Honeywell PRO 1000 Series Heat Pump Thermostat Instruction Manual
PRO 1000 Series
In case of difficulty
Screen is blank.
•
•
•
•
Check circuit breaker and reset if necessary.
Ensure the heating/cooling system is powered up.
Ensure the furnace door is properly closed.
Ensure two fresh AAA alkaline batteries are correctly installed.
Temperature settings cannot be
changed.
•
•
The System switch is off.
You are setting the temperatures outside their allowable ranges:
•
•
Heat: 40 °F to 90 °F (4.5 °C to 32 °C).
Cool: 50 °F to 99 °F (10 °C to 37 °C).
Cool On or Heat On is flashing.
•
The compressor protection delay has been activated. Wait for the
delay to end (maximum of 5 minutes).
HI appears on the screen.
LO appears on the screen.
E1 appears on the screen.
E2 appears on the screen.
•
•
•
•
The ambient (measured) temperature is above 122 °F (50 °C).
The ambient (measured) temperature is below 32 °F (0 °C).
The temperature sensor circuit is opened. Replace the thermostat.
The temperature sensor circuit is shorted. Replace the thermostat.
9
| General | Details |
|---|---|
| Name | Honeywell PRO 1000 Series Heat Pump Thermostat Instruction Manual |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.59 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell D1-528 Direct Thermostat Installation Guide

Honeywell FocusPRO P200 Programmable Thermostat User Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide