Home > GENERAL LIFE > GENERAL LIFE MITRA 260S RF Room Thermostat User Manual
GENERAL LIFE MITRA 260S RF Room Thermostat User Manual
WARRANTY CONDITIONS
1-The warranty period starts from the invoice date and warranted against
manufacturing defectsfor 5 years.
WARRANTY CERTIFICATE
ROOM THERMOSTAT HYSTERESIS NEGATIVE MENU
Your Room Thermostat sends the last status signal to the Receiver every
10 minutes. Thus, your Room Thermostat and Receiver work
synchronously. If the signal cannot reach to the Receiver from the Room
Thermostat for 22 minutes, it perceives that the connection is broken and
stops the heating/cooling operation for safety reasons. Likewise, in
cases where the electricity comes back after a power failure, the Receiver
do not operate the heating/cooling unit until 'operate'signal reaches from
theRoom Thermostat.
Hysteresis negative factory setting of your room thermostatis -0.5°C.
This value may be adjusted between “-0.1°C” and “-2.0°C”. While
hysteresis negative value is -0.5°C, if the room temperature goes
below 0.5°C of set temperature, your room thermostat will send a
signaltoyourheating/coolingunit.
2-Devices and apparatus are delivered to the customer in working condition in
our company. On-sitecommissioning is subjectto aservice fee.
3-The repair of the devices and apparatus covered by the warranty is carried
out in our company factory and should send by contracted transportation
company. In on-site services, the transportation and accommodation
expenses of the service personnel belong to the customer. The shift fee during
transportation is added to theservice feeand collectedin advance.
4-The maintenance of devices and apparatus is done in our company. For the
maintenance of the devices and apparatus, the round travel fares belongs to
thecustomer.
Manufacturer
Title: ISIPARK İÇ DIŞ TİC. A.Ş.
Adress: Fatih Mah. 1188 Sk. No:13/A Sarnıç
Gaziemir İzmir-TÜRKİYE
For instance, when you set your room thermostat to 22°C, if the room
temperature goesbelow21.5°C,onheatingmodeyourheatingunitwill
start working; on cooling mode your cooling unit will stop working. In
ordertochangethehysteresisnegativesetting:
Tel: +90 (232) 457 99 50
However, in this case, if the Room Thermostat continues to operate
normally, it will continue to work properly without any need for
intervention since it sends a status signal to the Receiver every 10
minutes.
Fax: +90 (232) 457 91 22
E-mail: generallife@generallife.com.tr
Authorized Signature:
Pressthebutton for 3 seconds whileyourdeviceis off.
Company Stamp:
Pressthebutton until “
Adjust the operating sensitivity by turning the button to the left or
right in the“ “ hysteresisnegativemenu.
“ menu appears.
5-In case of malfunctioning of the devices and apparatus whose warranty
period continues, it is tested in our company whether the malfunction is
caused by a customer or manufacturer fault, and it is reported with a report
issued byour company.
FREQUENTLY ASKED QUESTIONS
IsmyRoom Thermostatcompatible withmy heating/cooling unit?
Pressthebutton until deviceturns off to savethechanges and exit.
Changes have been saved. Your room thermostat will be working
withthesetoperating sensitivitywhen youopen yourdevice.
If your heating / cooling unit has on-off connections, your Room
Product
6-In case of detection of manufacturer-induced errors of devices and
apparatus whose warranty period continues, the customer can request a
replacement or repair of the devices and apparatus at full expense by the
manufacturer, unless it's higher than theproduct's price.
Thermostat is compatible. You can find information about your heating /
cooling unit from your heating / cooling unit operating manual or from
yourheating / cooling unit service.
Type: Digital Room Thermostat
Brand: GENERAL Life
Model: HT250 RF
FACTORY SETTINGS RESET
How willIconnect myheating/cooling unit withmyReceiver?
7-In the event that the faults of the devices and apparatus whose warranty
period continues are determined as caused by the customer, all expenses
would be belong to thecustomer.
Warranty Period: 5 Years
Max. Time to Repair: 20 Days
Bandrol and Serial Number:
You can reset your Room Thermostat to its default factory settings.
This operation resets the calibration setting, heating/coling modes
and hysteresis settings to factory setting. To reset your Room
Thermostatto factory setting:
We recommend that the connection between the Receiver and
heating/cooling unit should be madebyprofessionally qualified persons.
2x0.75 mm cable is sufficient for the Receiver – heating/cooling unit
connection.
8-Customers should be aware of damages (if there is any) of product and warn
manufacturer since the day warranty duration starts.If customer do not warn
manufacturerwithknowledge of damage, customerlose therights of article 6.
9-Malfunctions resulting from the use of devices and apparatus contrary to the
mattersstatedin theUserManualarenot covered bythewarranty.
10-Devices and their apparatus are out of warranty if they are beaten, broken or
scratchedbythecustomer.
Connect one end of the cable pair to the room thermostat connection
terminalsstatedin theusermanual of yourheating/cooling unit.
Connect the other end of the cable pair to COM and NO inputs of the
terminal inside the Receiver as shown in the "RECEIVER WIRING
DIAGRAM" section.
While your device is turned off, press and hold the button for 3
seconds.
Pressthebutton until the“
While in the “ “ menu, turn the button to right or left in order to
select“ “ option and pressthebutton.
” menu appears.
11-Damages resulting from the use of devices and apparatus belonging to
other brands and models without the approval of the manufacturer are not
covered bythewarranty.
The direction of thecableends does not matter.
Your devicewillbe turned off and resetto factory settings.
DECLARATION OF CONFORMITY
ROOM THERMOSTAT WORKING LOGIC
HeatingMode
12-Battery leakage and errors due to rust, oxidation and liquid contact by
working in acidic/ humid environments arenot covered bythewarranty.
13-When the product is not used for a long period (more than 15 days), remove
thebatteries. Otherwise, malfunctions thatwilloccur areout of warranty.
14-Damages that may occur during the transportation of devices and
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which
Head Office and production site is located on Fatih Mah. 1188
Sk.No:13/A Sarnıç - Gaziemir - İZMİR – TÜRKİYE confirms and declares
that the product marked with CE and its specifications below is covered
bytheprovisionsof thementioned directive.
Your room thermostat takes the average room temperature of last 40
seconds as basis. If the room temperature goes above the hysteresis
positive temperature value you set, your Room Thermostat will stop
the heating unit. If it goes below the hysteresis negative temperature
value, your Room Thermostat will start the heating unit. Thus, it
ensuresthattheroom temperatureremainswithin acertain range.
Vendor
Title:
apparatus are not covered by the warranty. Customers can take
transportation insurance.
a
Brand
: GENERAL Life
Product Name : HT250 RF
15-Damages caused by mains voltage / faulty electrical installation are not
covered bythewarranty.
Product Type : Digital Room Thermostat
Adress:
Compatible Directives:
16-Devices and apparatuses are out of warranty for malfunctions caused by
forcemajeuresuch asfire, flood, earthquakeetc.
Room
Temperature
Radio and Telecommunications Terminal Equipment Regulation
2014/53/EU(R&TTE/RED EN301489-1 V2.1.1:2017,
EN300220-1V3.1.1:2017, EN301489-3 V2.1.1:2017,
EN300220-2V3.1.1:2017, EN62479:2010)
Tel:
Fax:
17-All of the devices and apparatuses, including all their parts, are under the
warrantyof our company.
22.5oC
E-Mail:
Set
Temperature
21.5oC
22.0oC
Invoice Date and Number:
Delivery Time and Place:
Authorized Signature:
Company Stamp:
18-In case of malfunction of the devices and apparatuses within the warranty
period, the time spent during repairment period is added to the warranty period.
The repair period of the product cannot exceed 20 working days. This period
starts from the date of notification to the service station of the malfunction
related to the product or, in the absence of a service station, to the seller, dealer,
agency, representative, importer or manufacturer of the product. Consumer
can report the problem by; phone, fax, e-mail, registered and reply paid letter or
a similar way. However, in case of a conflict, responsibility of prove is belong to
the customer. If the malfunction of the product is not repaired within 20
working days, the manufacturer-producer or importer; has to allocate another
product with similar features to the use of the consumer until the repair of the
product is completed,
Electromagnetic Compatibility Regulation 2014/30/EU
(EMCEN61000-6-3:2007+ A1:2011, EN61000-6-1:2007)
Low VoltageDirective2014/35/EU
Heating
Unit On
Heating
Unit Off
(LVD EN60730-2-9:2010, EN60730-1:2011)
Time
Additional Information: The mentioned product can be used with
heating/cooling units with on / off output and compliance with the
directives only covers the product. ISIPARK is not responsible for the
entire system's compliance with the directives. This statement is not
validif changes aremadeto theproduct without our approval.
Product
CoolingMode
Type: Digital Room Thermostat
Brand: GENERAL Life
Model: HT250 RF
STAMP
Your Room Thermostat takes the average room temperature of last
40 seconds as basis. If the room temperature goes above the
hysteresis positive temperature value you set, your Room
Thermostat will start the cooling unit. If it goes below the hysteresis
negative temperature value, your Room Thermostat will stop the
cooling unit. Thus, it ensures that the room temperature remains
within acertain range.
19-Although theconsumer uses his/her repairrights,
-If the product breaks down for 4 times in a year or 6 times in warranty duration
and these problems effects main purpose of the product. (starting from
delivery timeduring warranty.)
-Exceeding themaximum timerequired for repair,
-In the event that the service station is not available, if it is determined that the
repair of the defect is not possible with the report prepared (in order) by one of
the seller, dealer, agency, representative, importer or manufacturer, a refund or
apricediscount attherateof defectcan be requested.
Room
Temperature
22.5oC
22.0oC
Set
Temperature
21.5oC
20-The customer can make complaints and appeals to consumer courts or
consumer arbitrationcommittees.
Cooling
Unit On
ISIPARK reserves the rights of changing product specifications and
usermanuals.
21-The warranty document must be kept by the customer during the warranty
period. If the document is lost, a second document will not be issued. In case of
loss, repairand replacementof devicesand apparatuswill be made for afee.
*For allchanges, youmayvisitgenerallife.com.tr
Cooling
Unit Off
Time
5
6
7
8
| General | Details |
|---|---|
| Name | GENERAL LIFE MITRA 260S RF Room Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.22 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual