LENNOX L40 Smart Thermostat Owner’s Manual
NOTES
1. See Air Handler Unit Installation
Instructions for the Lennox L40
Thermostat wiring.
Single Stage Furnace and Single Stage Air Conditioner
Single Stage Air Handler and Single Stage Air Conditioner
2. Optional normally closed (NC)
Condensate Float Switch
L40 Smart Thermostat
L40 Smart Thermostat
3. Thermostat / Outdoor Unit Terminal
Block (BLACK)
4. Indoor Unit Terminal Block (BLUE)
W
C
W
C
W1
W2
W
5. When wired with heat pump
applications, a Defrost Tempering Kit
(67M41) must be installed.
G
O/B
R
G
6. ACC2 terminal is set at the factory for
R
R
G
Y
dehumidifier.
Black
C
O
R
7. Cut on-board clippable link from R to O
G
for heat pump applications only.
Yellow
Y1
8. Install field-provided jumper between Y2
OUT BL on heat pump to Y2 on indoor
unit.
Y
DS
9. Defrost Temper Kit (67M41).
O/B
Black
C
10. Condensate Overflow Switch
C
Y
C
Typical Single Stage
Furnace
Lennox Typical Non- Low GWP
Y1
Yellow
Y1
Y2
Single Stage Air Condiꢀoning Unit
Lennox Typical Non- Low GWP
Single Stage Air Condiꢀoning Unit
Typical Single Stage
AHU
Single Stage Air Handler and Single Stage Heat Pump
Single Stage Furnace and Single Stage Dual Fuel Heat Pump
Single Stage Furnace and Single Stage Air Conditioner with
Refrigerant Detection System (RDS)
2
OPTIONAL
L40 Smart Thermostat
N.C. CONDENSATE
FLOAT WITCH
L40 Smart Thermostat
RDS Sensor
W1
W2
W1
W
L40 Smart Thermostat
4
3
SW2 SENSOR #1 SENSOR #2
W1
W
C
W
W1
W2
G
W
G
W1
W2
G
W
G
O/B
R
G
C
R
G
Y
C
R
ON
O
R
O
R
G
LED
SW1
O/B
O/B
R
R
G
Y
O/B
R
R
R
DS
DS
C
DS
C
RDS Field Kit – 24 Volt
Cat # (27A02)
C
Y
C
C
C
Y
C
Y
Y1
Y1
Y2
Y1
Y2
Y1
Y1
Y2
O/B
O
TSTAT
INDOOR
Typical Single Stage
Furnace
Lennox Typical Non- Low GWP
Single Stage Heat Pump Unit
Typical Single Stage
Furnace
ZONING
NO COM NC
ALARM
NO COM NC
Typical Single Stage
AHU
1
Lennox Typical Non- Low GWP
Single Stage Heat Pump Unit
Black
C
Yellow
Y1
Lennox Typical Non- Low GWP
Single Stage Air Condiꢀoning Unit
| General | Details |
|---|---|
| Name | LENNOX L40 Smart Thermostat Owner’s Manual |
| Make | Lennox |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.17 MB |

LENNOX EL18KCV Smart Wi-Fi Communicating Thermostat User Manual

LENNOX S40 Smart Thermostat User Guide

LENNOX L40 Smart Thermostat Owner’s Manual Overview
Summary of Contents
- Page 1: See air handler unit installation instructions for the Lennox L40 thermostat wiring. When wired with heat pump applications, a defrost tempering kit must be installed. ACC2 terminal is set at the factory for dehumidifier. Install field-provided jumper between Y2 OUT BL on heat pump to Y2 on indoor unit. Cut on-board clippable link from R to O for heat pump applications only. Condensate overflow switch is included. Typical single stage furnace and single stage air conditioning unit configurations are provided. L40 smart thermostat options are available. Optional normally closed condensate float switch can be used. RDS sensor is part of the system setup.
- Page 2: Single stage air handler or single stage heat pump with refrigerant detection system (RDS) Single stage furnace or single stage heat pump (dual fuel) with refrigerant detection system (RDS) Optional N.C. condensate float switch RDS sensor L40 smart thermostat RDS field kit – 24 volt Defrost tempering kit Typical single stage AHU Typical single stage furnace Lennox typical non-low GWP single stage heat pump unit