Room  
Temperature  
OPENWINDOWDETECTIONFEATURE  
WARRANTY CONDITIONS  
1-The warranty period starts from the invoice date and warranted against  
manufacturing defectsfor 2 years.  
WARRANTY CERTIFICATE  
22.5oC  
22.0oC  
21.5oC  
If a window is left open, cold air will enter and the temperature in the room will drop  
rapidly. In cooling systems, hot air will enter and the temperature in the room will  
rise rapidly. The Room Thermostat, which detects this situation, tries to keep the  
room temperature at the desired level by operating the heating or cooling system  
more. The open window detection feature allows the Room Thermostat to operate  
the heating/cooling system more efficiently in case the temperature in the room  
dropsor risesrapidly.  
This featureis used to saveenergyand to ensuremoreefficient operation of heating  
and ccoling systems. Thanks to the open window detection feature, unnecessary  
energyexpenditureis preventedand allows theuser to saveenergycosts.  
When the Room Thermostat is in heating mode and the Open window detection  
feature is active, if it detects a sudden drop in room temperature up to the degree  
adjusted in the Set menu (factory setting 5oC) within 15 minutes, it switches to  
alarm status, the open window icon flashes on the display of the Room Thermostat  
and switches off the heating/cooling unit. The heating/cooling unit remains off for  
the time adjusted in the Run Menu. If the Room Thermostat detects that the window  
is closed or if a manual intervention is made on the Room Thermostat, the detection  
is deactivated and heating/coolin unit continues to operate from where it left off. If  
a sudden drop in ambient temperature is detected again, the Room Thermostat  
goes into alarmstatus.  
Set  
Temperature  
2-Devices and apparatus are delivered to the customer in working condition in our  
company. On-sitecommissioning is subjectto aservice fee.  
Manufacturer  
Heating  
Unit On  
Title: ISIPARK İÇ DIŞ TİC. A.Ş.  
Adress: Fatih Mah. 1188 Sk. No:13/A Sarnıç Gaziemir İzmir-TÜRKİYE  
Tel: +90 (232) 457 99 50  
3-The repair of the devices and apparatus covered by the warranty is carried out in  
our company factory and should send bycontracted transportation company. In on-  
site services, the transportation and accommodation expenses of the service  
personnel belong to the customer. The shift fee during transportation is added to  
theservice feeand collectedin advance.  
Fax: +90 (232) 457 91 22  
Heating  
Unit Off  
Time  
E-mail: generallife@generallife.com.tr  
Authorized Signature:  
CoolingMode  
4-The maintenance of devices and apparatus is done in our company. For the  
maintenance of the devices and apparatus, the round travel fares belongs to the  
customer.  
Company Stamp:  
Your Room Thermostat takes the average room temperature of last 40 seconds as  
basis. If the room temperature goes above the hysteresis positive temperature  
value you set, your Room Thermostat will start the cooling unit. If it goes below the  
hysteresis negative temperature value, your Room Thermostat will stop the cooling  
unit. Thus, itensuresthattheroomtemperatureremainswithin acertain range.  
5-In case of malfunctioning of the devices and apparatus whose warranty period  
continues, it is tested in our company whether the malfunction is caused by a  
customer or manufacturer fault, and it is reported with a report issued by our  
company.  
Room  
Temperature  
Product  
Type: Smart Room Thermostat  
Brand: GENERAL Life  
6-In case of detection of manufacturer-induced errors of devices and apparatus  
whose warranty period continues, the customer can request a replacement or  
repair of the devices and apparatus at full expense by the manufacturer, unless it's  
higher than theproduct's price  
22.5oC  
22.0oC  
Set  
Temperature  
21.5oC  
If the Room Thermostat is operated in cooling mode, the sudden temperaturerise in  
taken to consideration.  
This featureis activein factory setting.  
Itcan be deactivatedfromtheRoom Thermostatsettings.  
To deactivatetheopen window detectionfeature:  
Model: HT25 SMART/HT25S SMART  
Warranty Period: 2 Years  
Max. Time to Repair: 20 Days  
Bandrol and Serial Number:  
7-In the event that the faults of the devices and apparatus whose warranty period  
continues are determined as caused by the customer, all expenses would be belong  
to thecustomer.  
Cooling  
Unit On  
PresstheON/OFFbutton for 3 seconds while yourdeviceis turned off.  
PresstheON/OFFbutton until the menu appears.  
While in the menu, turn thebutton to left. The “ ” option willappear.  
To savethesettingsand exit, presstheON/OFFbutton until thedeviceturns off.  
The settings you have made are saved. Your device will work with the setting you  
8-Customers should be aware of damages (if there is any) of product and warn  
manufacturer since the day warranty duration starts.If customer do not warn  
manufacturerwithknowledge of damage, customerlose therights of article 6.  
9-Malfunctions resulting from the use of devices and apparatus contrary to the  
mattersstatedin theUserManual arenot coveredbythewarranty.  
10-Devices and their apparatus are out of warranty if they are beaten, broken or  
scratchedbythecustomer.  
Cooling  
Unit Off  
Time  
Your Room Thermostat sends the last status signal to the Receiverevery3 minutes.  
Thus, yourRoom Thermostat and Receiverwork synchronously. If the signal cannot  
reach to the Receiver from the Room Thermostat for 22 minutes, it perceives that  
the connection is broken and stops the heating/cooling operation for safety  
reasons. Likewise, in cases where the electricity comes back after a power failure,  
the Receiver do not operate the heating/cooling unit until 'operate' signal reaches  
fromtheRoom Thermostat.  
havemade when youopen it.  
Heating/Cooling Unit  
Off  
On  
On  
Room  
Temperature  
11-Damages resulting from the use of devices and apparatus belonging to other  
brands and models without the approvalof the manufacturer are not coveredby the  
warranty.  
22oC  
However, in this case, if the Room Thermostat continues to operate normally, it will  
continue to work properly without any need for intervention since it sends a status  
signal to theReceiverevery3 minutes.  
12-Battery leakage and errors due to rust, oxidation and liquid contact by working in  
acidic/ humid environmentsarenot coveredbythewarranty.  
17oC  
13-When the product is not used for a long period (more than 15 days), remove the  
batteries. Otherwise, malfunctions thatwilloccur areout of warranty.  
14-Damages that may occur during the transportation of devices and apparatus are  
not coveredbythewarranty. Customers can takeatransportation insurance.  
15-Damages caused by mains voltage / faulty electrical installation are not covered  
bythewarranty.  
Time  
FREQUENTLY ASKEDQUESTIONS  
15 min.  
25 min.  
40 min.  
IsmyRoom Thermostatcompatible withmyheating/cooling unit?  
OPENWINDOWDETECTIONOPERATIONSETTINGS  
- SETMENU  
SetMenu allows youto set the value of the sudden temperature change (celsius)  
required for your Room Thermostat to activate the open window detection feature.  
The factory setting of the required sudden temperature change value is 5oC. This  
valuecan be adjusted between2oC and 10oC.  
If your heating / cooling unit has on-off connections, your Room Thermostat is  
compatible. You can find information about your heating / cooling unit from your  
heating / cooling unit operating manual or fromyourheating / cooling unit service.  
Vendor  
Title:  
16-Devices and apparatuses are out of warranty for malfunctions caused by force  
majeuresuch asre, flood, earthquakeetc.  
How willIconnect myheating/cooling unit withmy Receiver?  
We recommend that the connection between the Receiver and heating/cooling unit  
should be made byprofessionally qualified persons.  
17-All of the devices and apparatuses, including all their parts, are under the  
warrantyof our company.  
Adress:  
To change theopen window operating temperature:  
2x0.75mmcableis sufficientfor theReceiverheating/cooling unit connection.  
Connect one end of the cable pair to the room thermostat connection terminals  
statedin theuser manual of yourheating/cooling unit.  
Pressand hold thebutton for 3 seconds while thedeviceis switchedoff.  
Pressthebutton until the menu appears.  
In the “ ” menu that appears, adjust the operating temperature by turning the  
18-In case of malfunction of the devices and apparatuses within the warranty  
period, the time spent during repairment period is added to the warranty period. The  
repair period of the product cannot exceed 20 working days. This period starts from  
the date of notification to the service station of the malfunction related to the  
Tel:  
Fax:  
E-Mail:  
button to theright or left.  
Connect the other end of the cable pair to COM and NO inputs of the terminal inside  
theReceiverasshown in the"RECEIVERWIRINGDIAGRAM" section.  
The directionof thecableends does not matter.  
Invoice Date and Number:  
Delivery Time and Place:  
Authorized Signature:  
Company Stamp:  
To savethesettingsand exit, pressthebutton until thedeviceswitches off.  
The settings you have made have been saved. Once you turn on your device, it will  
operatewiththechanged settings.  
product or, in the absence of  
a
service station, to the seller, dealer, agency,  
representative, importer or manufacturer of the product. Consumer can report the  
problem by; phone, fax, e-mail, registered and reply paid letter or a similar way.  
However, in case of a conflict, responsibility of prove is belong to the customer. If  
the malfunction of the product is not repaired within 20 working days, the  
manufacturer-producer or importer; has to allocate another product with similar  
featuresto theuse of theconsumer until therepairof theproductis completed,  
19-Although theconsumer uses his/her repairrights,  
DECLARATIONOFCONFORMITY  
- RUN MENU  
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which Head Office  
and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç - Gaziemir -  
İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its  
specificationsbelow is coveredbytheprovisionsof thementioned directive.  
Run Menu allows you to set the off time of the heating/cooling unit while the open  
window detection feature of your Room Thermostat is active. The factory setting  
for off timeis 10minutes.  
Product  
Type: Smart Room Thermostat  
Brand: GENERAL Life  
To settheoff time:  
Brand  
: GENERAL Life  
Pressand hold thebutton for 3 seconds while yourdeviceis switchedoff.  
Pressthebutton until the menu appears.  
Set the operating time of the open window detection featureby turning the button  
to theright or leftin the menu.  
To savethesettingsand exit, pressthebutton until thedeviceswitchesoff.  
The settings you have made have been saven. Once you turn on your device, it will  
operatewiththechanged settings.  
-If the product breaks down for 4 times in a year or 6 times in warranty duration and  
theseproblemseffectsmain purpose of theproduct.  
ProductName : HT25 SMART/HT25S SMART  
Model: HT25 SMART/HT25S SMART  
STAMP  
ProductType : Smart Room Thermostat  
(starting fromdelivery timeduring warranty.)  
The product manufactured by ISIPARK and mentioned above is connected  
wirelessly at 2.4 Ghz internet and periodically shares the temperature and status  
information withtheserver on theinternet.  
- Exceedingthemaximum timerequiredfor repair,  
- In the event that the service station is not available, if it is determined that the  
repair of the defect is not possible with the report prepared (in order) by one of the  
seller, dealer, agency, representative, importer or manufacturer, a refund or a price  
discount attherateof defectcan be requested.  
Compatible Directives:  
Radio and Telecommunications TerminalEquipmentRegulation  
2014/53/EU(ETSI EN301489-1 V2.2.3(2019-11),  
FACTORY SETTINGS RESET  
You can reset your Room Thermostat to its default factory settings. This operation  
resets the calibration setting, heating/cooling modes and hysteresis settings to  
factory setting. To resetyourRoom Thermostatto factory setting:  
20-The customer can make complaints and appeals to consumer courts or  
consumer arbitrationcommittees.  
ETSI EN301489-17 V3.2.4(2020-09), EN300220-1V3.1.1,  
EN300220-2V3.2.1(2018-06), EN62479:2010, EN62368-1:2014+A11:2017)  
Electromagnetic Compatibility Regulation 2014/30/EU  
(ETSI EN301489-1 V2.2.3, ETSI EN301489-3 V2.1.1)  
21-The warranty document must be kept by the customer during the warranty  
period. If the document is lost, a second document will not be issued. In case of  
loss, repairand replacementof devicesand apparatus willbe made for afee.  
While yourdeviceis turned off, pressand hold thebutton for 3 seconds.  
Pressthebutton until the menu appears.  
While in the “ “ menu, turn the button to right or left in order to select “  
Low Voltage Directive2014/35/EU(EN60730-2-9)  
Supplementary Information: Mentioned product can be used with combi boilers  
with on / off output and compatibility with the directive only covers the product.  
ISIPARK is not responsible for the compliance of the entire system with the  
directive. This declaration does not apply when changes are made to the product  
without obtaining our consent.  
option and pressthebutton.  
Your devicewillbe turned off and resetto factory settings.  
ISIPARKreservestherights of changing productspecificationsand user manuals.  
*For allchanges, youmayvisitgenerallife.com.tr  
ROOMTHERMOSTATWORKINGLOGIC  
Heating Mode  
Your room thermostat takes the average room temperature of last 40 seconds as  
basis. If the room temperature goes above the hysteresis positive temperature  
value you set, your Room Thermostat will stop the heating unit. If it goes below the  
hysteresisnegativetemperaturevalue, yourRoom Thermostat will start the heating  
unit. Thus, itensuresthattheroom temperatureremainswithin acertain range.  
5
6
7
8
GeneralDetails
NameGENERAL LIFE Mitra Series Smart Room Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.1 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE Mitra Series Smart Room Thermostat User Manual