Ventilation Mode
Fan-Coil Cooling Mode
Floor Heating Mode
℃/℉
℃
Fan-Coil Heating Mode
IN:Controlledbybuilt-insensor
OUT:Limitedbyfloorsensor
ALL:Controlledbybuilt-insensorand
limitedbyfloorsensor
Fan(Integrated)
Power on/off
Mode
Sensor selection
07
IN
√
×
√ √ √
√ √ √
× ×
× ×
ECO(Floor heating)
Down
Up
Floor limited Value
08
09
20~90℃(68~99℉)
√
√
×
×
35℃
12345: 5/2 week mode
123456: 6/1 week mode
1234567: 7/0 week mode
Weeklyprogramming
setting
Temperature Control Mode(Floor Heating/Integrated)
12345
× × √ √ √
Manual Mode
Thermostat works based on manually-set temperature, disconnecting from auto mode.
00: Fan speed controllable
01: Fan speed uncontrollable
Fan control settings
Delaytimeofoutputs
10
11
00
√
√
√ √ √ × × ×
× × × √ √ √
Auto Mode
Weekly-circled programme, up to 6 heating events can be set per day. Heating events,
workdays and temperature can be separately customized based on personal routines.
0~5min
0
00: Child-lock inactivate when screen off;
lock all when child-lock activate
01: Child-lock activate when screen off;
lock all when child-lock activate
02: Child-lock activate when screen off;
lock all except Fan Speed, Up and
Down when child-lock activate
Temporary Mode
Thermostat works based on manually-set temperature temporarily and then shifts
back to auto mode till next event.
User Operation
Power on/off : Press “ ” shortly to turn on/off the thermostat.
Auto-mode :
Child-lock
12
00
√
√
√ √ √
√ √
03: Child-lock activate when screen off;
lock all except Power on/off when
child-lock activate
Press “ ” for 3 seconds to edit auto-mode settings.(Floor Heating/Integrated)
Press “ ” for 3 seconds to edit timer task. (Integrated)
Timer task:
Time setting:
Press “ ” for 3 seconds to set time.(Floor Heating)
00: Power OFF
01: Power ON
02:The last status before power loss
Boot Status
13
14
02
00
√
√
√ √ √ √ √ √
√ × × × × ×
Press “ ” twice for 3 seconds to set time.(Automatic time synch for Wi-Fi version)
Press “ ” or “ ” shortly to change setting temperature by 0.5°C.
Temp setting:
Child-lock:
System mode:
00:turnoffroomcardfunction
01:settoECOtemp. afterpullingroom
cardout
02:staypower-offafterpullingroom
cardout
Press “ ” + “ ” for 3 seconds to activate child-lock.
Press “ ” shortly to switch cooling/heating/ventilation(Fan Coil/Integrated)
Room card status
Press “ ” shortly to switch cooling/heating/ventilation/floor heating/floor
heating + heating.(Integrated)
Room card heating
ECO temp.
15
16
17
10~21℃(50-69℉)
√
√
√
√ × × × × ×
√ × × × × ×
√ √ √ × × ×
18℃
26℃
00
Room card cooling
ECO temp.
Temp control mode: Press “ ” shortly to switch manual/auto mode.(Floor heating)
Press “ ” shortly to switch manual/auto mode.(Integrated, floor heating)
22~32℃(72-89℉)
00: Cooling and heating
01: Cooling only
Fancoilmodesetting
Fan speed setting:
ECO mode:
Press “ ” shortly to adjust fan speed.(Integrated)
Weeklyprogramming 00: turn on
Press“ ”shortly to set to ECO mode 18°C(65°F). (Floor heating)
18
19
01
/
√
√
×
√
× × ×
√ √ √
× ×
√ √
01: turn off
forIntegrated
Reset
Press “ ”for 3 seconds to reset
| General | Details |
|---|---|
| Name | TR33 Large LCD Screen Smart Thermostat Instruction Manual |
| Make | Thermostat |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.05 MB |

STN855W WiFi Digital Programmable Thermostat Instruction Manual

Digital Touch Thermostat Troubleshooting User Guide

TR33 Large LCD Screen Smart Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: Large LCD screen smart thermostat Customized exclusive temperature plan - up to 6 events allowed to set per day Sail shape design - delicate and elegant Large LCD screen - better user experience This series of thermostat has Floor Heating, Fan Coil, and Integrated version, meeting the requirements under different scenarios. Weekly programming allows for customized heating events based on personal routines. Manual mode disconnects from auto mode and allows for manually-set temperature. Auto mode features a weekly-circled program with customizable heating events. Temporary mode allows for manually-set temperature temporarily before reverting to auto mode. User operation includes power on/off and editing auto-mode settings.
- Page 2: Large LCD screen smart thermostat The thermostat operates in full capacity in areas with the altitude of less than 2500 meters above sea level. Power rating of external load should be less than or equal to 80% rated power of the thermostat in areas with altitude of 2500m to 4200m. Er0: built-in error is displayed when the sensor is disconnected or short-circuited. Er1: floor sensor failure. Press “ ” for 3 seconds to enter timer task setting; press “ ” to change settings. The thermostat adopts a pre-guide and limited snap-fit design. It is easy to mount. Suggested wire-stripping length is 7-9mm. Make sure that the thermostat is fixed without deformation. Suggested torque is 0.2~0.4N.m (2.0~4.1kgf.cm). Re-mount the front cover via snap-fit connection.
- Page 3: Page 3
- Page 4: Device sharing App control interface Fan coil & floor heating Slide to adjust temperature Fan