ROLBIT C124W Under Floor Thermostat Instructions
Under Floor Thermostat
C124W
Thermostat
HEATER
N
IN
L~
IN
1
N
OUT
2
N
IN
3
4
L~
IN
5
L~
OUT
PE
C124
85.6
6
7
8
9
LIMIT
TEMP.
SENSOR
ROOM
TEMP.
SENSOR
INSTALLATION
•
The C124W thermostat is produced in few part numbers to match the application needed.
Please check the below part number and match with the unit in your hand to be sure it is the type you need
for your application.
•
INSTALLATION REQUIRMENT
All wiring must be made according to the local electrical codes.
MOST POPULAR ITEMS
•
•
C124W-RLS-A-2429-16 - Set Point Range 5 / 30°C, Limit sensor 29°C Off – 24 On with 0.5 amps load.
Supplied with one external sensor.
Note: If the Limiting sensor should be used, order additional sensor Part number 3SE1030010100.
C124W-UFS- Set Point Range 5-50°C with 0.5 amps load.
OPTIONS
Set Point Range – (Working Temp. Range)
•
•
•
A - 5 / 30°C Scale.
B - 5 / 40°C Scale.
C - 5 / 50°C Scale.
LIMITS – UNDER FLOOR TEMPERATURE CUT-OUT
•
•
•
2429 - Limiting Range at 29°C Off at 24°C On.
3040 - Limiting Range at 40°C Off at 30°C On.
4050 - Limiting Range at 50°C Off at 40°C On.
OPERATION VOLTAGE
•
Standard - 230 VAC 50-60 HZ.
Optional - 120 VAC 50-60 HZ.
•
RESISTIVE LOAD
•
Standard - 0.5 Amps.
EXTERNAL SENSOR
•
Standard - 3 meters cable. Part number 3SE1030010100
Optional - 6 meters cable. Part number 3SE1060010100
•
NOTE: Thermostats with limiting sensor to protect the under floor heating. In case this feature is not needed, do not
remove the resistor at the ext. sensor terminals.
26 Hashoham St. Barkan industrial Zone , Israel,4482000
T e l : 9 7 2
3
9 0 6 7 9 6 1
F a x : 9 7 2
3
9 0 6 0 0 3 4