Honeywell T827 Series Heat Only Vertical Thermostat Owner’s Manual
English: Page 1 • Français : Page 6 • Español: Página 11
Base installation
1. Pull wires through wire hole.
Position base on wall, level
and mark hole positions.
2. Drill holes (3/16” holes for
drywall, 7/32” holes for plas-
ter), then tap in supplied wall
anchors.
3. Pull wires through base, posi-
tion over anchors, and insert
screws. Check level if desired,
then tighten screws.
M27305
Wiring
1. Loosen screw terminals, insert bare wires
beneath screws, then re-tighten screws.
2. Push any excess wire back into the wall
opening
3. Plug the wall opening with nonflammable
insulation to prevent drafts from affecting
thermostat operation.
Terminal Designations
R
R power. Connect to 24 V hot on secondary
side of heating/cooling transformer or R on
furnace/boiler for 750 mV systems.
W1 Heat relay.
Y2 Cool relay, or
normally open hot water valve.
G
1
Fan relay (select models only)
T822K and T827K
T822L
2
Wire specifications
Use 18-gauge thermostat wire. Shielded
cable is not required.
M27306
3
69-2251EFS—05
| General | Details |
|---|---|
| Name | Honeywell T827 Series Heat Only Vertical Thermostat Owner’s Manual |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.52 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell D1-528 Direct Thermostat Installation Guide

Honeywell FocusPRO P200 Programmable Thermostat User Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide