Honeywell TH5220D Non-Programmable Digital Thermostat Installation Guide
FocusPRO™ TH5220D Non-programmable Digital Thermostat
In case of difficulty
Heating equip-
ment is running
in cool mode
•
Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed heating/cooling equipment (see page 11).
Cannot change
system setting
to “Heat”
•
•
Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed heating equipment (see page 11).
Change Installer Setup, Function 12 (System Setting) to Manual or Auto
Changeover (see page 12).
Cannot change
system setting
to “Cool”
•
•
Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed cooling equipment (see page 11).
Change Installer Setup, Function 12 (System Setting) to Manual or Auto
Changeover (see page 12).
“Heat On” is
not displayed
•
•
•
Change the System Setting to Heat, and set the temperature level above
the current room temperature.
“Cool On” is not
displayed
Change the System Setting to Cool, and set the temperature level below
the current room temperature.
“Cool On” or
“Heat On”
is flashing
Compressor protection timeout is engaged. Wait 5 minutes for the
system to restart safely, without damage to the compressor.
Accessories & replacement parts
Please contact your distributor to order replacement parts.
Battery holder ......................................................Part Number 50007072-001
Cover plate assembly ........................................Part Number 50002883-001
(Use to cover marks left by old thermostats.)
Specifications
Temperature Ranges
Electrical Ratings
•
•
Heat: 40° to 90°F (4.5° to 32°C)
Cool: 50° to 99°F (10° to 37°C)
Terminal
Voltage (50/60Hz) Running Current
W (O/B) Heating
(Powerpile)
20-30 Vac
750 mV DC
20-30 Vac
20-30 Vac
20-30 Vac
20-30 Vac
20-30 Vac
20-30 Vac
0.02-1.0 A
100 mA DC
0.02-0.5 A
0.02-1.0 A
0.02-1.0 A
0.02-0.5 A
0.02-1.0 A
0.02-0.5 A
Operating Ambient Temperature
32° to 120°F (0° to 48.9°C)
•
W2 (Aux) Heating
Y Cooling
Shipping Temperature
-20° to 120°F (-28.9° to 48.9°C)
•
Y2 Cooling
Operating Relative Humidity
5% to 90% (non-condensing)
•
G Fan
E Emergency heat
L Heat pump reset
Physical Dimensions
•
•
3-9/16” H x 5-13/16” W x 1-1/2” D
91 mm H x 147 mm W x 38 mm D
17
firealarmresources.com
| General | Details |
|---|---|
| Name | Honeywell TH5220D Non-Programmable Digital Thermostat Installation Guide |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.58 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell D1-528 Direct Thermostat Installation Guide

Honeywell FocusPRO P200 Programmable Thermostat User Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide