Advanced settings
• Switch on the thermostat. Press and hold the button
release to access the advanced settings mode.
for 3 seconds and then
• Press
to switch between the menu items.
02822/537 64 01
Nr.
1
Display
Setting Option
Data setting
Function
Factory
default setting
A1
A2
A3
A4
A5
Open window detection
5–25°C, 5–60 min
Deactivated (-- °C)
2
Temperature difference for
Activation of the heating element
1–9°C
20–70°C
1–10°C
± 5°C
2°C
35°C
5°C
3
Temperature setting –
Maximum value
4
Temperature setting –
minimum value
5
Temperature sensor calibration
(adjustment may be necessary
depending on the position of the
thermostat)
0,5°C
Factory calibration
6
7
A6
A7
Frost protection
00: Freeze protection function OFF
01: Freeze protection function ON
00: Freeze protection
function OFF
Resumption of operation after
power interruption
1: Resumes operation after power
interruption
1: Resumption of
operation after
0: Remains switched off after dis-
connection from the power supply
power interruption
8
9
A8
A9
AA
Operating mode
01: Heating mode
01: Heating mode
00: Programmable
N/A
Programmable or not
programmable
00: Programmable
01: Not programmable
10
Back to factory setting
88: Not to factory setting reset
00: Back to factory setting
8