From A1 to AE, short press to choose the option, and adjust data by or , short press
switch next option.Remain about 5 seconds after finish setting will quit setting.
to
NO
Setting Options
Data Setting Function
Factory Default
N1:Internal sensor (high temperature protection
close)
N2:External sensor (high temperature protection
close)
N3:Internal sensor control temperature ,external
sensor limit temperature (external sensor detect
the temperature is higher than highest
temperature ofexternal sensor, thermostat will
Close relay,turn off load)
NO
Setting Options
Measure Temperature
Calibration
Data Setting Function
-9-+9℃(Displayed as the corrected room
temperature value)
Factory Default
A1
-1
Options of sensor
control
Start/stop working
temperature difference
setting
Children lock setting
Power on/off state
BN
N1
A2
A3
0.5-2.5℃
1℃
0:half lock 1:full lock
0:Thermostat on/off with memory whenel
0
0
memory after electricity ectrify
0: Disable descaling function
Descaling
function
A4
BC
Bo
cut
1:Thermostat off when electrify
0
1: Enable descaling function
2:Thermostat on when electrify
product
Can’t be changed
A5
A6
Standby bright
0: Off 1: Weakly bright 2: Brighter
2
0
0: 5+2
1: 6+1
2: 7
information
Weekly programming
selection
Return difference: limit valve of external sensor is 45℃ for factory default (A6),value of external
sensor control return difference (A3) is 2. when temperature rise to 45℃,then relay stop working and will
remind high temperature production alarm. If temperature decline to 43℃relay continue to work and
heating alarm will be relieved, (it can be operated ,only when room temperature is lower than setting
temperature ).
Setting temperature
minimum limit
Setting temperature
maximum limit
A7
A8
1-10°C
5°C
20-70°C
35°C
1-10°C
Sensor fault display:please choose correct working way of built-in and external sensor, if choose
wrongly or sensor fault (breakdown), “E1” or “E2” will be displayed on the screen. Thermostat will stop
heatinguntil the fault is eliminated
Warranty:
We offer the warranty of 24 months, from the sales day. The products of our company can have
Low temperature
protection
A9
AA
AB
AC
When setting temp = 10℃, if press
display【--】, cancel low temperature protection
will
5°C
High temperature
protection for external
sensor
High temperature
protection temperature
difference setting
Window function
triggers temperature
20°C-70°C
When setting temp =20℃, , if press
display【--】, cancel high temperature protection
will 45°C
lifetimewarranty ,if it is not the quality problems, or beyond the warranty period, we will charge for the
after-saleservice.
1-9°C
2°C
Installation
5-25°C
--
When setting temp =5℃, if press
will
display【--】, cancel high window function
Window function
running time
Restore factory defaults
(Advanced Option A)
Heating/Cooling mode
AD
AE
AF
5-60min
10
0
Display Ao , long press
show
0: heating
key to whole icon
1: cooling
Advanced option B
Power off state, long press for 3-5 seconds to access advanced option B.
short press to choose the option, and adjust data by or , short press
option.Remain about 5 seconds after finish setting will quit setting.
to switch next
| General | Details |
|---|---|
| Name | Smartica HY608W 3A Wifi Digital Heating Thermostat User Manual |
| Make | Smartica |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.22 MB |

Smartica HY607B 3A Zig Bee Thermostat User Manual