qunda QD-HVAC15 WIFI Touch-Screen Programmable Thermostat Instruction Manual
(1)
Meanwhile the room temperature, clock will be also displayed. Change to the heat mode by the
second pressing and “ ” is displayed. Press again to turn off the system.
: press the “
” key once to turn on the system. The mode is cool and “
” is displayed.
Everday
(2) Setting temperature: when power on, press “ ” or “ ” to set the temperature. Press
“
” to lower the setting temperature, and press “ ” to raise the setting temperature.
(3)
: When power on, press it to choose the fan on, and press again to change the fan
to auto mode.
(4) M : When power on, press the key to run the program what has been set. Meanwhile “ Run ”
is displayed. In the programming mode or changing the system parameter, press “ M ” to exit
and save the changed parameter.
When power off, hold “
” key for 5 seconds to enter the parameter changing interface.
(5)
: When power on, press the hold key to keep the setting temperature. It won't run the
Room temperature area displays each symbol of the parameter, and system clock area displays
each parameter of the parameter values.Repeat to press “ ” key to cycling display the each
program and display hold. For example: now the setting temperature is 60℉,after pressing
the key, the system will lock the setting temperature to be 60℉.
parameter. Press “ ” or “ ” to adjust each parameter. After finished changing, press “ M ”key
to exit the setting interface and save the set parameter.
(if there's no any operation within 30 seconds when setting, the system will exit the setting interface
and abandon the changed parameter.)
Display(Factory
Defaults)
ꢀꢀꢀDefault
or
Press
Press
Buttons
Step
01
Description
parameters
to select
When power on(in cool/heat mode),hold “
” for 3 seconds to enter the programming mode:
Select fast cooling or
slow cooling
5
CC
FA or SL
FA
seconds
(1) First is to set the system clock. When the clock area is flashing, press “ ” or “ ” to change
the clock. And if you hold “ ” or “ ” , the adjustment will be faster.
Select fast heating or
slow heating
HC
FC
CP
CA
FA or SL
F or C
FA
C
5
02
03
04
05
Select ℉ or ℃ Readout
(2) Press “
the week.
” again to set the week. When the week flashing, press “ ” or “ ” to change
Compressor Lockout delay time
0 = none ; 5 = Minutes
0 or 5
room temperature error correction
-5° to + 5°
0
(3) Press “
” again to set the Wake time
for Monday. When the clock area is flashing,
conventional heat pump selection
0: conventional mode
1: heat pump mode
Select cool/heat change over valve
"b" = heat change over valve
"O" =cool change over valve
press “ ” or “ ” to adjust the time.
06
07
HP
Ob
1 or 0
O or b
0
(4) Press “
” again to set the Wake temperature for Monday When the room temperature area is
O
flashing, press “ ” or “
”t o adjust the temperature.
”, then you can set the time and temperature of Leave
Intelligent Recovery Option
"1" = Active "0" =Deactivated
(5) Repeat pressing the “
, Return
,
08
09
10
IC
6E
bS
1 or 0
E or 6
S or b
0
E
b
Sleep
, from Monday to Friday and Saturday, Sunday by turn.
"E"=Electric "6"=Gas
S:backlight always be on
b:backlight will get dark
(6) After finished the setting, press the “ M ” to cancel the setting interface and save the parameter.
(if there's no any operation within 30 seconds when setting, the system will exit the setting interface and
abandon the changed parameter.)