V. HOW TO USE THE CONTROLLER  
1.  
PRINCIPLE OF OPERATION  
The main task of ST-295 is to maintain the pre-set room/floor temperature by sending a signal to the heating device  
(contact closing) or to the external controller managing the actuators, when the room/floor temperature is too low. When  
such a signal is received, the heating device opens the flow in the thermostatic valve.  
2.  
OPERATION MODES  
The regulator may operate in one of the two operation modes available:  
Day/night mode in this mode the pre-set temperature changes depending on the time of the day. The user  
presets the temperature values for both day-time and night-time as well as the time of entering day mode and  
night mode. In order to activate this mode, press EXIT and hold until a corresponding icon (day/night mode)  
appears on the main screen.  
Manual mode In this mode, the user sets the temperature in the main screen view using PLUS and MINUS  
buttons. The manual mode will be activated automatically after pressing one of these buttons. Once this mode  
is activated, the previously selected mode enters ‘sleep mode’ and remains inactive until the next pre-  
programmed temperature change. The manual mode may be deactivated by pressing EXIT button.  
VI. MAIN SCREEN DESCRIPTION  
The user navigates in the menu structure using buttons.  
1
2
5
3
4
7
       
GeneralDetails
NameTECH EU-295 Underfloor Heating Room Thermostat User Manual
MakeTECH
LanguageEnglish
FiletypePDF (Download)
File size0.59 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

TECH EU-295 Underfloor Heating Room Thermostat User Manual